Environmental equipment, instruments and meters, robots, ...

Section 1: Safety Rules and Precautions
Prior to using the digital large-area earth ground resistance tester, please strictly adhere to the following safety rules and precautions to ensure a smooth testing process and the safety of personnel:
Instrument Design and Safety Standards: This instrument is designed in accordance withIEC61010Safety specifications should be strictly adhered to during use.
Avoid using mobile phones and other high-frequency signal generators near the instrument during measurements to prevent errors.
Instrument Inspection: Before use, ensure that the instruments and accessories are in good condition, and check for any damage, exposure, or broken wires in the test line insulation.
Ensure all wire connection plugs are securely inserted into the instrument interface before measurement.
Test Process Stability: Avoid shaking the test cable or sudden disconnection or short-circuiting during testing to ensure the accuracy of the measurement results.
Avoid Electric Shock: Do not touch bare conductors or the circuit under measurement during the testing process to prevent electric shock.
Be aware of electric sparks: Sparks may occur when plugging or unplugging test wires or power outlets, so keep a safe distance from flammable items.
Do not store the instrument for extended periods in high humidity, areas with condensation, or under direct sunlight.
Power On/Off Precautions: Avoid frequent power on/off operations; there should be5~10One-second buffer time.
Power Supply Environment: Please use220V/50HzEnsure that the power strip's current capacity exceeds when using extension cords for power supply.15A。
Authorization Required: The use, disassembly, calibration, and repair of this instrument must be performed by authorized personnel only.
Safety Warning Signs: Please operate strictly according to the safety warning signs indicated on the instruments and manuals.
Section II: Product Introduction
The Digital Large Ground Resistance Tester is a high-precision, fast, and stable measuring instrument suitable for grounding resistance tests in various environments such as telecommunications, electricity, meteorology, data centers, and oil fields. It employs a new type of variable-frequency AC power supply, dual-frequency measurement technology, and microprocessor technology, featuring precise, rapid, simple, and reliable measurements.
This tester boasts powerful functions, capable of measuring two-line, three-line, and four-line test impedances, as well as soil resistivity, step voltage, distributed potential, contact voltage, and current phase angles. Its output high open-circuit voltage can reach400VNo Chinese content provided.5AMeets various testing requirements.
Additionally, this testing instrument features a large-screen display, data storage, historical data retrieval, review, save, and print capabilities, making the testing process more convenient and efficient.

How to Use
Preparation: Connect the test line, grounding rod, and other accessories, ensuring all connections are secure and reliable.
Power On: Press the power switch on the instrument panel and wait for the instrument to initialize.
Select Test Mode: Choose the appropriate test mode based on your testing requirements (such as secondary, tertiary, or quaternary testing, etc.).
Initiate Testing: Connect the test line to the ground grid to be tested and ensure good contact between the test line and the ground grid. Press the test button and wait for the test to complete.
Upon completion of the test, the instrument will display the test results. You can view them on the large screen or print out the test data via the printer.
Shut Down and Save: After completing the test, press the power-off button to turn off the instrument. If needed, you can save the test data to the instrument's internal or external storage device.
Four: Maintenance and Care
Regular Cleaning: Regularly clean the instrument housing and test lines to keep them dry and clean.
Store the instrument in a dry, well-ventilated, dust-free environment, avoiding direct sunlight and high temperatures.
Regular Calibration: Regularly calibrate instruments to ensure accuracy of their measurements.
Please follow the guidelines for using the digital large ground resistance tester. In case of any questions or malfunctions, please contact customer service promptly.
www.114global.com © Zhongshang 114 Hebei Network Technology Co., Ltd.Address: Room 6009, Oriental New World Center, No.118 East Zhongshan Road, Qiaoxi District, Shijiazhuang City, Hebei ProvincePlatform Service Hotline: 4006299930