ZRC-KX-HA-FF46P2-2×2×1.5 Compensating Conductor Cable Application:
Thermocouple compensating conductors and cables with polyvinyl chloride insulation and sheath offer excellent moisture resistance, wear resistance, and flame-retardant properties; heat-resistant compensating conductors and cables with fluoro-plastic insulation and sheath are produced using continuous extrusion technology.
Intrinsically safe explosion-proof temperature measurement systems use thermocouple compensation wires and cables with low capacitance and low inductance structures. In addition to the performance of standard thermocouple compensation wires and cables, they also possess explosion-proof safety features, forming the intrinsic safety thermocouple temperature measurement system.
ZRC-KX-HA-FF46P2-2x2x1.5 Compensation Conductor Cable Basic Model:
1. Model, alloy wire material, and insulation color
Product Model | Socket thermocouple
| Compensating Wire and Cable Alloy Wires | Insulation coloring | ||
Positive electrode | Negative Pole | Positive electrode | Negative pole | ||
SC | S (Platinum Rhodium 10—Platinum)
| SPC (Copper) | SNC (Copper-Nickel) | Red | Green |
RC | RPC (Copper) | RNC (Copper-Nickel) | Red | Green | |
KCA |
K (Nickel-Chromium-Nickel Silicon) | KPCA (Iron) | KNCA (Copper-Nickel) | Red | Blue |
KCB | KPCB (Copper) | KNCB (Copper-Nickel) | Red | Blue | |
KX | KPX (Nickel Chromium) | KNX (Nickel Silicon) | Red | Black | |
NC | N (Nickel Chrome Silicon — Nickel Silicon) | NPC (Iron) | NNC (Copper-Nickel) | Red | Gray |
NX | NPX (Nickel Chrome Silicon) | NNX (Nickel-Silicon) | Red | Gray | |
EX | E(Nickel-Chromium—Nickel-Copper) | EPX (Nickel-Chromium) | ENX (Cupronickel) | Red | Brown |
JX | J (Iron-Copper-Nickel) | JPX (Iron) | JNX (Copper-Nickel) | Red | Purple |
TX | T (Copper—Constantan) | TPX (Copper) | TNX (Tungsten-Nickel) | Red | White |
Note: The model corresponds to the thermocouple grade number. The letter "C" indicates a compensating compensation wire, and "X" indicates an extended compensation wire. SC type compensation wires can be matched with R grade thermocouples.
2. Utilize categorized options and colored sleeves
Use categories | Precision Grade and Mark | Color-coated sleeve | |||
Standard Grade | Precision grade | Standard Grade | Precision grade | intrinsically safe | |
Generally used in G | ――― | S | Black | Ash灰 | Blue |
Heat-resistant H | ――― | S | Black | Huang | Blue |
Specs
Product Name | Nominal Cross-sectional Area | Number of wire cores | Conductor structure | |
Single conductor | Multiconductor (R) | |||
Compensating Wire | 0.2 | 2~19
| 1/0.52 | 7/0.20 |
0.5 | 1/0.80 | 7/0.3 | ||
1.0 | 1/1.13 | 7/0.43 | ||
1.5 | 1/1.37 | 7/0.52 | ||
2.5 | 1/1.76 | 19/0.41 | ||
Thermal electromotive force, tolerance, and reciprocating resistance
Model | Utilize | Conductor Temperature | Thermoelectric Potential | Tolerance ± μv | Thermocouple measuring end temperature | |
Standard Grade | Precision-grade | |||||
SC or RC | G | 0~100 | 645 | ±60(±5.0℃) | ±30(±2.5℃) | 1000 |
H | 0~200 | 1440 | ±60(±5.0℃) | --- | 1000 | |
KCA | G | 0~100 | 4095 | ±100(±2.5℃) | ±60(±1.5℃) | 1000 |
H | 0~200 | 8137 | ±100(±2.5℃) | ±60(±1.5℃) | 900 | |
KCB | G | 0~100 | 4095 | ±100(±2.5℃) | ±60(±1.5℃) | 900 |
KX
| G | -20~100 | 4095 | ±100(±2.5℃) | ±60(±1.5℃) | 900 |
H | -25~200 | 8137 | ±100(±2.5℃) | ±60(±1.5℃) | 900 | |
NC | G | 0~100 | 2774 | ±100(±2.5℃) | ±60(±1.5℃) | 900 |
H | 0~200 | 5912 | ±100(±2.5℃) | ±60(±1.5℃) | 900 | |
NX | G | -20~100 | 2774 | ±100(±2.5℃) | ±60(±1.5℃) | 900 |
H | -25~200 | 5912 | ±100(±2.5℃) | ±60(±1.5℃) | 900 | |
EX | G | -20~100 | 6317 | ±200(±2.5℃) | ±120(±1.5℃) | 500 |
H | -25~200 | 13419 | ±200(±2.5℃) | ±120(±1.5℃) | 500 | |
JX | G | -20~100 | 5268 | ±140(±2.5℃) | ±85(±1.5℃) | 500 |
H | -25~200 | 10777 | ±140(±2.5℃) | ±85(±1.5℃) | 500 | |
TX | G | -20~100 | 4277 | ±60(±1.0℃) | ±30(±0.5℃) | 300 |
H | -25~200 | 9286 | ±90(±1.5℃) | ±48(±0.8℃) | 300 | |

