ATA-1BThe rotating disk electrode is widely used in modern electroanalytical chemistry and the study of electrode processes and homogeneous chemical reactions. As the rotating disk electrode rotates, it allows the solution to move regularly on the electrode surface (i.e., in a laminar flow), and the thickness of the diffusion layer on the electrode surface varies with the rotational speed. Consequently, it provides a precise decomposition of the convection-diffusion equation.
Rotary Disc ElectrodeA micro-rotary system used for electrochemical instruments, designed for maintaining constant rotational speed and fluid dynamic modulation of the rotating disc. Consisting of a short stainless steel shaft and a set of electrodes with a few millimeter diameter, the concentric electrode system can rotate and modulate highly even under aggressive modulation rates or waveforms.
Rotary Disc ElectrodeIt is controlled by a proportional integral closed-loop circuit driven by a DC servo motor. The electrodes have a small volume and can be quickly interchanged. The device also features an adjustable valve control system for regulating the flow of inert gas used to purify the electrolyte.
Rotary Disc ElectrodeOperates as a standalone unit or can be directly controlled by electrochemical analyzers such as ALS/CHI/XJP, or other equipment. At the start of analysis, the built-in gas control device can clean the sample. Additionally, the glass electrolytic cell is convenient to use, easy to rinse, clean, and replace. Moving and replacing the electrolytic cell is quite simple.
Primary Technical Performance and Specifications
1Equipment is powered on and rotating.30Minutes later, continuous use is available in the following environments:
①Ambient Temperature: 0~40℃
Relative Humidity: ≤80%
Power Supply: 50Hz, 220V ±10%
④ No significant vibration and strong electromagnetic field.
2RPM:
① Speed Setting: 0-9999 rpm
② RPM Range: 50-8,000 RPM
③ Speed Stability: 50-200 rpm; Relative Error <1%
≥200 rpm Relative Error < 0.5%
3Washing and purification time:
① Time Setting: 0-499 seconds
②Time Display Mode: Local Control - Decreasing, Remote Control - Increasing
4Electrode tip radial跳动≤0.05mm; No axial movement
5Insulation resistance between electrode and other parts > 10MΩ
6Results show: 1602 fully automatic real-time display of rotation speed, oxygen removal time, and 9 working states.
7Swivel shaft: Stainless steel
8Motor: 24V, coreless, MAX low inertia DC servo
9Inlet Pressure: 5 psi, Z Large
10Remote, Remote Control: 1 V is equivalent to 1000 rpm; output voltage is directly proportional to speed.
11Remote, Remote-Controlled Level: TTL High-Level Trigger
12No content provided for translation.Dimensions: 210×240×320
13Weight: 7.6 Kg
14Power Consumption: <25W