Sui Ning Liquid Nitrogen Tank, In Stock Supply_SupplyPro Co., Ltd._Shandong Zhongjie Special Equipment Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Shandong Zhongjie Special Equipment Co., Ltd.

Zhongjie Special Tank Co. specializes in the installation services of LNG tan...

Consultation Hotline
15253010956  18769007684

News Center Co., Ltd.

Product Categories
  • No Category

Contact Information
  • Contact person:于秋波
  • Telephone:15253010956
  • 邮件:931369632@qq.com
  • Mobile:18769007684

Home > SupplyPro Co., Ltd. > Sui Ning Liquid Nitrogen Tank, In Stock Supply
Sui Ning Liquid Nitrogen Tank, In Stock Supply
品牌: Zhongjie
Structural form: Vertical
Pressure: 0.8 or 1.6 MPa
Type: Oxygen, Nitrogen, Argon Storage Vessel
单价: 10000.00/Tai
最小起订Quantity: 1 Tai
供货总Quantity: 9999 Tai
有效期至: 长期有效
最后更新: 2025-06-14 08:48
 
详细Info

Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) was established in 2001, located at No. 2218 Jinnan Road, Economic and Technological Development Zone, Heze City. With a registered capital of 50 million yuan and total assets of 500 million yuan, the company has 7 business centers: boilers, deep-freezing containers, pressure vessels, central air conditioning, engineering installation, international trade, and Internet of Things. It has three factory areas on Jinnan Road, East Changjiang Road, and Bohai Road, covering a total of 200,000 square meters, with the main workshop area at 83,000 square meters. It currently employs 710 people, including 247 engineering and technical personnel and 82 intermediate-level technicians. In December 2016, it was recognized as a "High-tech Enterprise" by the Science and Technology Department. In June 2021, it was identified as a "Specialized and New Enterprise in Shandong Province" by the Ministry of Industry and Information Technology. In June 2022, it was recognized as a "Gazelle Enterprise in Shandong Province" and in August 2022, it was identified as a "Specialized and New Small Giant Enterprise" by the Ministry of Industry and Information Technology.
The reason for occasional venting of liquid oxygen tanks is primarily to maintain the safe pressure range within the tank and prevent excessive pressure buildup. Here are several situations where liquid oxygen tanks may be vented occasionally:
Pressure Control: During operation, the pressure inside a liquid oxygen storage tank can change due to evaporation of the liquid oxygen and temperature fluctuations. To maintain a safe pressure range within the tank, regular venting is required to control the tank pressure within a secure limit.
Prevent Excessive Pressure Build-up: During oxygen filling or usage, external factors or operational errors may cause the pressure inside the liquid oxygen tank to exceed the safe limit. To prevent excessive pressure build-up, timely venting is required to alleviate the pressure within the tank.
Prevent Gas Accumulation: Liquid oxygen tanks may contain some gas impurities, such as air and water vapor. These gases can condense into liquids or solids at the low temperatures of liquid oxygen, blocking pipes or affecting the normal operation of the tank. Regularly releasing gas can expel these impurities, maintaining the tank's cleanliness and unobstructed flow.
Note that the venting operation of liquid oxygen should be conducted by trained personnel and strictly adhere to the relevant operational procedures and safety measures. During the venting process, precautions should be taken to prevent leaks of liquid oxygen and contact with it, ensuring the safety and reliability of the operation.
遂宁液氮储罐
Material control for low-temperature liquid storage tanks is a critical aspect for ensuring the tank's safety and reliability. Here are some common material control measures:
Material Selection: Choose materials suitable for low-temperature environments, such as low-temperature alloy steel, stainless steel, etc. These materials exhibit excellent low-temperature resistance and crack resistance, maintaining strength and toughness under低温 conditions.
Material Quality Control: Ensure the selected materials meet relevant standards and specifications. Conduct chemical composition analysis, mechanical property tests, and impact tests on the materials to ensure their performance meets design requirements.
Welding Material Selection: Choose welding materials suitable for low-temperature environments, such as low-temperature welding rods or welding wires. The welding materials should match the storage tank material, featuring good welding properties and crack resistance.
Welding Process Control: Monitor welding process parameters such as current, voltage, and speed to ensure the quality and reliability of the weld joints. Methods with low heat input, such as pulse welding and laser welding, can reduce the temperature gradient and residual stress in the heat-affected zone.
