Vertical Axial Flow Pump_SupplyPro Co., Ltd._Vertical Axial Flow Pump, Supply_Yangzhou Marine Pump Co., Ltd._Zhongshang 114 Industry Resources Network
Yangzhou Marine Pump Co., Ltd.

Axial Flow Pumps, Mixed Flow Pumps, and Multi-Size Pump Equipment Supplier

全国咨询热线
0515-88599646  15151066606


Vertical Axial Flow Pump

价      格Negotiable

最小起订0 Piece库存0 Piece

Location
Jiangsu Yancheng
有效期至
长期有效
最后更新
2022-07-11 18:32
View Count
23

Business Card

  • Your company's名称Yangzhou Marine Pump Co., Ltd.
  • 联 系 人贾海亚 (女士)
  • Your company'sPhone0515-88599646
  • Mobile号码15151066606
  • Company AddressYancheng Danyang Private Enterprise Industrial Park (No. 96 Huanghai East Road, City), B Area, Building 9, Unit 2 Factory

买家正在看

  • Vertical Axial Flow Pump Unit

    Negotiable

  • Vertical Axial Flow Pump

    Negotiable

  • Vertical Axial Flow Pump

    Negotiable

  • Vertical Axial Flow Pump

    Negotiable

Product Details

Vertical axial flow pumps are primarily used in the chemical industry, such as electroplating, electroplating equipment, exhaust towers, spray systems, coating, pickling, painting, photovoltaic, and PCB manufacturing and processing industries.


Features

Vertical axial flow pumps are made from various plastic steel materials such as PP+GF, CPVC, and PVDF, which are injection-molded to withstand most chemical substances, acids, and alkalis. Suitable for use in various acid and alkali liquid circulation, cooling, spray washing equipment, waste gas towers, etching machines, and wastewater treatment systems. They can operate without load, without being damaged by rotation. They feature a dry shaft seal design to protect the motor and prevent acidic gases from entering and damaging the bearing. Ideal for circulating and transporting non-electrolytic nickel and various special electroplating solutions. Explosion-proof motors can be used according to environmental requirements.


Pump installation

Inspect the pump shaft and drive shaft for any bending during transportation; if found, straighten them.

2. The installation elevation of the pump must comply with the specifications in the installation drawing to meet the requirements for cavitation margin and start-up.

3. A silt screen should be installed before the water enters the pool to prevent debris from entering the pump. The flow rate of water through the silt screen should not exceed 0.3 meters per second.

4. Before installing the pump, check the blade installation angle to ensure it meets requirements and there is no looseness.

5. After installation, check that all coupling nuts and base bolt nuts are tightened. When tightening the transmission and pump shaft nuts, pay attention to the threading direction.

6. The drive shaft and water pump shaft must be aligned on the same vertical line, with an allowable deviation less than 0.03 millimeters per meter.

7. It is not advisable to install a gate valve on the pump outlet pipeline. If one is present, it must be fully opened before starting up.

9. When using a check valve, install a balancing hammer to counterbalance the weight of the door cover, reduce the resistance to water flow, and make the pump operate more economically.

10. Lubricate the bearings of the transmission mechanism with grease. During maintenance, clean and remove the oil cavity, then refill it with grease, aiming for 1/2 to 2/3 of the cavity to prevent excessive bearing temperature rise during operation. Special attention must be given to ensure that rubber bearings are not exposed to any oils.