Qingdao 20-ton gas boiler_SupplyPro Co., Ltd._Shandong Zhongjie Special Equipment Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Shandong Zhongjie Special Equipment Co., Ltd.

Zhongjie Special Tank Co. specializes in the installation services of LNG tan...

Consultation Hotline
15253010956  18769007684

News Center Co., Ltd.

Product Categories
  • No Category

Contact Information
  • Contact person:于秋波
  • Telephone:15253010956
  • 邮件:931369632@qq.com
  • Mobile:18769007684

Home > SupplyPro Co., Ltd. > Qingdao 20-ton gas boiler
Qingdao 20-ton gas boiler
品牌: Zhong Jie
Brand: He锅
Condition (new/used): Brand New
Location of equipment: Heze
单价: 10000.00/Tai
最小起订Quantity: 1 Tai
供货总Quantity: 9999 Tai
有效期至: 长期有效
最后更新: 2025-06-09 15:06
 
详细Info

Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) was established in 2001, located at No. 2218 Jinnan Road, Development Zone, Heze City. With a registered capital of 50 million yuan and total assets of 500 million yuan, the company has 7 business centers: boilers, deep-freezing containers, pressure vessels, central air conditioning, engineering installation, international trade, and Internet of Things. It has three factory sites on Jinnan Road, East Changjiang Road, and Bohai Road, covering a total of 200,000 square meters. The main workshop spans 83,000 square meters. It currently employs 710 people, including 247 engineers and technicians, and 82 intermediate-level technicians. In December 2016, it was recognized as a "High-tech Enterprise" by the Science and Technology Department. In June 2021, it was identified as a "Specialized and New Enterprise in Shandong Province" by the Ministry of Industry and Information Technology. In June 2022, it was recognized as a "Gazelle Enterprise in Shandong Province" and in August 2022, as a "Specialized and New Small Giant Enterprise" by the Ministry of Industry and Information Technology.
For the maintenance of industrial gas boilers, here are some common methods and precautions: - Clean the burner: Regularly clean the interior of the burner and nozzles to ensure normal combustion of the gas and prevent carbon accumulation and blockages. - Check the gas supply system: Regularly inspect the gas supply system, including gas pipelines, valves, and pressure regulators, to ensure normal gas supply without leaks or blockages. - Clean the flue and heat exchanger: Regularly clean the flue and heat exchanger to remove ash and dirt, maintaining heat exchange efficiency and preventing overheating and energy loss. - Check water level and pressure: Regularly inspect the boiler's water level and pressure to ensure safe operation within the appropriate range. Top up water and adjust pressure to avoid issues caused by low or high water levels. - Check safety devices: Regularly inspect the boiler's safety devices, including safety valves, pressure switches, and water level controllers, to ensure they are functioning properly and ensure the safe operation of the boiler. - Check the control system: Regularly inspect the boiler's control system, including automatic controllers, sensors, and instruments, to ensure accuracy and reliability, and to promptly detect and repair faults. - Scheduled maintenance: Regular maintenance includes lubricating components, replacing worn parts, and checking electrical connections to extend the boiler's lifespan and stability. - Keep records: Document the boiler's operating parameters, maintenance records, and fault situations to help promptly identify and analyze operational conditions. - Train operators: Ensure operators are sufficiently
青岛20吨燃气锅炉
To optimize and improve the planning of gas-fired boilers, consider the following aspects: 1. Energy Audit and Assessment: Conduct a comprehensive energy audit and assessment to understand the energy consumption of the gas boiler system and identify potential energy-saving opportunities. Through data analysis and energy measurement, determine the main sources of energy consumption and bottlenecks, providing a basis for subsequent optimization. 2. Combustion System Optimization: Optimize the combustion system of the gas boiler, including adjustments and cleaning of burners, control of the ratio of gas to air, and maintenance of the combustion chamber. Ensure high combustion efficiency and high gas utilization, reducing energy waste. 3. Heat Recovery Utilization: Consider installing heat recovery devices such as waste heat recovery units or flue gas heat exchangers. These devices can utilize the excess heat from the flue gas emitted by the gas boiler to heat water or other equipment requiring heat, improving energy efficiency. 4. Pipe Insulation and Leak Inspection: Ensure that the insulation performance of gas and hot water pipes is good, reducing energy loss. Regularly inspect for pipe leaks and repair them promptly to avoid energy waste and safety hazards. 5. Control System Upgrade: Consider upgrading the control system of the gas boiler to adopt automated control technology. Through precise control and adjustment, achieve optimal operation of the gas boiler.
