Five Steps of Hydration for Mixers_News Center Co., Ltd._Five Steps of Hydration for Mixers,Shandong Baogran Chemical Equipment Co., Ltd._Shandong Baogran Chemical Equipment Co., Ltd._Zhongshang 114 Industry Resources Network
Shandong Baogran Chemical Equipment Co., Ltd.

Main Products: Mixers, Side-Entry Mixers, Top-Entry Mixers, Stainless Steel Mixers, Vertical Mixers, Paddle Mixers, Frame Mixers, Spiral Mixers

Consultation Hotline
15589328886  15589328886
 

Company Information

Location:Shandong/Zibo

会员级别:采商通3

身份认证:   

我的勋章:  通过中商114认证 [诚信档案]

Business Card

  • 公司名称Shandong Baogran Chemical Equipment Co., Ltd.
  • 联 系 人张经理 (先生)
  • 公司电话15589328886
  • 手机号码15589328886
  • Company AddressShandong Province, Zibo City, Fujia Industrial Park, Zhangdian District
home > News Center Co., Ltd. > Five Steps of Hydration for Mixers
News Center Co., Ltd.
Five Steps of Hydration for Mixers
Publish Time:2022-10-16        View Count:32        Return to List

The hydrogenation step of the blender is quite intricate; understanding the process is crucial when in use.

1. Check that all valves on the mixer are tightly closed, and direct the exhaust hose to an open, well-ventilated area.

2. Install the hydrogen gas pressure-reducing valve and nitrogen pressure valve, and after installation, check for leaks using soap and water.

3. Extract air above the liquid surface through the exhaust port using a vacuum.

4. Open the mixer's air intake valve, then open the nitrogen pressure-reducing valve, fill with nitrogen, and after achieving the internal kettle pressure, close the nitrogen and pressure-reducing valves, and shut the air intake valve. Maintain this for about two minutes, observing the pressure gauge to see if the pressure drops. Additionally, bend down and listen for any leaks from the valves and kettle cover. If no leaks are detected, gradually open the exhaust valve to release the internal pressure to 0.01 Mpa, then close the exhaust valve. Repeat this step once more.

5. Open the intake valve, activate the hydrogen pressure-reducing valve, fill hydrogen to the required pressure, close the intake valve, close the hydrogen pressure-reducing valve, and then adjust the stirrer's other parameters to the desired state for the reaction.

The hydrogenation step of the mixer is simple, highly versatile, and more convenient for everyone's choice. Welcome both new and old customers to select our products.



 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
15589328886