Orion 083005MD 1.5m Oxygen Sensor Cable with 9-pin MiniDIN Connector
品牌: ORION Aolong
Packaging: Boxed
Operating Temperature: 0-100°C
Inspection Items: PH Water Analysis
单价: 9958.00/Piece
最小起订Quantity: 1 Piece
供货总Quantity: 1000 Piece
有效期至: 长期有效
最后更新: 2024-04-02 14:09
 
详细Info

Thermo Orion OxyGuard Dissolved Oxygen Electrode 083005MD:

083005MD Application: Laboratory and Field Measurement

Cable Length: 1.5 m

Matching Host Machine: Star Series

Sample low flow rate: 10 cm/second

Sample Temperature: 0 - 50℃

During electrolyte use: 180 days

Response Time: 90% achieved within 10 seconds, 95% within 15 seconds, and 99% within 1 minute.

Attachment Models: Film Sleeve - 080515, Electrolyte - 080514, Maintenance Kit - 080513

Oxygen Dissolved Measurement Basics

· During laboratory measurement of dissolved oxygen, the solution to be tested must be stirred at a constant speed; when measuring outdoors, the water body must have a certain flow rate to ensure the rate of dissolved oxygen passing through the electrode membrane.

· The solution must not generate an electromagnetic field that interferes with measurement signals during stirring or flow, to prevent instability in measurement data.

· Oxygen Saturation Electrode requires a certain polarization time before calibration and measurement

· When maintaining and repairing the dissolved oxygen electrode, the main power must first be turned off, then remove the electrode before proceeding with maintenance.

Order Number Description

080513 Dissolved Oxygen Maintenance Kit (1 bottle of electrolyte, 1 sheet of polishing paper, 2 membrane sleeves)

  083005MD, 083010MD, 083025MD, 083060MD, 086030MD, 083005A, 083010A,083025A, 083060A,083005D, 086020A, 083150A, 083010F, 081010F, 081030F

080515 - Protective Covering 1 Piece

  083005MD, 083010MD, 083025MD, 083060MD, 086030MD, 083005A, 083010A,083025A, 083060A, 083005D, 086020A, 083150A, 083010F, 081010F, 081030F

081003 - 3 Membrane Sleeves

  080510MD, 081010MD, 081010

Electrolyte

  083005MD, 083010MD, 083025MD, 083060MD, 086030MD, 083005A, 083010A,083025A, 083060A, 083005D, 086020A, 083150A, 083010F, 081010F, 081030F,080510MD, 081010MD, 081010