Tianjin Cable Corporation's Rubber and Plastic Cable Factory

Coal mine rubber sheathed cables, coal mine optical cables, coal mine control...

Consultation Hotline
13613264222

联系方式
  • Contact person:李文通
  • Telephone:13613264222
  • Mobile:13613264222

Product Categories
Home > 供应产品 > Mining Shielded Control Cable MKVVP
Mining Shielded Control Cable MKVVP
品牌: Yin Shun
Core material: Oxygen-Free Copper Wire
Insulating material: Polyvinyl Chloride (PVC)
Protective sleeve material: Polyvinyl Chloride (PVC)
单价: 1.00/Rice
最小起订Quantity: 1 Rice
供货总Quantity: 1 Rice
有效期至: 长期有效
最后更新: 2024-07-23 08:53
 
详细Info

Mineral-Use Shielded Control Cable MKVVP

Model

Name

Specs

Usage

MKVV

Copper-core polyethylene insulated PVC sheathed flame-retardant mining control cable

(2-14)*(4-6)

(2-61)*(0.75-2.5)

Laid indoors, within cables, pipes, and other fixed installations

MKVV22

Copper-core polyethylene insulated PVC sheathed steel tape armored flame-retardant mine control cable

(7-61)*(0.75-1.5)

(4-14)*(4-6)

Laid indoors, within cables, pipes, and directly buried, capable of withstanding significant mechanical external forces for fixed installations.

MKVV32

Copper-core polyethylene insulated PVC sheathed steel wire armored flame-retardant mining control cable(2-61)*(0.75-2.5)

(4-14)*(4-6)

Laid indoors, within cables, pipelines, buried directly, or hung vertically, capable of withstanding substantial tension for fixed applications.

MKVVP22

Copper-core polyethylene insulated polyvinyl chloride sheathed woven屏蔽 steel tape armored flame-retardant control cable for coal mine use

(4-14)*(4-6)

(4-61)*2.5mm2

Installation in high-magnetic field rooms, cables, pipelines, direct burial, and hanging, capable of withstanding significant tensile forces for fixed applications.

MKVVRP

Coal mine use copper-core polyethylene insulated polyvinyl chloride sheath braided shield flame-retardant control flexible cable

(4-61)*(0.5-2.5)

(4-37)*(1.5-2.5)

Laid in fixed locations such as large magnetic field rooms, cables, pipelines, etc.

MKVV cable, MKVVP cable, MKVVP2 cable, MKVV22 cable, MKVV32 cable, MKVVR cable, MKVVRP cable, MKVVP22 cable, etc., flame-retardant control cables for coal mines, recommended conductor counts: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61 cores

Rated Voltage: 450/750V

2. The length of the cable conductor is permitted to operate at a temperature of 70 degrees Celsius.

3. The laying temperature of the cables should not be below 0 degrees Celsius, with the recommended allowable bending radius.

4. The cable without armor should not be less than 6 times the diameter of the cable's outer sheath.

5. Cables with armor or copper braid shielding should be not less than 12 times the cable's outer diameter.

6. The flexible cable with a shielding structure should be no less than 6 times the diameter of the cable's outer circumference.