Cables, wires, compensating wires, heating cables, instruments, meters, switc...
产品Price 12.00/Rice
最小起订Quantity:100 Rice 供货总Quantity: 999999 Rice
Model |
|
Voltage |
0.6/1 kV |
Material |
Tin-plated copper wire, XPLE, PVC, polyolefins, rubber |
Usage |
Marine, crane, lifting, mobile |
Manufacturer |
Anhui Wanbang |
Eligible for sale location |
National |
H0FR Cable Cable Structure: Ambient Temperature (°C) 30 35 40 45 Rated Factor: 0.96 0.91 0.87 0.82 If the total length of cable to be installed exceeds 15 meters, it is necessary to choose a cable with a larger cross-sectional area to ensure that the voltage drop is not excessive, thereby maintaining a sufficiently high welding current level. Size Category Shareholding Sheath thickness mm Maximum Outer Diameter mm Nominal Weight Maximum Cycle Value Maximum Cycle Value Maximum Cycle Value 16 6 513 / 0.20 2.0 10.9 212 135 175 245 25 6 783 / 0.20 2.0 12.5 300 180 230 330 35 6 1107 / 0.20 2.0 14 403 225 290 410 50 6 1566 / 0.20 2.2 16 560 285 370 520 70 6 2214 / 0.20 2.4 18.6 776 355 460 650 95 6 2997 / 0.20 2.6 21.2 1035 430 560 790 120 5 608 / 0.50 2.8 23.1 1300 500 650 910 185 5 925/0.50 3.2 29.0 2050 660 850 1200 Loading Current Values(amperes) Nominal Cross-sectional Area At the following cycle values, the initial loading current value mm2 100 % 85% 60% 30% 16 135 145 175 245 25 180 195 230 330 35 225 245 290 410 50 285 310 370 520 70 355 385 460 650 95 430 470 560 790 120 500 540 650 910 185 660 715 850 1200 Correction Factor Ambient Temperature 30°C 35°C 40°C 45°C 50°C 55°C Correction Factor 0.96 0.91 0.87 0.82 0.76 0.79 Conductor Impedance (ohms/km) and Voltage Drop Nominal Cross Section Area Impedance at 20°C (Tinned type) Voltage Drop (for reference only) V / 100 A / 10 m 20°C 60°C 85°C mm2 ohms/Km V V V 16 1.240 1.240 1.430 1.560 25 0.795 0.795 0.920 0.998 35 0.565 0.565 0.654 0.709 50 0.393 0.393 0.455 0.493 70 0.277 0.277 0.321 0.348 95 0.210 0.210 0.246 0.264 120 0.164 0.164 0.190 0.206 185 0.108 0.108 0.125 0.136


Conductor Material: Tin-plated copper/standard copper, Category 6 as per BS6360 standard, with Category 5 conductors for 120 mm2 and above.
Isolation Strip: Crepe Paper/Polyester Tape
Insulating Materials: Acid and alkali-resistant blend, Ethylene Propylene Rubber (E.P.R.) insulation
Housing Material: Acid and alkali-resistant blend, Chloroprene (C.S.P.) (heat-resistant and flame-retardant)
Sheath Color: Black, Grey, Yellow (Tinned Copper Conductor), Black (Standard Copper Conductor)
The structure above can be used to create soft aluminum conductors.
Application:
These cables are designed for high flexibility and are primarily used for secondary connections of automatic or hand-held arc welder electrodes. They can also be used in non-welding equipment, such as grounding circuit conductors, flexible trailing cables for power transmission, and busbar connection devices.
Technical Specifications:
Rated Voltage: 100V (in environments where mechanical damage is not tolerable); such cables can operate at 450/700V in control panels and switchgear.
Rated Temperature: -20 to +85°C
Bend Radius: 6 times cable diameter
Rated Parameters:
Here are the rated current values based on an ambient temperature of 25°C; the corresponding rated factors at higher temperatures (as a ratio to the values at 25°C) are as follows:
Cycle Value:
The cycle value size represents the percentage of the entire cycle (5 minutes). The duration of time in a welding operation is continuously changing. Therefore, the cycle value varies between 20% (interrupted or occasional positioning welding) to 100% (automatic welding).
Automated positioning welding up to 100 %.
Semi-automatic positioning welding 30-85%.
Manual positioning welding 30-60%.
Intermittent or occasional positioning welding up to 20%.
mm
mm
Kg / Km
100 %
60%
30%
Due to the influence of ambient temperature, the working temperature of the cables also varies. These cables are designed to operate stably at ambient temperatures ranging from 25 degrees Celsius to 85 degrees Celsius. The correction factors for higher ambient temperatures are as follows:
Direct Current*