The Gel Ball Cleaning Device utilizes fluid mechanics by introducing rubber sponge balls during operation. Due to the balls being slightly larger in diameter than the heat exchanger pipes, they effectively scrub the pipe walls and remove accumulated impurities. Equipped with an intelligent control system, the device continuously sends and receives the gel balls to achieve automatic online cleaning without shutting down the equipment.
When the collection rate of the ball cleaner does not meet the predetermined standards, it may be due to the following reasons:
1. The catching net failed to be cleaned in a timely manner, resulting in dirt blockage and a decrease in its operational efficiency.
2. Insufficient water flow in the cooling cycle system results in inadequate kinetic energy, preventing the gel balls from reaching the collection chamber.
3. The rubber balls were not properly de-aerated according to technical specifications before being added to the system; instead, they were soaked in water.
4. Mismatched selection of rubber ball pumps. The rubber ball pump can affect the recovery efficiency of rubber balls in different seasons, so when selecting, it is important to choose a pump with low power consumption, high ball delivery, and low cutting rate.
Issue 5: The ball receiver's structure is not properly designed, resulting in the "ball rolling away" phenomenon.
Above are the common causes of low ball collection rate in the胶球 cleaning device. To ensure the use of the circulating water system is not affected, pre-check and maintenance should be carried out before the equipment is operated, extending the service life of the equipment.