青岛20吨燃气锅炉
Before starting the heating gas hot water boiler, the following proper procedures must be followed: - Check the gas supply system: Ensure the gas supply system is operating normally, inspect gas pipelines, valves, and pressure regulators, and ensure there are no leaks or blockages in the gas supply. - Check the water system: Inspect the water circulation system of the heating system, including pumps, valves, and pipes, to ensure the waterway is clear with no leaks or blockages. - Check the electrical system: Inspect the electrical system of the boiler, including power connections, controllers, and sensors, to ensure electrical equipment is functioning properly. - Check the safety devices: Inspect the boiler's safety devices, including safety valves, pressure switches, and water level controllers, to ensure they are working correctly and ensure the safe operation of the boiler. - Prepare for ignition: According to the boiler's operating instructions, prepare the tools and equipment required for ignition, including igniters and ignition electricity. - Open the gas valve: Slowly open the gas valve to ensure a steady gas supply and avoid gas surges. - Ignition start-up: Follow the boiler's operating instructions to initiate the ignition start-up. Perform the appropriate operations according to the boiler model and control system to ensure smooth ignition. - Monitor operating status: After startup, closely monitor the boiler's operating status, including combustion, water level, and pressure, to ensure normal operation without any abnormalities. - Adjust parameters: Adjust the boiler's parameters according to actual needs, including temperature, pressure, and water level, to meet the requirements of the heating system. - Regular maintenance: After startup, perform regular maintenance, including cleaning the burner, checking water level and pressure, and replacing worn parts, to ensure normal and safe operation of the boiler. - It is recommended to refer to the boiler's operation manual and the manufacturer's guidance before starting the heating gas hot water boiler to ensure correct and safe operation. If necessary, a person may be required for operation and maintenance.
青岛20吨燃气锅炉
1-ton gas-fired steam boiler's gas consumption over a year is influenced by various factors, including the efficiency of the boiler, load conditions, and operating hours. Generally, it can be estimated using the following formula: Gas Consumption (m) = Boiler Efficiency × Boiler Rated Thermal Power × Operating Hours. Here, boiler efficiency refers to the boiler's energy utilization efficiency, typically expressed as a percentage; boiler rated thermal power is the boiler's rated thermal output, usually in kilowatts (kW); operating hours are the time the boiler is in operation, commonly measured in hours. It's important to note that the boiler's efficiency and rated thermal power can be determined based on the specific model and parameters of the boiler, while operating hours need to be estimated based on actual usage. Therefore, to accurately calculate the 1-ton gas-fired steam boiler's annual gas consumption, it is recommended to refer to the technical specifications and operating records of the boiler, or consult the boiler manufacturer or engineer.
Our company attaches great importance to technological innovation and R&D design. We have one municipal-level enterprise technology center in Heze City, equipped with non-destructive testing, physical and chemical testing, welding testing, hydrostatic testing, and other testing facilities. We have over 600 types of equipment, including CNC machine tools, X-ray flaw detectors, digital ultrasonic flaw detectors, mechanical property testing machines, chemical analyzers, spectrometers, tensile testing machines, plasma welding machines, and more. The key products and technologies we have developed, such as temperature and pressure vessel welding, biomass boiler emission reduction, and waste heat utilization, have successively been selected for multiple Shandong Provincial Department of Industry and Information Technology science and technology innovation projects, Shandong Provincial key projects, and Heze City innovation and excellence projects. We have accumulated a total of 27 authorized utility models, 16 authorized inventions, participated in drafting 2 standards, 2 industry standards, and registered 15 trademarks. The technical team of our company, in collaboration with Professor Yajiang Li from Shandong University, has developed deep cryogenic container processing technology using the international plasma arc + wire filling argon arc welding (PAW-GTAW) technology. After provincial-level scientific and technological achievement evaluation, the technology level has reached an international standard in the field of deep cryogenic container manufacturing.
Choose ZJETT Customization, let's create brilliance together!

询价单
 Click submit means you agree to《Service terms》《Privacy policy》

18769007684