ZRC-KFVRP-10*1.5 High-Temperature Cable Application: Suitable for instrument connections and signal transmission in automatic control systems in metallurgy, power, oil, chemical industries, and mining enterprises under high and low temperatures as well as various harsh environments.

ZRC-KFVRP-10*1.5 High-Temperature Cable Product Features:
Rated Voltage (Uo/U): 450/750V.
2. Long-term allowable working temperature for cable conductors: 200°C.
3. Cable operating temperature range: 0~105°C.
4. Recommended cable bend radius should not be less than 15 times the cable outer diameter.
ZRC-KFVRP-10*1.5 High-Temperature Cable Model and Name:
Model | Name |
KFV | Fluoroplastic insulated, 105C flame-retardant PVC sheathed control cables |
KFVP | Fluoroplastic insulation, 105 flame-retardant PVC sheath, copper wire braid overall shielded control cable |
KFVR | Fluoroplastic insulated, 105 flame-retardant PVC sheathed control flexible cable |
KFVRP | Fluoroplastic insulation, 105 flame-retardant PVC sheath, copper wire braid overall shielded control flexible cable |
ZR-KFV | Fluoroplastic insulated, 105C flame-retardant PVC sheathed control cable |
ZR-KFVP | Fluoroplastic insulation, 105 flame-retardant PVC sheath, copper wire braid overall shielded control cable |
ZR-KFVR | Fluorinated plastic insulation, 105°C flame-retardant PVC sheathed control flexible cable |
ZR-KFVRP | Fluorinated plastic insulation, 105 flame-retardant PVC sheath, copper braid overall shielded control flexible cable |
Model codes and their explanations:
Application: This product is suitable for connection wires of electrical instruments with rated alternating voltage of 450/750V and below, as well as transmission lines for automatic control systems. It boasts excellent properties such as oil resistance, waterproofing, wear resistance, resistance to acids and alkalis, and various corrosive gases, aging resistance, and non-flammability, making it ideal for industries such as metallurgy, electricity, petrochemicals, etc. Standard: The flame-retardant and fire-resistant properties test follows the GB12666-90 standard.
Cable Structure:
Conductor: Multi-strand soft copper core conductor
Insulation: F46 Fluoroplastic Insulation
Shielding: Copper Tape Shield Wrap
Sheath: Flame-retardant Polyvinyl Chloride sheath at 105 degrees
ZRC-KFVRP-10*1.5 High-Temperature Cable Usage Characteristics:
Rated Voltage: U0/U 450/750V
2. Maximum working temperature: Polyallfluorone (F46) insulation not exceeding 200°C, Soluble (PFA) insulation not exceeding 260°C
3. Low environmental temperature: Polyvinyl Chloride (PVC) sheath -40℃ for fixed installation, -15℃ for non-fixed installation; Fluoroplastic and silicone rubber sheath -60℃ for fixed installation, -20℃ for non-fixed installation.
4. Cable installation temperature should not be below 0℃ (fluoroplastic, silicone rubber, and sheathed cables should not be below -25℃).
5. Cable bending radius allowance: 6 times the outer diameter of the unarmored cable for copper tape shielding or 12 times the outer diameter for steel tape armored cables
Fluoroplastic insulated and sheathed cables have a minimum diameter of 8 times the cable's outer diameter.
ZR-KFVRP-450/750-2*1.0 | ZR-KFVRP-450/750-3*1.0 | ZR-KFVRP-450/750-4*1.0 |
ZR-KFVRP-450/750-5*1.0 | ZR-KFVRP-450/750-6*1.0 | ZR-KFVRP-450/750-7*1.0 |
ZR-KFVRP-450/750-8*1.0 | ZR-KFVRP-450/750-10*1.0 | ZR-KFVRP-450/750-12*1.0 |
ZR-KFVRP-450/750-14*1.0 | ZR-KFVRP-450/750-19*1.0 | ZR-KFVRP-450/750-20*1.0 |
ZR-KFVRP-450/750-24*1.0 | ZR-KFVRP-450/750-27*1.0 | ZR-KFVRP-450/750-30*1.0 |