Orion 083005MD 1.5m Oxygen Sensor Cable with 9-Pin MiniDIN Connector_SupplyPro Co., Ltd._Guangzhou Borletech Technology Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Guangzhou Borletech Technology Co., Ltd.

Orion / Eutech / Precisa / Techcomp (formerly Shanghai Jingke) / LabTech

Soule Star Diamond Member
Consultation Hotline
18680226663

News Center Co., Ltd.
  • No News

Product Categories

Contact Information
  • Contact person:王小姐
  • Telephone:18680226663
  • Mobile:18680226663

Home > SupplyPro Co., Ltd. > Orion 083005MD 1.5m Oxygen Sensor Cable with 9-Pin MiniDIN Connector
Orion 083005MD 1.5m Oxygen Sensor Cable with 9-Pin MiniDIN Connector
品牌: ORION Aolong
Packaging: Boxed
Operating Temperature: 0-100°C
Inspection Items: PH Water Analysis
单价: 9958.00/Piece
最小起订Quantity: 1 Piece
供货总Quantity: 1000 Piece
有效期至: 长期有效
最后更新: 2024-04-02 09:50
 
详细Info

Thermo Orion OXY-DO dissolved oxygen electrode 083005MD:

Application of 083005MD: Laboratory and Field Measurement

Cable Length: 1.5 m

Matching Host Machine: Star Series

Sample low flow rate: 10 cm/sec

Sample Temperature: 0 - 50℃

Electrolyte usage: 180 days

Response Time: Achieve 90% within 10 seconds, 95% within 15 seconds, and 99% within 1 minute.

Attachment Model: Film Sleeve - 080515, Electrolyte - 080514, Maintenance Kit - 080513

Oxygen Saturation Measurement Basics

· When measuring dissolved oxygen in the lab, the solution being tested must be stirred at a constant speed; for outdoor measurements, the water body must have a certain flow rate to ensure the rate of dissolved oxygen passing through the electrode membrane.

· The solution must not generate an electromagnetic field that interferes with measurement signals during stirring or flow, to prevent instability in measurement data.

· Oxygen sensors require a certain polarization time before calibration and measurement.

· When maintaining the oxygen electrode, it is essential to first turn off the main power of the unit, then remove the electrode for maintenance.

Order Number Description

080513 Dissolved Oxygen Maintenance Kit (1 bottle of electrolyte, 1 sheet of polishing paper, 2 membrane sleeves)

  083005MD, 083010MD, 083025MD, 083060MD, 086030MD, 083005A, 083010A,083025A, 083060A,083005D, 086020A, 083150A, 083010F, 081010F, 081030F

080515 - Case 1 piece

  083005MD, 083010MD, 083025MD, 083060MD, 086030MD, 083005A, 083010A,083025A, 083060A, 083005D, 086020A, 083150A, 083010F, 081010F, 081030F

081003 - 3 Membrane Sleeves

  080510MD, 081010MD, 081010

Electrolyte Solution

  083005MD, 083010MD, 083025MD, 083060MD, 086030MD, 083005A, 083010A,083025A, 083060A, 083005D, 086020A, 083150A, 083010F, 081010F, 081030F,080510MD, 081010MD, 081010

询价单
 Click submit means you agree to《Service terms》《Privacy policy》

18680226663