Flame-retardant Communication Cable 5*2*0.5ZR-HPVV_供应产品_Tianjin Cable Corporation, First Branch 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》

Product Center

Company Qualification

Tianjin Cable Corporation, First Branch

Business Model:
Location: Guangdong
Contact person:毕润乐 (先生)
Mobile号码:13833441274
Company Address:Biyanma Industrial Zone

Flame-retardant Communication Cable 5*2*0.5ZR-HPVV

供应产品
  • Flame-retardant Communication Cable 5*2*0.5ZR-HPVV

    Hotline:13833441274

    Details Introduction

    Flame-retardant Communication Cable 5×2×0.5 ZR-HPVV Technical Analysis
    I. Model Definition and Structure
    ZR-HPVV‌:
    ZR: Flame Retardant (compliant with GB/T 19666-2019 flame retardant standard)
    HP: Solid polyolefin insulated with copper core (high stability for high-frequency signal transmission)
    VV: Industrial Protective Sleeves (oil, acid and alkali resistant)
    5×2×0.5‌:
    5 pairs: Twisted pair count (supports parallel transmission of multiple signals).
    2×0.5: Each pair contains 2 conductors (single conductor cross-sectional area 0.5mm², copper core diameter approx. 0.8mm).
    Section II: Key Performance Parameters
    Parameters Item Technical Specifications Standard Basis
    Conductor Resistance ≤95Ω/km(20℃) GB/T 3956‌
    Insulation with voltage resistance 1kV/min non-breakdown (thickness ≥ 0.4mm) GB/T 7594.2‌
    Flame Retardancy Rating C Class (Bundled Combustion Test) GB/T 18380-2008‌
    Operating Temperature -30°C to 70°C GB/T 13849‌
    Bend Radius ≥8 times the outer diameter (dynamic laying) YD/T 1019-2013‌
    Section 3: Application Scenarios
    Industrial Communication System: Suitable for distribution lines with rated working voltage of 3kV and below, such as PLC control signal transmission.
    Flame Retardant Requirement Locations: Indoor installations, conduit or cable trenches; must comply with bundle combustion test requirements.
    Complex Environment: Oil-resistant and corrosion-resistant, suitable for harsh environments such as metallurgy and petrochemical industries.
    Section 4: Certification and Laying Requirements
    Mandatory Certification: Must pass GB/T 19666 flame-retardant test and MT 386 coal mine flame-retardant cable test.
    Laying Specifications: Direct burial depth ≥1.2m, tension force ≤80% of short-term tensile strength (≤1500N).

    Tianjin Cable Corporation, First Branch

    Inquiry Message
     Click submit means you agree to《Service terms》《Privacy policy》
    Contact us
    • 毕润乐 (Mr.)

    • 13833441274

    • 13833441274

    • 1301702141@qq.com

    • Biyanma Industrial Zone

    www.114global.com © Zhongshang 114 Hebei Network Technology Co., Ltd.Address: Room 6009, Oriental New World Center, No.118 East Zhongshan Road, Qiaoxi District, Shijiazhuang City, Hebei ProvincePlatform Service Hotline: 4006299930

     Click submit means you agree to《Service terms》《Privacy policy》