Key Features:
The ultrasonic probe's rotating steel pipe straight-line running method, combined with the through-type eddy current, forms an integrated flaw detection unit with the following advantages:
The ultrasonic and eddy current techniques are combined into one, merging the two flaw detection methods with complementary performance characteristics. This allows for a more effective enhancement in detecting natural defects.
2. Merging the two machines into one reduces the footprint, as well as the number of operators, auxiliary personnel, and transportation steps, significantly enhancing operational efficiency.
3. A sub-machine was reduced in the equipment set, enhancing the equipment's usage efficiency and detection quality, offering a higher cost-performance ratio.
Key Technical Parameters
Inspection Range: Outer Diameter: Φ10mm ~ Φ30mm; Φ19mm ~ Φ51mm
Φ30mm~Φ89mm;Φ89mm~Φ163mm;
2. Wall thickness: (t/D ≤ 0.2)
Length: 3m to 25m
4. Tube rod requirements: Bend radius ≤ 1.5mm/m; diameter tolerance ≤ 1%D; ellipticity ≤ 1.5%D.
5. Tube Rod Surface Condition: Slight oxidation scale and minor roughness are permissible on the surface.
6. Material: Suitable for inspecting seamless tubes made of various materials.
7. Inspection Methods: UTD probe rotation, ETD through inspection, and straight-line forward detection for pipes and rods.
8. Defect Types: Vertical and Horizontal Internal and External Defects
9. Specification Change Adjustment Time < 30min
10. Inspection Speed: 10-30 m/min
11. Operation Method: PLC control, with both manual and automatic operation modes
12. Execution Standards: GB/T5777-2008; GB/T7735-2004
YB/T4082-2000;YB/T4083-2000;
13. Sensitivity to internal and external injuries: ≤4 dB
14. Azimuth Sensitivity: ≤4 dB
15. Pipe End Blind Zone: ≤200mm
16. Operating Frequency: 0.5-15 MHz
17. Repetition Frequency: 4000 Hz (higher frequency per channel)
18. Signal-to-Noise Ratio ≥ 10 dB
19. Reporting Rate: 1%
20. False alarm rate: 2%
21. After 2 consecutive hours of operation: Sensitivity fluctuation ≤ 2 dB; Signal-to-Noise Ratio fluctuation: ≤ 2 dB.