Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) was established in 2001, located at No. 2218 Jinnan Road, Development Zone, Heze City. With a registered capital of 50 million yuan and total assets of 500 million yuan, the company has 7 business centers: boiler, deep-freezing vessel, pressure vessel, central air conditioning, engineering installation, international trade, and Internet of Things. It has three factory areas on Jinnan Road, East Yangtze Road, and Bohai Road, covering a total of 200,000 square meters, with the main workshop spanning 83,000 square meters. It currently employs 710 staff, including 247 engineers and technicians, and 82 intermediate-level technicians. In December 2016, it was recognized as a "High-tech Enterprise" by the Science and Technology Department. In June 2021, it was identified as a "Specialized and New Enterprise in Shandong Province" by the Ministry of Industry and Information Technology. In June 2022, it was recognized as a "Gazelle Enterprise in Shandong Province" and in August 2022, as a "Specialized and New Small Giant Enterprise" by the Ministry of Industry and Information Technology.
The safe operation of low-temperature CO2 storage tanks is crucial and primarily includes the following aspects: Design and Manufacturing: The tank's design and construction must comply with relevant standards and regulations to ensure they can withstand working conditions under low temperatures and high pressures. The tank should possess sufficient strength and sealing performance to prevent leaks and ruptures. Safety Valves and Pressure Control: The tank should be equipped with safety valves and pressure control devices to ensure internal pressure remains within safe limits. Safety valves should be regularly inspected and tested to ensure proper functioning. Temperature Control: Effective temperature control is necessary for low-temperature CO2 storage tanks to prevent freezing or embrittlement due to excessively low temperatures. Appropriate insulation materials and equipment should be used to maintain the tank and pipeline temperatures within safe ranges. Leak Detection and Alarm: The tank should be fitted with leak detection devices and alarm systems, along with corresponding monitoring equipment. These devices can promptly detect leaks and trigger alarms, allowing for appropriate measures to be taken. Safe Operation and Training: Operators should receive relevant training to understand the safe operation procedures and standards for low-temperature CO2 storage tanks. Operators should be familiar with the tank's characteristics, operational principles, and emergency response measures. Regular Inspections and Maintenance: Tanks should be regularly inspected and maintained, including visual inspections, corrosion coating maintenance, and leak detection. Regular inspections can help identify potential issues early and implement corresponding repair measures. Emergency Preparedness: Establish an emergency response plan and equip with appropriate fire-fighting and first-aid equipment. Operators should be familiar with emergency procedures and capable of responding swiftly to emergencies. Please note that the above points are general recommendations only, and specific safe operating procedures should be based on the design and usage requirements of the low-temperature CO2 storage tank. It is recommended to refer to relevant safety operation manuals and guidelines before using the tank to ensure operational safety.
The spacing regulations for carbon dioxide storage tanks are typically governed by relevant safety codes and standards, with specific spacing requirements potentially varying due to factors like location, use, and tank capacity. Here are some common spacing rules:
- Small Spacing Between Tanks: Generally, the small spacing between adjacent tanks should comply with relevant safety codes and standards. This spacing ensures that neighboring tanks are not affected in the event of a leak or accident.
- Spacing Between Tanks and Buildings: The spacing between tanks and buildings also needs to meet relevant codes and standards. This spacing ensures that buildings are not affected in case of a tank leak or accident.
- Spacing Between Tanks and Equipment: The spacing between tanks and other equipment (such as pipelines, pumps, etc.) should also adhere to relevant codes and standards. This spacing ensures the proper operation and maintenance of the equipment.
- Safety and Evacuation Routes: Sufficient safety and evacuation routes should be provided around and between tanks for safe personnel evacuation during emergencies.
It should be noted that specific spacing rules may vary by region and industry. Therefore, when installing and using carbon dioxide storage tanks, it is essential to refer to local safety codes and standards and consult with experts to ensure compliance with requirements.
To maintain the stability of CO2 storage tanks, attention should be given to the following details:
- Foundation Design: The tank's foundation design must comply with relevant standards and regulations, ensuring adequate strength and stability. The foundation should consider the tank's weight, pressure, and geological conditions to ensure the tank is securely placed on the foundation.
