Ten-Way Cleanroom Standard?_News Center Co., Ltd._Ten-Way Cleanroom Standard?,Dongguan Hongji Decoration Operation Department_Dongguan Hongji Decoration Operation Department_Zhongshang 114 Industry Resources Network
Dongguan Hongji Decoration Operation Department

Dongguan Hongji Decoration Operation Department, established in 2023, is located in Dongguan City, Guangdong Province, and is a company primarily engaged in architectural decoration, renovation, and other construction businesses. The registered capital of the company is 30,000 RMB.

Service Hotline
18938297851  18906534326


Company Information

Location:Guangdong/Dongguan

会员级别:数字营销4

身份认证:    

我的勋章:  通过中商114认证

Business Card

  • 公司名称Dongguan Hongji Decoration Operation Department
  • 联 系 人杨明友 (先生)
  • 公司电话18938297851
  • 手机号码18906534326
  • Company Address19th Floor, Room 305, North 1st Lane, Lin Village, Tangxia Town, Dongguan City, Guangdong Province

News Category
  • No Category

Contact Information
  • Contact person:杨明友
  • Telephone:18938297851
Home > News Center Co., Ltd. > Ten-Way Cleanroom Standard?
News Center Co., Ltd.
Ten-Way Cleanroom Standard?
Publish Time:2023-03-31        View Count:23        Return to List

The standard for a 100,000-class cleanroom is:

Dust Allowable Count (per cubic meter)

Particle counts of 0.5 micrometers or larger must not exceed 3,500,000, and particle counts of 5 micrometers or larger must not exceed 20,000.

Microbial Allowable Numbers

Colony forming units (CFUs) must not exceed 500 per cubic meter.

Colony count must not exceed 10 per culture dish.

Pressure Difference: Cleanrooms with the same cleanliness level should maintain consistent pressure differences. For adjacent cleanrooms with different cleanliness levels, the pressure difference should be ≥5Pa, and for cleanrooms and non-cleanrooms, it should be ≥10Pa.

When a dust-free workshop of ten thousand levels has no special requirements for temperature and humidity, it is advisable to wear clean work clothes that do not cause discomfort, with the temperature generally controlled at 20-22°C in winter; 24-26°C in summer; with fluctuations of ±2°C. The humidity in the cleanroom is controlled at 30-50% in winter and 50-70% in summer.

Power distribution: The general illuminance value for the main production rooms in dust-free workshops (zones) should be ≥300Lx; the illuminance value for auxiliary studios, personnel and material purification rooms, airlock rooms, corridors, and the like should be 200~300Lx.

Noise Control