ZR-KFVRP-4*1.5 High-Temperature Cable Application Range: This product is suitable for instrument connections and signal transmission in automatic control systems in metallurgy, power, oil, chemical industries, and mining enterprises, under both high and low temperatures and various harsh environments.
ZR-KFVRP-4*1.5 High-Temperature Cable Product Features:
Rated Voltage (Uo/U): 450/750V.
2. Long-term allowable working temperature for cable conductor: 200°C.
3. Cable operating temperature range: 0~105°C.
4. Recommended cable bend radius should not be less than 15 times the cable outer diameter.

ZR-KFVRP-4*1.5 High Temperature Cable Model, Name:
Model | Name |
KFV | Fluoroplastic insulated, 105°C flame-retardant PVC sheathed control cable |
KFVP | Fluoroplastic insulation, 105 flame-retardant PVC sheath, copper wire braid overall shielded control cable |
KFVR | Fluoroplastic insulated, 105 flame-retardant PVC sheathed control flexible cable |
KFVRP | Fluoroplastic insulation, 105 flame-retardant PVC sheath, copper wire braid overall shielded control flexible cable |
ZR-KFV | Fluoroplastic insulated, 105°C flame-retardant PVC sheathed control cables |
ZR-KFVP | Fluoroplastic insulation, 105 flame-retardant PVC sheath, copper wire braid overall shielded control cable |
ZR-KFVR | Fluoroplastic insulated, 105 flame-retardant PVC sheathed control flexible cable |
ZR-KFVRP | Fluoroplastic insulated, 105 flame-retardant PVC sheathed, copper wire braided overall shielded control flexible cable |
ZR-KFVRP-4*1.5 High-Temperature Cable Model Code Descriptions:
Application: This product is suitable for connecting wires and transmission lines for automatic control systems of electrical instruments with rated alternating voltage of 450/750V and below.
Cable Structure:
Conductor: Multi-strand soft copper core conductor
Insulation: F46 Fluoroplastic Insulation
Shielding: Copper Strip Shielding Wrapping
Sheath: Flame-retardant Polyvinyl Chloride (PVC) sheath at 105 degrees

ZR-KFVRP-4*1.5 High-Temperature Cable Usage Characteristics:
Rated Voltage: U0/U 450/750V
2. Operating Temperature: (F46) Insulation not exceeding 200°C, Soluble Insulation not exceeding 260°C
3. Environmental Temperature: Polyvinyl Chloride Sheath - Fixed installation: -40°C, Non-fixed installation: -15°C; Fluoroplastic and Silicone Rubber Sheath - Fixed installation: -60°C, Non-fixed installation: -20°C
4. Cable installation temperature should not be below 0℃ (fluoroplastic, silicone rubber, and jacketed cables should not be below -25℃).
5. Allowable bend radius: 6 times the outer diameter for unarmored cables, 12 times the outer diameter for cables with steel armor, and 8 times the outer diameter for cables with fluoroplastic insulation and sheath.
ZR-KFVRP-450/750-2*1.5 | ZR-KFVRP-450/750-3*1.5 | ZR-KFVRP-450/750-4*1.5 |
ZR-KFVRP-450/750-5*1.5 | ZR-KFVRP-450/750-6*1.5 | ZR-KFVRP-450/750-7*1.5 |
ZR-KFVRP-450/750-8*1.5 | ZR-KFVRP-450/750-10*1.5 | ZR-KFVRP-450/750-12*1.5 |
ZR-KFVRP-450/750-14*1.5 | ZR-KFVRP-450/750-19*1.5 | ZR-KFVRP-450/750-20*1.5 |
ZR-KFVRP-450/750-24*1.5 | ZR-KFVRP-450/750-27*1.5 | ZR-KFVRP-450/750-30*1.5 |