Publish Time:2023-06-02        View Count:9         Return to List

Jiangmen Building Safety Inspection and Appraisal Company

Our company offers a toll-free consultation line, where trained professionals are available to listen to your needs and provide you with suitable technical service units, ensuring efficient service. Our services cover: residential quality and safety inspections, industrial factory structure appraisals, school and kindergarten seismic evaluations, building condition assessments, main structure quality inspections, and assessment of old neighborhood renovations.

Home Inspection Content and Procedures:

1. Residential Structure Status Survey

The company conducted a review and survey of the existing floor layout, component arrangement, and story heights of the building structure. This work focuses on ascertaining the current state of the building's structure, verifying its consistency with the original design, and conducting surveying and mapping if discrepancies are found.

Column grid dimensions

② Ceiling Height

③ Verify the layout of the wall columns and main beams.

2. Current Condition Survey of Residential Properties

The primary inspection involves assessing the severity of damage to the exterior of various building components, such as beams, slabs, columns, and filled walls, including surface peeling, cracking (or spalling), color change, deflection, and melting.

3. Detection of the extent of concrete strength impact on buildings

Due to the damage to the concrete surface from overheating and factors such as accuracy, the core drilling method is used for concrete strength testing.

4. Component cross-sectional dimensions and reinforcement configuration inspection

In accordance with GB50204-2002 standards and relevant design drawings, the main concrete structural components of the building were sampled for cross-sectional dimension and reinforcement configuration inspection and verification. The reinforcement configuration inspection primarily includes the quantity of main reinforcement bars, spacing of stirrup configuration, and thickness of the protective layer, with selected samples undergoing reinforcement diameter verification.

5. House Tilting and Uneven Settlement Detection

To ensure the structural integrity and foundation conditions of the building, an theodolite was used to detect the tilt tendency of the building. Inspections were conducted on the building's outer corners and other critical areas. Verticality checks were also performed on some internal components. Overall, observations were made on points at the same relative elevation for assessing uneven settlement. A comprehensive analysis of the building's overall tilt and uneven settlement was conducted based on these inspections. A survey of the upper structure's damage conditions was conducted to observe any significant deformation or cracking in the main structure, reflecting potential uneven settlement trends in the lower foundation.