产品Price 3.30/Rice
最小起订Quantity:1 Rice 供货总Quantity: 10000 Rice
K-type thermocouple with ZR-KX-H-YVR-2*1.5 flame-retardant compensating cable; Terms of Use 1. Operating Temperature: Heat-resistant: two types, up to 200℃ and 260℃; General use: two types, up to 70℃ and 105℃. 2. Lowest environmental temperature: Fluoroplastic insulated and sheathed cables: Fixed installation - 60°C, non-fixed installation -20°C. Polyvinyl Chloride insulated and sheathed cables: Fixed installation -40°C, non-fixed installation -15°C. 3. Allowable Bend Radius: a) Compensation cables with copper tape shielding should not be less than 16 times the diameter of the cable; b) Compensation cables with other structures should not be less than 10 times the diameter of the cable. Model, Name (1) Compensation Wire Model Name KX-GS-VV PVC insulated and sheathed cables are typically used with precision-grade K-type thermocouples and compensating cables. KX-GS-VPV PVC insulated and sheathed copper wire braid shielding is generally used with precision K-type thermocouple compensation wires. KX-HS-FF High-temperature compensating wire for precision K-type thermocouples, suitable for heat-resistant insulation and sheath of fluoroplastic. KX-HS-FP1F Fluorinated plastic insulated and sheathed tin-plated copper wire braided shielding, high-temperature compensation wire for precision K-type thermocouples. KX-HS-FB PTFE insulated, glass fiber braided jacket, high-temperature compensation wire for precision K-type thermocouple. KX-HS-FBP1 PTFE tape wrapped insulated glass fiber braid, tin-plated copper wire braid shield, glass fiber braided outer sheath, high-temperature resistant precision K-type thermocouple compensation wire KX-HS-FP1V105 Fluoroplastic insulated tinned copper wire braid shielding, heat-resistant up to 105°C, with PVC sheath for high-temperature compensation wires used in precision K-type thermocouples. Note: The model representation for standard-grade compensation wire is to remove the letter "S" from the precision-grade compensation wire model (as applicable). Compensation Cable Model Name KX-GS-VV PVC insulated twisted PVC sheathed cables are commonly used with precision grade K type thermocouples and compensating cables. KX-GS-VPV PVC insulated twisted copper wire braid shielded with PVC sheath, generally used with precision grade K type thermocouple compensating cables. KX-GS-VPVP PVC insulated twisted copper wire braid offers both partial and full shielding. PVC sheath is commonly used with precision-grade K-type thermocouple compensating cables. KX-GS-VVP PVC insulated twisted copper wire braid with overall PVC sheath, generally used with precision grade K type thermocouple compensation cables. KX-HS-FF Fluoroplastic insulated twisted fluoroplastic sheathed precision K-type thermocouple with high-temperature compensation cable KX-HS-FP1F Fluoroplastic insulated twisted tinned copper wire braid shielded fluoroplastic sheath precision grade K thermocouple with high temperature compensation cable KX-HS-FP1FP1 Fluoroplastic insulated braided tin-coated copper wire, with both individual and overall shielding, for precision K-type thermocouple applications with high-temperature compensation cables. KX-HS-FFP1 Fluoroplastic insulated twisted pair tinned copper wire braid overall shielding fluoroplastic sheath precision K type thermocouple with high temperature compensation cable KX-HS-FV105 Fluoroplastic insulated thermally-resistant 105°C PVC sheathed cable, precision grade K type thermocouple with high temperature compensation wire KX-HS-FP1V105 Fluorinated plastic insulated, tin-plated copper wire braided, shielded, heat-resistant up to 105°C, PVC sheathed, precision grade K thermocouple, high-temperature compensation cable KX-HS-FP1V105P1 Fluoroplastic insulated, tin-plated copper wire braided, multi-screened, total shielding, heat-resistant up to 105°C, PVC sheathed, precision grade K thermocouple, high-temperature compensation cable KX-HS-FV105P1 Fluoroplastic insulated twisted pair tin-coated copper wire braided overall shielding, heat-resistant up to 105°C, PVC sheathed precision K-type thermocouple compensation cable Note: 1. Other models of compensation wires, such as KC, JX, SC, EX, NC, TX, etc., only need to modify the * item of the model, e.g., EX-G-VV, TX-H-FVP, etc. 2. When the conductor requires multiple strands of soft core, "R" should be added after the original model number, e.g., TX-G-VVPR. 3. We also offer polyethylene (Y) insulated and cross-linked polyethylene (YJ) insulated compensating cables, as required. 4. The shielding layer of the compensating cable can also be wrapped with metal strips, such as: composite aluminum strip (P3), composite copper strip (P2). 5. Flame-retardant compensating cables are required, and "ZR-" should be added before the original model number. 6. Armored compensating cables are required. Add "-22" after the original model number to indicate steel tape armor; add "-32" for steel wire armor. ZR-KX-H-YVR-2*1.5 flame-retardant compensation wire for K-type thermocouple.


Phone Consultation
QQ Service