babjehec specializes in LNG tank installations; which brand is the best?
60CubeLNGStorage Tank Technical Specifications:
Container Type: IICategory Structure Type: Horizontal Insulation Method: Vacuum Powder Insulation (Pearlescent Sand)
Please provide the Chinese content you would like translated into American English. Quality: LNG(Liquefied Natural Gas (LNG) Maximum allowable working pressure:0.86Mpa
Design Temperature: Inner Shell:-196℃ Outer Shell:-20-50℃
Work Pressure:0.8Mpa Exterior Shell:-0.1 MPa Design Pressure:0.84Mpa Outer Case:-0.1 MPa
Available Accumulated:60m3 Effective Volume:54m3 Material: Inner ShellS30408 Outer Shell:Q345R
Specification: Inner Liner:?2400×12400×7/8 Outer case:?2900×13140×8/10 Total Length:14929mm
Total Weight:21760kg Laminate Spacing:250mm Inner tube material:S30408 Dimensions?2916×14929mm
Insulation Sandwich Material:TCHP-50Type Pearl Glitter Sand Fill Volume: >30.8m3
Internal Cylinder Pressure Test: Medium: Nitrogen Test Pressure:1.06Mpa
Valves; Low-temperature stainless steel stop valves Sealing Vacuum Degree: ≤5Pa Static Evaporation Rate ≤0.316%/d
Vacuum Insulated Double Skin Leaking Rate ≤2×10-6 Pa.m3/s Vacuum Insulated Sandwich Panel Air Leakage Rate ≤6×10-5 Pa.m3/s
Manufacturing Acceptance Criteria:
GB/T18442.1~18442.6-2011, TSG21~2016"Regulation on Fixed Container Standards"NB/T47042-2014
60m3Horizontal Low-Temperature LNG Storage Tank Technical Parameters
(2)Tank Pipeline Valve Instrument List (Domestic High-Quality Products)
Serial Number | Name Please provide the Chinese content that needs to be translated. | Specs | Quantity | Factory Home |
1 | Low-temperature long shaft stop valve | DN40 | 8Piece | Zhangjiagang Furui Special Equipment Co., Ltd. |
2 | Low-temperature long shaft stop valve | DN25 | 2Piece | Zhangjiagang Furu Special Equipment Co., Ltd. |
3 | Low-temperature long shaft stop valve | DN10 | 1piece | Zhangjiagang Furui Special Equipment Co., Ltd. |
4 | Needle valve | DN10 | 2Piece | Zhangjiagang Fortune Special Equipment Co., Ltd. |
5 | Pipe safety valve | DN4 | 3piece | Zhangjiagang Furui Special Equipment Co., Ltd. |
6 | Three-way valve | DN25 | 1Piece | Zhangjiagang Furui Special Equipment Co., Ltd. |
7 | Safety Valve | DN25 | 2Piece | Zhangjiagang Furu Special Equipment Co., Ltd. |
8 | Level Differential Pressure Gauge | 15KPa | 1Set | Chengdu Lanshi, Sichuan |
9 | Vacuum Valve Assembly | DN30 | 1Set | Chengdu Lanshi, Sichuan |
10 | Oxygen Pressure Gauge | 0-1.6Mpa | 1Piece | Chengdu Tianwei |

LNG storage tanks are essential storage containers for LNG fueling stations, an indispensable part of such facilities. As a professional in the LNG industry, do you truly understand them? Let's delve into a detailed introduction below:
1. Shipment Form
LNG tanks typically come in vertical and horizontal designs. Vertical tanks have the advantage of occupying less land, are easy to use, and reduce the power consumption of submersible pumps due to gravity differences, saving electricity. However, vertical tanks usually exceed 10 meters, which can cause fear among residents, making them unsuitable for urban settings. Horizontal tanks are the most commonly used design today, but their drawback is that they require more land. Additionally, there are safety distance requirements between the tanks and surrounding buildings and facilities, which, according to GB50156, increases the design complexity.
2. Insulating Form
Common insulating forms for LNG tanks include high vacuum multilayer wrapping insulation and pearl sand powder insulation. The latter is more common in practical applications due to its lower cost.
3. Materials
The container is made of high-quality austenitic stainless steel 0Cr18Ni9 sheet or imported 304 steel sheet; the outer container is made of high-quality carbon steel Q345R plate.
4. Security Protection System
The safety protection system consists of tank accessories including: pressure gauges, level indicators, fully enclosed safety valves with one in use and one in reserve at the base, overflow ports, and bursting disks.
5. Filling Forms
LNG tanks can be filled through the top or bottom. Top filling uses cold liquid to liquefy the BOG gas inside the tank. Both methods can be used, and the choice depends on the on-site conditions during the unloading process. It's quite complex and can't be explained in just a few sentences. Those with questions can discuss privately.
6Level Conversion
LNG液位换算质量容积及质量需要按照储罐厂家提供的数据,结合液厂的气质报告数据综合确定。
7Technical Requirements
General technical agreements require the design pressure of LNG tanks.0.8MPA, designed for temperatures down to -196°C, with a daily evaporation rate of no more than 0.20%. The actual working pressure of the tank is generally less than 0..8MPA's, the operating temperature is generally determined by the quality of the liquid, around -100°.
A seemingly simple white large drum, but the waters are deep. How to choose the right storage tank to minimize investment while meeting usage requirements, how to use the tank efficiently to reduce gas station losses and maintenance costs? Welcome to private message for more details.







