Corrosion Prevention Measures: Apply corrosion-resistant treatments to both the internal and external metal surfaces of the storage tank to extend its service life. Options include corrosion-resistant coatings and paints to protect the tank's metal structure from corrosion.
Material Performance Monitoring: Conduct regular performance monitoring of the tank materials, such as mechanical property tests,
遂宁液氮储罐
To safely utilize liquid oxygen tanks, attention should be given to the following aspects:
Training: Operators of liquid oxygen tanks must undergo training to understand the properties of liquid oxygen, safety operating procedures, and emergency response measures. Only trained personnel are authorized to operate liquid oxygen tanks.
Safety Operating Procedures: Establish and adhere to the safety operating procedures for liquid oxygen storage tanks, including proper operational procedures, protective measures, and emergency response plans. Ensure operators follow the procedures to minimize accident risks.
Equipment Inspection and Maintenance: Regularly inspect the condition of liquid oxygen storage tanks and related equipment, including valves, pipelines, pressure gauges, etc. Ensure the equipment is intact and promptly repair or replace any damaged parts.
Leakage Control: Equipped with leak detection and alarm systems to promptly identify and control leaks in liquid oxygen storage tanks. Upon detection of a leak, immediate action should be taken to contain the source of the leak and proceed with repairs.
Fire Prevention Measures: Liquid oxygen has a high oxygen content and is prone to cause fires. Measures such as installing fire barriers around liquid oxygen storage tanks and using fire-resistant coatings are taken to prevent the occurrence and spread of fires.
Electrostatic Protection: The accumulation of static electricity in liquid oxygen tanks may cause sparks, increasing the risk of fire. Measures such as using electrostatic conductive materials and anti-static equipment should be taken to reduce the buildup and discharge of static electricity.
Ventilation Requirements: Ensure adequate ventilation within the enclosed space of the liquid oxygen storage tank to expel gases produced by the evaporation of liquid oxygen. Avoid excessive oxygen concentration and minimize
遂宁液氮储罐
Low-temperature industrial gas filling stations are facilities used to fill liquid low-temperature industrial gases (such as liquid oxygen, liquid nitrogen, liquid argon, etc.) into gas storage tanks. Here are some basic facts about low-temperature industrial gas filling stations:
Tank Type: Low-temperature industrial gas tanks commonly use double-walled vacuum insulated tanks, with the inner wall for storing liquid gas and the outer wall for insulation to reduce heat transfer and evaporation loss of the liquid gas.
Filling Equipment: Low-temperature industrial gas storage tank filling stations include liquid-gas filling pumps, filling pipelines, flowmeters, pressure sensors, and other equipment. The liquid-gas filling pumps are used to extract liquid gas from storage tanks or gas storage tanks and fill it into the target storage tank.
Filling Process: The operational steps at the filling station typically include: Preparations (check equipment, prepare filling medium), Equipment Connection (connect filling pumps, pipelines, etc.), Equipment Activation (start the filling pump, adjust flow and pressure), Filling Operation (filling liquid gas into the target storage tank), Monitoring and Control (monitor pressure, flow, and other parameters during filling to ensure safety and quality), and Operation Completion (shutdown equipment, clean work area).
Safety Measures: Strict adherence to relevant safety operation procedures and standards is required during the operation of low-temperature industrial gas filling stations. Operators should receive training to understand the properties and safety considerations of liquefied gases. Additionally, filling stations should be equipped with safety equipment such as pressure sensors and safety valves to ensure safety during the filling process.
Quality Control: During the filling process, quality control is required at the filling station, including monitoring the flow, pressure, and temperature of the filling medium to ensure the accuracy and quality of the filling.
It is important to note that the operation of low-temperature industrial gas storage tank filling stations must be conducted by trained personnel and strictly adhere to the relevant operational procedures and safety measures. Additionally, the design and manufacture of the filling stations should comply with applicable standards and regulations to ensure the safety and reliability of the equipment.
ZJ Special Equipment adheres to the great vision of "realizing employee dreams, creating customer value, and striving for the prosperity and strength of our motherland," wholeheartedly committed to the development of green energy equipment. We dedicate our high-value products and services to society!

询价单
 Click submit means you agree to《Service terms》《Privacy policy》

18769007684