Publish Time:2023-10-25        View Count:197         Return to List

How to Select an Oxidation Ditch Low-Speed Impeller

Selection Methods for Submersible Flow Pumps

Diving Propulsion DeviceComplete set, including installation system and lifting device. The installation system should consist of square steel guide rods and top and bottom supports, allowing for free adjustment of the pusher's lifting and lowering. The flow controllers can be disassembled and installed without draining the pool. The flow controllers are mounted on a bracket that slides along the guide rod, acting as a single unit. The bracket must be able to bear the entire weight of the flow controller and all the thrust it generates.

The lifting device should be portable, and the hoisting frame's mounting device must not be installed on the pool wall or the poolside work platform. It should be mounted on the top support of the installation system, and should include a stainless steel lifting hook, lifting chain, and pulley.

Each streamer should be provided with a cable tensioning component and a cable clip to prevent cable damage caused by fluctuations in the stirred water flow.

Lifting arms equipped with mounting brackets and lifting devices should be made of AISI 304 stainless steel. The lifting chain should be of AISI 316 stainless steel material. Bolts, nuts, washers, rotating handles, and anchor bolts should also be supplied as a set. Anchor bolts must be installed using chemical bolts to ensure a secure and durable installation of the flow controller system; expansion bolts are not to be used.

Submersible flow propellers should be capable of adapting to the corrosive environment of municipal wastewater. They must be able to propel wastewater or sludge flow. Ensure Bottom Flow RateApologies, but there is no Chinese content provided to translate. Please provide the text you would like translated into American English. 300mm as standardNot less than 0.3m/sThe streamer should operate continuously under full immersion conditions. It should also be adaptable to both continuous and intermittent operation.(Increased startup frequency per hourTo be achieved 20 times)The status of resuming operations after a long-term shutdown.

Submersible low-speed flow generators must operate smoothly without vibration. All rotating components (including the motor) should undergo dynamic and static balance tests during manufacturing. The flow generator should be cost-effective for operation and maintenance, highly reliable, and have a long period of trouble-free operation.

Parts Material for Submersible Flow InjectorPropeller: Reinforced Polyurethane

Gearbox: Cast Iron DIN1691 GG25 (ASTM A48 35B)

Motor Shell: Cast Iron DIN1691 GG25 (ASTM A48 35B)

Axle: Stainless Steel

Mechanical Seals: Silicon Carbide/Silicon Carbide Fasteners: Stainless Steel AISI 316 Cable Sheath: Chloroprene Rubber

O-Ring: Nitrile or Fluororubber; Flowmeter Bracket: Stainless Steel AISI 304

Guide Rail System: Stainless Steel AISI 304

Improved Steel Cable: AISI 3164 Stainless Steel

Enhance Lifting Device Boom: Stainless Steel AISI 304

Chemical Anchor Bolts: Stainless Steel

    

Duwan Environmental's QJB Submersible Propeller Driver Major Components

Fully assembled submersible propellerMainframe

(2) Accompanying dive motor;

(3) Complete installation system (guideways, brackets, cable tensioners, etc.)

(4) A lifting system (including a mobile lifting bracket, a lifting pulley, stainless steel lifting chains, and hooks, etc.).

Each streamer comes with a submersible cable.

(6) The streamer protection components include leak protection, temperature protection, and protection controllers, etc.

All connection accessories, all fasteners required for installation (including stainless steel anchor bolts, nuts, washers, etc.).

(8) Two years of spare parts and accessories covered under warrantyBackup Tools.

Duwan Environmental Submersible Flow Pumps and Bracket Systems supply, including all brackets and accessories, along with comprehensive installation and commissioning until they operate normally. The buyer receives a fully operational submersible flow system.

Selection of oxidation ditch flow diverters is based on parameters such as pond length, width, depth, and medium depth.

   