Model | Reciprocating resistance value Ω/m at 20℃ | ||||
0.2mm2 | 0.5 mm2 | 1.0 mm2 | 1.5 mm2 | 2.5 mm2 | |
SC or RC | 2.50 | 0.10 | 0.05 | 0.03 | 0.02 |
KCA | 3.50 | 1.40 | 0.70 | 0.47 | 0.21 |
KCB | 2.60 | 1.04 | 0.52 | 0.35 | 0.21 |
KX | 5.50 | 2.20 | 1.10 | 0.73 | 0.44 |
EX | 6.25 | 2.50 | 1.25 | 0.83 | 0.50 |
JX | 3.25 | 1.30 | 0.65 | 0.43 | 0.26 |
TX | 2.60 | 1.04 | 0.52 | 0.35 | 0.21 |
NC | 3.75 | 1.50 | 0.75 | 0.50 | 0.30 |
NX | 7.15 | 2.86 | 1.43 | 0.95 | 0.57 |

intrinsic safety compensating wire, compensating cable
In addition to the aforementioned performance criteria, the intrinsically safe compensating wire also boasts the following key intrinsically safe performance indicators:
Performance Items | Unit | Index |
Working Capacitance (1kHz) | pF/m | ≤80 |
Capacitance Unbalance (1kHz) | pF/m | ≤1 |
Distributed inductor | μH/m | ≤0.6 |
Electrostatic Induced Voltage (Electrostatic Voltage of 20kV) | V | ≤1 |
Induced voltage due to electromagnetic interference (interference magnetic field 400 A/m) | mV | ≤5 |

ZRC-KX-HA-FF46P2-2x2x1.5 Compensation Conductor Cable Specifications
1. Operating Temperature: Heat Resistant Grade (H):
Polytetrafluoroethylene (F46) at 200°C
Soluble (PFA) 260℃
Silicone rubber, 180°C
Standard Grade (G):
Polyvinyl Chloride (PVC) at 70℃ and 105℃
Low-smoke, halogen-free flame-retardant polyolefin at 70°C
Cross-linked polyethylene at 90°C
2. Very Low Environmental Temperature: Fluoroplastic and Silicone Rubber Sheaths
Fixed Installation -60℃
Non-permanent installation — 20℃
PVC Sheath
Permanent installation - 40℃
Non-fixed laying — 15℃
3. Cable bend radius allowance: Unarmored cable, as small as 6 times the cable outer diameter
Copper tape shielded or steel tape armored cables are very small, only 12 times the diameter of the cable's outer circumference.
Fluoroplastic insulation and sheath are minuscule, being only 10 times the diameter of the cable.