价 格Negotiable
最小起订0 Piece库存0 Piece
Japan Magnescale Digital Indicato
Negotiable
Shoufeng VMS-5040 Automatic Image
Negotiable
Japanese Magnescale Displacement
Negotiable
Mitutoyo Sanwa Three-Jaw Quick-Ac
Negotiable
Japanese Magnescale Probe Sensor
Negotiable
Mitutoyo Sensitive Micrometer Cal
Negotiable
Japanese Magnescale Digital Indic
Negotiable
Japanese Magnescale Displacement
Negotiable
Mitutoyo SAE Micro Hole ID Gauge
Negotiable
Japan Magnescale Magnet Scale SJ7
Negotiable
Japan Magnescale Digital Indicator LH70-3

Milling and lathe counters
Display Resolution Switch
Machine Error Compensation
Data Storage
Reset/Default
Original Point Measurement Component Calibration
Programming Features
Multiple benchmark points
Milling Machine Features (Bolt Hole Perimeter / Simple R Profiling / Linear Holes)
Lathe Specifications (Tool Coordinate / Accumulation Function)
| Key Specifications | |||
|---|---|---|---|
| Model | LH70-1 | LH70-2 | LH70-3 |
| Display | Display 7-digit numbers and negatives | ||
| Connectable measurement component | GB-ER, PL20C, SJ700A (Direct) / DG-B ( Requires an additional conversion adapter) | ||
| Measurement Component Input Resolution | Standard: 0.1μm, 0.5μm, 1μm, 5μm, 10μm, 1s, 10s, 1min, 10min Expansion: 100μm, 50μm, 25μm, 20μm, 2μm, 0.05μm; can add 1 degree | ||
| Display Resolution | Measurement component input resolution or higher, including double display (except angle display) | ||
| Input Signal | A/B phase (pulsed) signal, Z phase (conforming to EIA-422) | ||
| Small input phase difference | 100ns | ||
| Quantized error | ±1 count | ||
| Alert displayed | Length measuring component not connected, overspeed, exceeded large display limit, power failure, error saving data | ||
| Reset | Reset via push-button switch | ||
| Pre-set | Save/Call 3 Types of Values | ||
| Origin Detection Function | Origin detection for length measurement component | ||
| Data Storage | Preserve display values and various settings during power outages | ||
| Linear Compensation | Compensate the count value for the length measuring component by a certain amount. Compensation Quantity Standard: ±600um/m (Extended: ±1000um/m) | ||
| Programming |
| ||
| Sleep Mode | If there is no activity within a specified time frame, the display will disappear (time can be set). | ||
| Power Supply | DC 12V, rated 0.75A, max. 1A, AC 100~240V ±10% When using the AC adapter PSC-23A (for Europe and other countries) *Optional | ||
| Power Consumption | Max. 32VA (Connected to AC adapter) | ||
| Operating Temperature Range | 0 ~ 40°C (No condensation allowed) | ||
| Temperature Range for Storage | -20 to 60°C (No condensation allowed) | ||
| Quality | Approximately 1.5 kg | ||
| Choose LH70 General Application or Milling Machine specification (set to "general" in the basic model selection mode) | |||
|---|---|---|---|
| Model | LH70-1 | LH70-2 | LH70-3 |
| Axle Display | 1 shaft | 2 shafts | 3-axis |
| Multiple benchmark points | 10 | ||
| Bolt hole circumference | – | Display coordinates for drilling holes at equal intervals on a circle with a given diameter. | |
| Simple R-Processing | – | Display coordinates of simple R processing points | |
| Threaded hole | – | Show coordinates for evenly spaced drilling on the line | |
| Choose the LH70 lathe specifications (set "lathe" in the basic model selection mode) | |||
|---|---|---|---|
Magnescale reserves the right to change product specifications without prior notice. | |||
| Model | LH70-3 | ||
| Display shaft | 2-axis display (2-axis or 3-axis input) | ||
| Tool Positioning | 12 | ||
| Measurement Component Input Addition 2 | It features 2-axis addition display. | ||
| Display Maintained | Maintain displayed value and input tool coordinates | ||

Phone Consultation