Features:
Air-cooled industrial chillers are typically integrated units, with the evaporator, compressor, and condenser combined. For chillers with higher power output, it's essential to consider the heat dissipation issue of the condenser fan during operation. When used in an air conditioning plant, the integrated unit requires an exhaust duct to channel the heat expelled by the fan outdoors.
The air-cooled industrial chiller can also be designed as split type, with the condenser placed directly outdoors (referred to as the outdoor unit), and the evaporator and compressor located indoors (referred to as the indoor unit). However, due to the heat absorption issues during the transfer of the refrigerant between the condenser and evaporator, the distance between the indoor and outdoor units is kept within 6 meters. Additionally, the copper pipes transporting the refrigerant require insulation. The power and control cables for the fan can be routed together with the copper pipes, allowing the air conditioning room to simply drill holes and pass through the pipes.
For industrial applications involving small flow and low heat dissipation air-cooled chillers, the integrated unit is typically used directly without the need to consider heat dissipation. For chillers with large flow and heat dissipation, the split type can be chosen.
Air-cooled chillers may experience slight variations in condenser cooling efficiency due to changes in external environmental and seasonal weather conditions. In contrast, water-cooled chillers, utilizing a water tower for heat dissipation, offer more stable performance. However, their drawback is the need for a water tower, which reduces their portability.
1. High-quality compressors serve as the heart of industrial chillers (brand new, imported from Europe, America, or Japan, featuring built-in safety protection, low noise, energy-saving, and durability).
2. The box-type evaporator is equipped with an internal automatic water-filling device, eliminating the need for an expanded water tank during engineering installation, which facilitates installation and maintenance. It is suitable for special occasions with large temperature differences and low flow rates.
3. The finned condenser is crafted from high-efficiency copper tubes with external threads, offering excellent heat dissipation and a compact size. Made using CAD/CAM technology and CNC machining centers, it boasts a tight structure, high reliability, attractive appearance, and energy efficiency.
4. Industrial Chiller System Configuration: Equipped with a single-unit control system, internal compressor dryer filter, expansion valve, maintenance hand valve interface, and other devices, ensuring reliable and safe operation, and facilitating maintenance and repair.
5. The multi-functional operation panel of the industrial chiller is equipped with an ammeter, control system fuse, compressor switch button, pump switch button, electronic temperature controller, various safety protection fault lights, and unit start/run indicator lights. The operation is simple and convenient. The industrial chiller unit configuration includes a single-unit control system, built-in compressor dryer and expansion valve, maintenance hand valve interface, and other devices, ensuring reliable and safe operation of the machine and facilitating maintenance.



Cooling Conditions: chilled water inlet temperature 12°C, chilled water outlet temperature 7°C, ambient temperature 35°C;