Ensure These Preparations Are Made Before Installing Linear Guides
Machine level calibration.
Place two equal-height blocks and a marble level ruler on the installation base, then adjust the base level using a precise level instrument.
The requirement is for the base to be convex (2~3 notches).
2, Inspection of the roughness, flatness, straightness, and appearance of the linear guide installation base surface.
Upon completion of the horizontal alignment, it is mandatory to measure the main linear guide rail mounting surface using a laser interferometer (which we typically refer to as the one nearest to...).
The straight guide rail surface on the right pillar (acting as the guide rail) allows for a flatness of 0.05mm per 10m, with the full travel linear accuracy permitted.
Rise: 0.03mm. Roughness requirement: 1.6, no casting defects in appearance.
3. Chamfer treatment for the base surface of linear guide installation and the chamfered installation surface of the guide side benchmark.
The chamfer radius must be no more than 3.5mm. In case of oversized or protruding chamfers, it should be promptly handled with oilstones and files.
Otherwise, it could lead to poor installation of the guide rail precision or interfere with the slider.
The machining of locking thread holes on the base surface for linear guide rail installation.
Ensure the correct positioning of the bolt hole, with the center distance between interconnected bolt holes being greater than or equal to 120mm and less than 0.1mm; to ensure
High-precision screw hole processing requires the use of CNC equipment for positioning and machining.
Inspection of the linear guide rail after unpacking.
Inspect the linear guide for a valid certificate, for any damage or rust, clean the rust-preventing oil thoroughly, and remove any assembly surface debris.
The burrs, impact bumps, and debris.