Thoroughly check the layout diagram before installation to identify the installation positions of each wall panel component. During the wall panel hoisting process, two workers assist in controlling the rotation of the panel in the air. The lifting height should not exceed 50cm, and the hoisting rope should be slowly raised and lowered to prevent磕碰 the panels. After the wall panel is in place, check the vertical and horizontal alignment; adjust the ends with zinc-plated angle steel shims if the deviation exceeds the design, then secure it using bolts and zinc-plated angle steel heads.