详情描述

  1. Material Characteristics:
  • Particle size: For large particles (e.g., >100mm), a large opening sampler head and a powerful crusher must be selected.
  • Humidity: High humidity materials require anti-blocking design (e.g., increased inclined angle of chutes, additional vibration devices).
  1. Belt specifications:
  • Width: The sampling head must cover the full width of the belt (e.g., if the belt width is 1200mm, the sampling head width ≥ 1300mm).
  • Pitch angle: Generally ≤15°, special design required for anti-sample slip structure in high pitch angle scenarios.
  1. Detection Accuracy:
  • High precision requirements (e.g., calorific value error ≤ ±1%) necessitate increasing the number of samples (recommended ≥ 30 per batch) or configuring multi-stage sub-sampling.
  1. Compliance:
  • Export projects must comply with ISO, ASTM standards; domestic projects must meet GB/T 19494, GB 50074, and other regulations.