Design Principles of Training Tower: Facilitate duty readiness, military and officer training, enhance team combat effectiveness, and meet the needs of safeguarding modern construction and the safety of people's lives and property. Design Aim of Training Tower: Scientific and practical.
Fire training towers shall meet the following requirements:
One, the training tower should be located at the end of the training ground with a reserved runway, and a sand pit of 1.5 meters in front of the tower.
The training tower should have at least four floors, and in cities with a high number of high-rise buildings, the number of floors can be appropriately increased.
III. The training tower's facade features at least two windows per level, with a width between the windows (and the wall) of 1.0 meter.
Four, the training tower window dimensions are 1.2m x 1.8m, the window must be no less than 0.65m from the tower edge, the window sill width is 0.4m, the sill board thickness is 0.05m (protruding 5cm from the tower wall), the height from each window sill to the floor of that level is 0.8m, the floor height is 3.5m, and an inner staircase with a clear width of no less than 0.7m should be provided, with a handrail tube diameter of no less than 0.042m.
V. Inside each floor of the training tower, a platform of not less than 1.5 meters in width should be set up, and a floor should be provided at the top level.
Six, it is advisable to install an outdoor fire escape ladder in the training tower. The ladder should lead to the top of the tower and ideally be set at a height of 3 meters from the ground, with a width not less than 60 centimeters. Training Tower Description: 1. Mainly composed of (1) simulated windows, (2) floor partitions, (3) rear frames, (4) observation and command platform frames, and the main steel structural frame. Simulated windows are installed at the front of the tower (custom-made with a specified number of floors and windows as needed), and floor partitions (steel plates) are placed between the upper and lower adjacent simulated windows. 2. A rear frame corresponding to the simulated windows is located at the bottom of the tower. 3. The simulated windows, floor partitions, rear frames, and main frame are bolted together. 4. Each floor is connected with a safety staircase. 5. The upper part of the tower is equipped with an observation and command platform.
Section 7: Training towers typically undergo anti-corrosion treatment with spray painting, in military green. Alternatively, camouflage patterns or galvanizing are also available.
Section 8: Our steel structure fire training towers are fully functional, featuring detachable and removable designs, unrestricted by location, terrain, or plot. Made with assembled components, they offer low construction costs and high recyclability, saving expenses and achieving twice the results with half the effort. Welcome orders from all fire departments for our fire training towers.