Halogen-Free, Low-Smoke Flame Retardant Cable_SupplyPro Co., Ltd._Anhui Global Communication Instrument Cable Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Anhui Global Communication Instrument Cable Co., Ltd.

Cable Wires, Instruments and Meters, Communication Cables and Accessories

Consultation Hotline
0550-7512577  13965982658

Product Categories
Home > SupplyPro Co., Ltd. > Halogen-Free, Low-Smoke Flame Retardant Cable
Halogen-Free, Low-Smoke Flame Retardant Cable
品牌: Globalcom Instrument Cables
Conductor cross-section: Array
Product Standards: Refer to standards GB/T12706, GB9330, etc.
Applicable Occasions: Power plants, petrochemical facilities, steel mills, tunnels, paper mills, substation, and electronic computer centers, etc., requiring high flame-retardant standards.
单价: 电议
最小起订Quantity: 100 Rice
供货总Quantity: 100000 Rice
有效期至: 长期有效
最后更新: 2023-04-01 17:43
 
详细Info

Conductor Cross Section: 2-61

Product Introduction:

Halogen-free, low-smoke, flame-retardant cable product standards: Refer to GB/T12706, GB9330, and other standards.

 

1. Halogen-free, Low-smoke flame-retardant cable applications:

Halogen-free, low-smoke flame-retardant cables are suitable for fixed installations in AC power transmission and distribution lines with a voltage level of 1kV and below for power transmission purposes; these cables are mainly used in high flame-retardant requirement environments such as power plants, petrochemicals, steel mills, tunnels, paper mills, substation, and electronic computer centers.

Halogen-Free, Low-Smoke Flame RetardantCable wiresFeatures:

(1) No halogen acid gases emitted.

(2) Low smoke emission.

(3) Produces less corrosive gases.

(4) Excellent flame-retardant properties.

3. Specification Range:

Halogen-free, low-smoke, flame-retardant cross-linked polyethylene insulationElectrical CableSpecifications conform to <35kV and belowCross-linked polyethylene insulated power cable

(2) Halogen-free, low-smoke, flame-retardantControl CableSpecifications comply with cross-linked ethylene insulated and polyvinyl chloride sheathed control cables.

4. Key technical performance of halogen-free, low-smoke, flame-retardant cables:

The flame-retardant performance of the finished cables complies with the requirements of IEC60332-3 standard.

(2) Halogen-free and low-smoke material specifications:

a. Leachate gas release amount (mg/g) is 0.

b. pH value ≥ 4.3.

c. Conductivity μs ≤ 10.

d. Toxicity Index ≤ 5.

(3) Halogen-free, low-smoke flame-retardant materials with an oxygen index of not less than 30.

(4) Finished cables are measured to have a light transmittance of no less than 60% according to IEC 1034 standards.

 

Model                         Name

WDZ-BY Non-Halogen Low-Smoke Flame Retardant Polyolefin Insulated Copper Wire

WDZ-BL - Halogen-free, Low-smoke, Flame-retardant Polyolefin Insulated Wire with Aluminum Core

YWDZ-BY: Copper Core Cross-Linked Polyethylene Halogen-Free Low Smoke Flame Retardant Polyolefin Insulated Wire

YWDZ-BLY - Aluminum-core Cross-linked Polyethylene Halogen-free Low-smoke Flame-retardant Polyolefin Insulated Wire

JWDZ-BYJY - Copper Core Cross-Linked Polyethylene Insulated Halogen-Free Low Smoke Flame Retardant Polyolefin Sheathed Cable

WDZ-BLYJY Aluminum-core Cross-linked Polyethylene Insulated Halogen-free Low-smoke Flame-retardant Polyolefin Sheathed Cables

WDZ-BYJYB - Copper-core Cross-linked Polyethylene Insulated Halogen-free Low-smoke Flame-retardant Polyolefin Sheathed Flat Cable

WDZ-BLYJYB Aluminum-core Cross-linked Polyethylene Insulated Halogen-free Low-smoke Flame-retardant Polyolefin Sheathed Flat Cable

undefined

询价单
 Click submit means you agree to《Service terms》《Privacy policy》

13965982658