Fujian Aotai Automation Equipment Co., Ltd.VIP

盘装仪表、压力仪表、流量仪表、轨装仪表、物位仪表、分析仪表
Enter Shop

AOLU Series Turbulence Flow Meters

平台认证
  • Unit Price

    Negotiable

  • Brand

    -

  • MOQ

Contact
Leave Msg

Platform Service

Supplier Verified



福建澳泰自动化设备有限公司

VIP   数字营销第2年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    -

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0Piece

  • Address:

    FujianFuzhou

  • Delivery:

    3days

  • View More

Description

I. Overview and Working Principle

The AOLU series of intelligent full-tube vortex flowmeters is a new generation of flowmeters independently developed by our company. This instrument utilizes advanced microcomputer technology and new low-power consumption technology, featuring strong functionality, compact structure, simple operation, and convenient use.

This product is a new type of stress-type vortex shedding flow transmitter. The sensor outputs a voltage pulse frequency signal, which is easy to connect with a computer and can produce a 4-20mA standard signal.

Widely applicable in the oil, chemical, metallurgical, electric power, pharmaceutical, textile, and water supply industries, as well as for the measurement and control of water and gas pipelines at natural gas stations.

The vortex flow sensor/transmitter is mounted on the pipeline, while the flow totalizer or computer is installed in the control room and provides power to the vortex flow sensor/transmitter. They are connected using shielded cables.

The circuit section of the split-body vortex shedding flowmeter is separated from the meter body. The circuit section is installed in a location with good environment and easy detection, and it is connected to the meter body with a dedicated cable ≤10m long at the factory.

     

Section II: Structure and Principle

This product is based on the Karman vortex street principle. When a non-streamlined probe (such as a triangular prism) is vertically inserted into the liquid in a pipe, and the flow rate is sufficiently high, alternating vortices are produced downstream of the flow element. As the vortices grow larger, they move away from the downstream of the flow element, forming two rows of vortices, known as a vortex street (as shown in the right figure). This process is called vortex shedding. The frequency of vortex shedding is related to the fluid flow velocity and the width of the cylindrical body, and is linearly related to the fluid velocity within a certain flow rate range, and this relationship is not affected by the fluid's density, viscosity, pressure, or temperature. Due to the pressure pulsations generated on both sides of the cylinder during vortex shedding, the probe body experiences alternating stresses, causing piezoelectric crystal elements embedded within the probe body to produce alternating charges under the alternating stress. The detection amplifier transforms these alternating charges and outputs a pulse signal proportional to the fluid velocity, which is then sent to a totalizer (or the calculation unit of an intelligent meter) for processing, display, or output as a 4-20mA standard current signal.

III. Features

1. Good versatility of medium, capable of measuring liquids and gases

  Liquids: Water, softened water, gasoline, kerosene, diesel, liquefied petroleum gas, liquid ammonia, phosgene, alkanes, alkenes, alcohols, aldehydes, and various other chemical liquids

Gases: Air, Oxygen, Nitrogen, Natural Gas, Liquefied Gas, Ammonia, Chlorine, Alkanes, Alkenes, Hydrocarbons, and various other gases

No moving parts, simple structure, high reliability.

2. The main body and vortex generator are constructed with high-quality stainless steel, ensuring a long service life.

3. The flow parameters of the instrument are unaffected by measurement parameters such as pressure, temperature, density, viscosity, and composition.

4. High instrument accuracy and repeatability; wide measurement range, up to 1:15 or more.

5. Low instrument pressure loss, low operating costs, and significant energy-saving implications.

6. The output signal is linearly related to the flow, featuring pulse signals, analog signals, etc.

7. Employing a new type of piezoelectric crystal signal processing amplifier and unique filtering technology, effectively eliminates interference signals caused by pressure fluctuations and pipeline vibrations, significantly enhancing the flowmeter's anti-interference capability.

外形结构与安装尺寸

Dimensions for Appearance Installation

Installation Dimensions (Unit: mm)

Nominal Bore Size

Body Internal Diameter (D)

Outside Diameter (D1)

Table Length (L)

Height (H)

15

15

39

65

300

20

20

50

65

300

25

25

57

65

300

32

32

65

65

305

40

40

75

65

305

50

50

87

65

310

65

65

109

65

315

80

80

120

65

315

100

100

149

65

325

125

125

175

85

335

150

150

203

85

350

200

200

259

105

375



    


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery FujianFuzhou3dayswithin
Expiry Long Valid
Update 2024-07-24 16:50
Gallery

Fujian Aotai Automation Equipment Co., Ltd.Published byAOLU Series Turbulence Flow MetersGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top