1. Open each independent loop's thermal oil conduit for heat transferOil FurnaceThermal oil furnaceHighPort exhaust valve.
2. Initiated the supply pump for the thermal oil heater, filled thermal oil into the circulating oil pipeline. There was thermal oil overflow at the gas valve, then closed the exhaust valve.
When the thermal oil level in the expander exceeds the low oil level marker, discontinue the addition of thermal oil.
4. Start the circulating oil pump for the heat transfer oil heater. After the heat transfer oil flows in the circulating pipes for 1 hour, open the exhaust valve until oil overflows, then close the exhaust valve.
5. Check the liquid level of the heat transfer oil in the expander; if it's below the low oil marker, start the heat transfer oil supply pump to add more heat transfer oil until the liquid level is above the low oil marker on the heat transfer oil furnace.