RTTZ Flexible Mineral Insulated Fire Resistant Cable

平台认证
  • Unit Price

    Negotiable

  • Brand

    One Cable East

  • MOQ

Contact
Leave Msg

Platform Service

Supplier Verified



青岛一缆电缆有限公司

VIP   数字营销第2年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    One Cable East

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0Rice

  • Address:

    ShandongQingdao

  • Delivery:

    0Hours

  • View More

Description

Usage:

  1. Power supply for fire equipment in various buildings, fire elevator power supply, etc.

  2. Key Features and Advantages:

  1. Flexibility: Thanks to the mature braiding technology for the cable conductors and the special process-processed copper soft sheath for the jacket, the cable exhibits both resistance to mechanical impact and flexibility for bending. This characteristic helps to avoid the common issues with wiring terminals and delivery lengths that are often encountered when designing and installing rigid mineral insulated cable BTTZ.

  2. Fireproof: Both conductors and sheaths are made of copper, with a melting point of 1080°C. Insulation and other auxiliary materials are made of minerals with a melting point exceeding 1375°C, ensuring compliance with GB12666.6 and BS6387 standards.

  3. Low Smoke: Conducted smoke dispersion tests according to IEC 1034, and smoke density measurement of cables and optical fibers in accordance with GB/T17651.2-1998 under specific conditions. The test transmittance reaches over 80% (standard is 60%).

  4. Halogen-Free: As both the mineral cable insulation and sheath are made of inorganic materials, there is no PVC material commonly used. Therefore, even under fire conditions, no acidic gases are produced. According to the GB/T17650.2-1998 test for gases released when the material from the cable is burned, the pH value can reach above 5.0 (standard requirement: ≥4.3), and the conductivity can reach approximately 1.0 (standard requirement: ≤10.0).

  5. Temperature Resistance: The cable can operate continuously at an environmental temperature of 125℃ and can replace low-smoke, halogen-free flame-retardant cables with a temperature resistance of 125℃. It can also operate for a short period at 1080℃ during emergencies.

  6. Corrosion-resistant: The cable insulation uses inorganic mineral materials, which do not require any additional measures during installation.

  7. High Load Capacity: Compared to cables of the same cross-section, the main cause of cable overload and short-circuit is usually the insulation. Overloaded conductors tend to overheat, causing the insulation to heat up and age, leading to short-circuit. However, the mineral insulated fire-resistant cables use mineral materials with a melting point of 1375°C for insulation, which can inhibit aging or prevent it in the short term. Therefore, they can transmit higher currents and withstand greater overload to some extent.

  8. High mechanical strength: The sheath of YTTW (BTTE) / NG-A, BTLY (BTLE) copper, aluminum, and other metal-clad mineral insulated fire-resistant cables is made of metal with a high melting point, offering high resistance to mechanical impacts under fire conditions. The non-metallic flexible insulated fire-resistant cables BBTRZ, due to the特殊性 of the insulation material, form a honeycomb-like rigid structure within the insulation layer when burning, effectively resisting external mechanical impacts.

  9. Length customizable: As this product series is all flexible mineral insulated fire-resistant cables, they can be coiled onto reels for packaging, which inherently determines the infinite variability of their manufacturing length. Therefore, the factory can supply according to the design length requirements provided by the customer.

  10. Insulation performance stability: Due to the infinite length of the product, installation does not require consideration of insufficient length causing joints. Fewer joints mean higher insulation performance and are less prone to dampness. Traditional BTTZ joints are more susceptible to dampness.


  11. Specs:

  12. 1×1.5~1×630mm²

  13. 2×1.5~2×400mm²

  14. 3×1.5~3×400mm²

  15. 4×1.5~4×400mm²

  16. 5×1.5~1×400mm²

  17. 3×2.5+1×1.5~3×400+1×240mm²

  18. 4×2.5+1×1.5~4×400+1×240mm²

  19. 3×2.5+2×1.5~3×400+2×240mm²

  20. 4×2.5+2×1.5~4×400+2×240mm²

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery ShandongQingdao
Brand One Cable East
Voltage 0.6/1KVV
Core Count 1/2/3/4/5 core (custom made upon request)
Type Flexible mineral insulated fire-resistant cables
Expiry Long Valid
Update 2024-07-26 16:46
Gallery

Qingdao One Cable Co., Ltd.Published byRTTZ Flexible Mineral Insulated Fire Resistant CableGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top