High-Temperature and Low-Temperature Alternating Humidity and Heat Test Chamber | High-Temperature and Low-Temperature Humidity Chamber_SupplyPro Co., Ltd._Suzhou Morning Sun Test Equipment Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》

Suzhou Morning Sun Test Equipment Co., Ltd.

Professional manufacturer of testing equipment

13812650780
0512-66361656
 

Product Categories

Contact Information
  • Contact person:张先生
  • Telephone:0512-66361656
  • Mobile:13812650780
  • Address:Yao Feng East Road, Mudu Town, Suzhou City
Home > SupplyPro Co., Ltd. > High-Temperature and Low-Temperature Alternating Humidity and Heat Test Chamber | High-Temperature and Low-Temperature Humidity Chamber
High-Temperature and Low-Temperature Alternating Humidity and Heat Test Chamber | High-Temperature and Low-Temperature Humidity Chamber
品牌: Morningsun Testing Equipment
Company: Suzhou Morgenlight Testing Equipment Co., Ltd.
Brand: Dawn Test Equipment
Region: Suzhou
单价: 999.00/Tai
最小起订Quantity: 1 Tai
供货总Quantity: 999 Tai
有效期至: 长期有效
最后更新: 2023-09-08 13:48
 
详细Info

1. The high and low temperature alternating humidity and heat test chamber features an original imported microcomputer large LCD (320*240 dots) touch screen control system with both Chinese and English display.
2. High and low temperature alternating humidity test chamber with high capacity, programmable for 120 patterns; 1200 steps; 999*999 cycles, with arbitrary connection between programs.Perform, an infinite loop of repetitive testing, with each time period set to max 99 Hrs 59 Mins
3. Control Method: Smart PID with SSR/SCR bi-directional synchronous output, featuring computerized slope control logic, equipped with RS-232C and 485 communication interfaces, allowing for computer-based operation, editing, recording, and two dynamic contacts (TIMER SIGNAL RELAY), easy to use.
4. Programmable LCD display screen Back Light activation time to extend the Back Light's lifespan.
5. Features include program correction, clearing, scheduled startup, and power failure memory.
All components for heating, cooling, humidifying, and dehumidifying are fully controlled by a microcomputer, with each system entirely independent.
Utilizing STN TYPE wide-angle LCD English display control system
Programmed capacity max is 120 sets: 100 segments: 999 cycles
Programmable for flexible chaining (l)Ink) and (Separate)

Model

GDJS -100

GDJS -150

GDJS -225

GDJS -408

GDJS -800

GDJS -1000

Content Volume (L)

100

150

225

408

800

1000

Internal Dimensions (mm) W×H×D

400×500×500

500×600×500

500×750×600

600×850 ×800

1000×1000×850

1000×1000×1000

External Dimensions (mm) W×H×D

850×1400×1050

950×1500×1050

950×1765×1150

1050×1850×1350

1450×1900×1350

1450×1900×1550

Weight (Kg)

200

250

300

400

600

700

Performance

Thermohygrometric Control Method

Balanced Temperature and Humidity Control (BTHC) PID Intelligent Regulation

Temperature Range

0°C, -20°C, -40°C, -60°C, -70°C to 150°C (optional)-80 ℃ ~150 ℃、-100 ℃ ~150 ℃

Humidity Range

20%-98%R.H

Uniformity of temperature

±1.5℃

Temperature fluctuation

±0.5℃

Uniform humidity distribution

±3%R.H

Humidity Fluctuation

±1%R.H

Rising temperature rate

≥ 2.5°C/min

Cooling rate

1°C/min

Material

Inner material

SUS304 Bright Stainless Steel Sheet

Outer Shell Material

SUS304 brushed stainless steel sheet or rust-resistant treated cold-rolled steel sheet (powder coated)

Insulating Material

Ultra-fine glass wool + Polyurethane foam

Regulator

Cooling Method

Mechanical binary refrigeration method

Cooling unit

Fully enclosed compressor (Thermocold from France or GEA from Germany)

Refrigerant

R404A (Environmentally Friendly)

Condensation Method

Air-cooled or Water-cooled

Heater

Nickel-chromium alloy stainless steel tube heater

Humidifier

Stainless Steel Humidifier Drum

Blower

Centrifugal Fan

Airflow method

Wide-Beam Forced Airflow Circulation (top entry, bottom exit)

Controller

Operation Interface

LCD Touch Screen Display, Switchable between Chinese and English

Operation Method

Continuous Operation, Programmed Operation

Program memory capacity

120 programmable, each program max 999 (segments)

Set target range

Temperature: -100℃ to +300℃; Humidity: 99.9% R.H.

Resolution

Temperature: 0.1℃; Humidity: 0.1% R.H.

Input

PT100 Platinum Resistance Element

Control Method

PID Control

Communication Function

RS-232 Interface

Printing Function

Nippon Daisan 6-Point Logger (optional accessory)

Additional Features

Upper and lower limit alarms, self-diagnosis, alarm display (fault cause), timing device (auto-start, auto-shutdown)

Water Supply

Supply Method

Recirculating Water Supply

Water Storage Tank

Built-in carry handle (30kg capacity)

Water Quality

Resistance > 500 Ω·m

Standard Configuration

Observation window (double-layered insulating tempered glass) 1 pc; Test hole 60mm (located on the left) 1 pc; Sample holder 2 levels; Inside box lighting (fluorescent light) 1 pc; Water tank 1 pc;

Safety Device

Leakage protector for power supply, dry burn prevention device, water system protection unit, extreme high and low temperature protection, temperature deviation alarm, overpressure, overload, water shortage, and equal deficiency protection

AboveHigh and low temperature alternating humidity test chamberDimensions can be customized according to the customer's specific requirements.


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

13812650780