    Before reusing the de-ironing equipment after a long-term shutdown, the following checks should be performed:

    Electrical Performance Inspection:

    Inspect the electrical performance of the motors and coils to ensure they are in good condition.

    Measure insulation resistance to ensure compliance with usage requirements and prevent electrical failures.

    Mechanical Component Inspection:

    Inspect all connecting components for looseness or damage, including flanges, end caps, and blast-proof surfaces, ensuring they are securely fastened and meet specifications.

    Inspect bearings, lubrication systems, and transmission components to ensure they are operating smoothly and adequately lubricated.

    Appearance and Cleanliness Inspection:

    Clean the surface and interior of the de-ironing device, removing dust and debris to ensure the equipment is clean.

    Inspect equipment for signs of corrosion, rust, or damage and address them promptly.

    Magnetic Field Intensity Inspection:

    Inspect the magnetic field strength of the de-ironing device to ensure it meets design specifications for optimal de-ironing performance.

    Safety Performance Inspection:

    Ensure proper grounding of equipment to prevent electrical accidents.

    Inspect the integrity of safety devices, such as protective guards and warning signs.

    Operations and Control Inspection:

    Inspect the operation and control systems of the descaling equipment to ensure they are functioning properly and user-friendly.

    Conducting a no-load trial run to observe the equipment's operation and ensure there are no abnormal sounds or vibrations.

    Technical Maintenance:

    It is recommended to conduct a technical inspection for long-term inactive de-ironing equipment, which includes oil replacement, replacement of consumable parts, electrical testing, and performance testing, etc.

    Following the above inspections, it ensures that the iron remover operates smoothly and achieves the expected iron removal effect upon reactivation after a long period of downtime. Additionally, it extends the lifespan of the equipment and reduces maintenance costs.



Contact us

Shandong Lumi Industrial Technology Co., Ltd.
Service Hotline 15263526711
Company Phone 15263526711
Company Address Dong Second Ring Road, Mid-section, Economic and Technological Development Zone, Linqing City, Shandong Province

Message Consultation

 Click OK to indicate that you agree to《Service terms》《Privacy policy》

www.114global.com © Zhongshang 114 Hebei Network Technology Co., Ltd.Address: Room 6009, Oriental New World Center, No.118 East Zhongshan Road, Qiaoxi District, Shijiazhuang City, Hebei ProvincePlatform Service Hotline: 4006299930

 Click OK to indicate that you agree to《Service terms》《Privacy policy》