1. First, check if the scale body's transmitting antenna and the hook ring's safety pin are properly installed, then place the fully charged scale body's main unit battery inside the scale and plug in the power cord.
Press the start-up button on the gauge, and a weight signal will indicate normal reception. If reception is not normal, only the date and time will be displayed. Please contact the dealer and manufacturer for assistance.
To ensure accurate measurement, the weighing body must be powered on and preheated for 10 minutes before the object can be hung for weighing, after the instrument display has been set to zero.
When weighing an item without tare, make sure the scale's current tare setting is 0kg. The relationship is: Net Weight = Gross Weight - Tare.
5. Under-voltage Indicator: Battery 1 indicates the meter's power, while Battery 2 indicates the scale's power. Please recharge promptly when the battery voltage is insufficient to prevent data loss or inaccurate weighing.
When the scale is not in use for a short period, please turn off the scale using the "Wireless Remote" button on the instrument, then turn off the instrument's power. To turn the scale on, also use the instrument to control the scale's startup. If the scale will not be used for a long time, please remove the scale's battery to prevent over-discharge.
Battery Charging Maintenance: Prohibit over-discharging of batteries (leaving batteries on the scale body for an extended period without charging), and regularly charge unused batteries or instruments (once a month).