- Lining and Fastening Devices: Appropriate linings, such as rubber pads or steel plates, should be installed between the tank and foundation to reduce friction and vibration. Additionally, use fastening devices like bolts or welding to secure the tank to the foundation, preventing movement and tilting.
- Site Leveling: The site for tank installation should be kept level, without any significant slopes or unevenness. If there are slopes or uneven areas, adjustments and corrections should be made to ensure the tank's stability.
- Seismic Measures: In areas prone to earthquakes, additional seismic measures are required, such as installing seismic supports and enhancing the tank's seismic resistance to improve stability.
- Regular Inspections: Conduct regular inspections of the tank's fastening devices and connection points to ensure they are intact. Any signs of loosening, wear, or damage should be addressed promptly with repairs or replacements.
- Load Distribution: Uniformly distribute loads above the tank, such as platforms or pipelines, to balance the tank's weight distribution and minimize the impact of uneven loads on stability.
- Safety Distance: The tank should maintain sufficient safety distances from other equipment, buildings, and fire sources to prevent accidental collisions or fires from affecting the tank's stability.
It is important to note that the installation of CO2 storage tanks...
Before using the CO2 storage tank, certain inspection and filling points must be addressed. Here are some common precautions:
- Inspect the tank exterior: Check for any visible damage, corrosion, or leakage signs. Ensure the tank shell is undamaged.
- Check valves and fittings: Verify that the valves and fittings on the tank are securely fastened with no leakage. Ensure their proper operation.
- Inspect the pressure gauge: Ensure the pressure gauge on the tank is functioning correctly and the readings are accurate. Replace or repair if abnormal.
- Check the level indicator: Verify that the level indicator on the tank is working properly and accurately displays the level. Repair or replace if abnormal.
- Inspect the pressure relief device: Check that the pressure relief device (such as the safety valve) on the tank is functioning correctly and the set pressure meets requirements. Repair or replace if abnormal.
- Inspect the filling equipment: Verify that the filling equipment (such as filling pipes, pumps, etc.) is working properly with no leakage or blockage. Ensure the safety and reliability of the filling equipment.
- Filling operation: During the filling process, pay attention to the following points:
- Control the filling speed to avoid too fast or too slow.
- Control the filling pressure to avoid exceeding the tank's rated pressure.
- Monitor the level to ensure proper filling.
- Regularly inspect the filling equipment and valves to ensure their normal operation.
- Safety measures: Adhere to relevant safety regulations and procedures during the filling process. Operators should wear appropriate protective gear, such as static-free clothing, gloves, etc.
- Note that specific inspection and filling points may vary depending on the type of tank and application. Before using the CO2 storage tank, inspect and operate according to relevant specifications and standards, and consult with experts to ensure safety and effectiveness.
Our company highly values technological innovation and research and development, boasting one city-level technical center in Heze City. We have established testing facilities for non-destructive testing, physical and chemical testing, welding testing, hydrostatic testing, etc. We are equipped with over 600 pieces of various instruments and equipment, including CNC machine tools, X-ray flaw detectors, digital ultrasonic flaw detectors, mechanical property testing machines, chemical analyzers, spectrometers, tensile testing machines, plasma welding machines, and more. The key products we have developed, such as welding of temperature and pressure vessels, biomass boiler emissions reduction, and waste heat utilization, have successively been selected for multiple Shandong Provincial Department of Industry and Information Technology scientific and technological innovation projects, Shandong Provincial key projects, and Heze City innovative and excellent projects. We have cumulatively obtained 27 authorized utility model patents, 16 authorized invention patents, participated in drafting 2 standards, 2 industry standards, and registered 15 trademarks. The technical team of our company, in collaboration with Professor Li Yajiang of Shandong University, has developed deep cryogenic container processing technology, utilizing the international plasma arc + filler wire tungsten inert gas arc welding (PAW-GTAW) technology. After the provincial-level scientific and technological achievement evaluation, the technology level has reached an international standard in the field of deep cryogenic container manufacturing. Choose Zhongjie Special Equipment, and let's create brilliance together!