Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) was established in 2001, located at No. 2218 Jinnan Road, Economic and Technological Development Zone, Heze City. With a registered capital of 50 million yuan and total assets of 500 million yuan, the company has 7 business centers: boilers, deep-freezing containers, pressure vessels, central air conditioning, engineering installation, international trade, and Internet of Things. It has three factory sites on Jinnan Road, East Changjiang Road, and Bohai Road, covering a total area of 200,000 square meters, with the main workshop spanning 83,000 square meters. The company currently employs 710 people, including 247 engineers and technicians and 82 intermediate-level technicians. In December 2016, it was recognized as a "High-tech Enterprise" by the Science and Technology Department. In June 2021, it was identified as a "Specialized and New Enterprise in Shandong Province" by the Department of Industry and Information Technology. In June 2022, it was recognized as a "Gazelle Enterprise in Shandong Province" and in August 2022, as a "Specialized and New Small Giant Enterprise" by the Ministry of Industry and Information Technology.
When selecting a low-temperature liquefied natural gas (LNG) storage tank, the following factors should be considered:
Storage Tank Types: Common LNG storage tank types include vertical fixed-roof tanks, spherical tanks, and horizontal tanks. Choose the appropriate tank type based on specific application requirements and site conditions.
Tank Capacity: The capacity of the tank is determined based on the storage requirements of LNG and the estimated usage volume. The tank capacity should meet the expected storage period and supply demands.
Material Selection: LNG tanks typically use low-temperature steel or nickel alloy materials to ensure corrosion resistance and strength in low-temperature environments. Select appropriate materials based on the design pressure and temperature requirements of the tank.
Safety Performance: LNG tanks should possess excellent safety features, including seismic resistance, fire resistance, and leakage control capabilities. The tanks must comply with relevant safety standards and regulations, such as API 620, EN 1473, and others.
Maintenance and Repair: Consider the storage tank's maintenance and repair requirements, including internal cleaning, coating protection, and anti-corrosion measures. The tank's design should facilitate maintenance and repair operations to ensure long-term reliable operation.
Environmental Impact: When selecting LNG tanks, the impact on the surrounding environment must be considered. The layout and design of the tanks should comply with environmental protection requirements, minimizing noise, vibration, and gas emissions to reduce environmental impact.
Cost-Effectiveness: Consider the investment, operational, and lifecycle costs of the tank to choose one with a favorable cost-performance ratio.
需要注意的是,选型LNG储罐时应遵循相关的和地区的法规、标准和规范。此外,咨询的工程师或储罐制造商,以获取更详细和准确的选型建议。
The use of low-temperature liquid storage tanks requires attention to the following:
Safe Operation: Operators must undergo training to understand the operational procedures and safety precautions for the tanks. Adhere to the correct operational steps to ensure safe operation.
Protective Gear: Operators must wear appropriate protective gear, such as thermal suits, gloves, etc., to safeguard themselves from harm caused by low-temperature liquids.
Leak Protection: Regularly inspect the tank and associated piping for seal integrity to prevent leakage of low-temperature liquids. Keep the area around the tank clean to avoid debris obstructing leak detection and handling.
Fire Protection: Low-temperature liquids are highly flammable and fire prevention measures must be taken. Keep the storage tank area free from ignition sources, prohibit smoking and open flames. Equip with appropriate fire extinguishing equipment to address fire risks.
Pressure Control: Regularly inspect and maintain the pressure control system of the storage tank to ensure that the pressure inside the tank is within the safe range. Safety valves and pressure sensors, among other equipment, should operate normally, and abnormal pressure situations should be detected and addressed promptly.
Insulation Protection: Low-temperature liquid storage tanks should be equipped with an effective insulation layer to reduce heat transfer and evaporation of the liquid. The selection and installation of the insulation layer should comply with relevant standards and requirements.
Regular Inspections and Maintenance: Conduct regular inspections of the tank's exterior and interior, including checking for leaks, corrosion, wear, or other damage. Pay special attention to the tank's interfaces, valves, and pipelines, ensuring they are functioning properly.
Emergency Preparedness: Develop an emergency response plan, including measures for leaks, fires, and other unforeseen incidents. Operators should be familiar with the emergency response plan and be equipped with appropriate emergency equipment and firefighting gear.
Zhongjie Special Equipment is a company specializing in the production of low-temperature liquid storage tanks. They offer a range of specifications and capacities, including liquid nitrogen tanks, liquid oxygen tanks, liquid argon tanks, and more.
The Zhongjie liquid storage tank is constructed with high-quality materials and advanced manufacturing techniques, ensuring the tank's strength and sealing integrity. The internal design features special insulation materials and structure, effectively reducing evaporation losses of the liquid.
The Zhongjie special-purpose low-temperature liquid storage tank features the following characteristics:
High safety: Tanks are made of materials with excellent pressure resistance and sealing performance, capable of safely storing low-temperature liquids.
Low evaporation loss: Insulation materials and structural design used inside the tank effectively reduce liquid evaporation loss, enhancing the tank's economic efficiency.
A variety of specifications and capacities available: Zhongjie provides a range of low-temperature liquid storage tanks in different specifications and capacities to meet diverse customer needs.
Customized Design: JieJet can offer tailored design and manufacturing services according to specific customer requirements, to accommodate various application scenarios.
Quantitative Manufacturing Process: Zhongjie is equipped with advanced manufacturing equipment and a skilled technical team, ensuring the quality and performance of the storage tanks.
In summary, Zhongjie Special Equipment's low-temperature liquid storage tanks offer high safety, low evaporation loss, and a wide range of specifications, catering to storage and transportation needs for low-temperature liquids.
The safety distance for liquid oxygen storage tanks refers to the distance that must be maintained around the tank to ensure the safety of personnel and equipment. The specific requirements for safety distances may vary depending on different regions and application sites. Here are some common principles for safety distances:
Buildings and Equipment: Liquid oxygen storage tanks should be kept at a certain distance from buildings, equipment, and other storage tanks to prevent the spread of fires, explosions, and leaks. The specific safety distance requirements should be assessed and determined according to local regulations and standards.
Fire Sources and Heat Sources: Liquid oxygen is highly oxidizing and can easily cause fires and explosions. Therefore, liquid oxygen storage tanks should be kept at a sufficient distance from fire sources, heat sources, and flammable materials to prevent fires and explosions.
Ventilation and Exhaust: Good ventilation and exhaust should be maintained around liquid oxygen storage tanks to prevent the accumulation of evaporated liquid oxygen and the formation of explosive mixtures. The design and operation of the ventilation and exhaust system should comply with relevant safety standards and specifications.
Personnel and Traffic: Personnel and traffic around liquid oxygen storage tanks should be restricted and controlled to ensure personnel safety and the normal operation of the tank. Warning signs, safety fences, and restricted areas should be established to prevent unauthorized personnel from entering the tank area.
It is important to note that the safety distance for liquid oxygen storage tanks should be assessed and determined based on the specific application site and safety requirements. When designing, installing, and operating liquid oxygen storage tanks, relevant regulations, standards, and safety guidelines should be followed to ensure the safety and reliability of the tank.
Shandong Zhongjie Special Equipment, welcome customers to our factory for business discussions.
Huangnan 5 cubic meter liquid argon storage tank - Trusted







