Equipment Brief Introduction
The electric hydraulic lifting furnace LYL-20YST incorporates advanced technology and is a self-developed energy-saving and environmentally friendly electric furnace. The equipment boasts an elegant and stylish appearance, an advanced and reasonable structure, and easy operation. The outer shell is made of cold-rolled steel plates, precision machined on CNC machine tools, and finished with a luxurious and beautiful two-color imported epoxy powder electrostatic spraying process. It is highly resistant to high temperatures, corrosion, and fading.
The furnace features uniform temperature distribution, a double-layer heat-insulating body with surface temperatures close to room temperature, and adjustable heating rates. The furnace chamber is constructed using imported high-temperature composite fiber materials and CNC technology, offering strong resistance to thermal shock, excellent resistance to rapid cooling and heating, good corrosion resistance, no collapse, no crystallization, no slagging, no pollution, and a long service life.
The control system employs microcomputer intelligent adjustment technology, featuring PID regulation, full automatic control, self-tuning capabilities, multi-programming, and the ability to create various heating, constant-temperature, and cooling programs. It boasts high temperature control accuracy, energy efficiency, and stability.
The protective device employs independent protection: (over-temperature, over-pressure, over-flow, disconnection, power failure, leakage, short-circuit, etc.).
The hoistable furnace trolley allows for easy removal from the furnace exterior, facilitating material handling and enhancing work efficiency.
Additionally, through our independently developed control software, the electric furnace can be connected to a computer, enabling remote control of a single or multiple furnaces, starting and stopping the furnace, setting temperature control programs, storing temperature control programs, viewing historical curves, and printing historical curves.
Primary Application
This equipment is widely used in universities, research institutions, industrial and mining enterprises, and is an ideal device for experiments and production in powder, electronics, metallurgy, ceramics, sulfur, new glass materials, chemicals, metal sintering, and metal heat treatment.
Company Qualifications & Honors
Quality Management System Certification GB/T 19001:2016/ISO 9001:2015; European UnionCECertification: "Luoyang City Model Enterprise for Civilized and Trustworthy Business Practices"“China Electric Furnace Industry Brand”;“Quality, Service, Reputation - AAA Corporation”The products pass the inspections by testing institutions, and third-party certification can be provided upon request.
Main Functions & Features
1. Energy-efficient and eco-friendly (high-purity composite alumina/ ceramic polycrystalline fiber furnace material, lightweight, low heat retention, energy-saving, on average, operates at half power)
2. Easy replacement and energy-efficient (heating elements are made of resistance wire/silicon carbide rod/silicon molybdenum rod, with long service life and easy replacement)
3. Integrated furnace body and control for easy and flexible operation, saving operational space.
4. High temperature control accuracy (excellent instrument quality, ±1℃ temperature control accuracy) - Instruments can provide third-party inspection certificates.
5. Excellent uniformity of furnace temperature, all-around heating (rational layout, balanced temperature field, no dead corners in the furnace cavity)
6. Microcomputer program-controlled temperature regulation, adjustable heating rate, automatic operation with no need for human supervision
7. Over-temperature, over-pressure, over-flow, leakage, broken coupling, broken rod automatic protection and alarm
8. Electric hydraulic lifting of furnace body ensures smooth and vibration-free operation, facilitating material loading and unloading.
9. Wide Application Range: Universities, research institutions, industrial and mining enterprises, etc., for powder, military industry, electronics, metallurgy, ceramics, glass, machinery, new material development, special materials, refractory materials, building materials, chemicals, metal sintering, and metal heat treatment, etc., for testing and production.
10. Double shell, air convection heat insulation layer
11. Powder-coated housing with a stylish two-tone finish
12. Excellent reputation, numerous clients
13. Excellent value for money, comprehensive after-sales service, 1-year warranty, lifetime on-site maintenance.
Main Technical Parameters
Item | Target Value |
Rated Voltage | 380V |
Design Temperature | 800℃,1000℃,1200℃,1400℃,1600℃,1700℃,1800℃ |
Rising rate | ≤0.1-40℃/min (adjustable) |
Heating Element | Imported Resistance Wire / U-shaped Silicon Carbide Rod / U-shaped Silicon Molybdenum Rod |
Temperature Control Accuracy | ±1℃ |
Temperature control method | Automatic control with LCD touch screen, PID regulation, intelligent microcomputer control, multi-stage programmable temperature control curves, no need for supervision (fully automatic heating, insulation, power off upon door opening) |
Thermometric element | K(0-1300℃)/S(0-1600℃)/B(0-1820℃) |
Furnace lining material | Ceramic Polycrystalline Fiber /Alumina fiber/Alumina Fiber/High-purity alumina fiber/Imported fiber |
Furnace door structure | The furnace door serves as a material platform, with the furnace chamber featuring electric hydraulic lifting for smooth, vibration-free elevation, facilitating loading and unloading. |
Cooling Method | Double-shell construction with air insulation layer |
Surface temperature rise | ≤30℃ |
Random gift | 2 heating rods, 2 rod holders, 1 crucible tongs, 1 pair of heat-resistant gloves, 1 furnace bottom plate, 1 instruction manual and 1 certificate of conformity each. |
Selection Guide
Model | Furnace chamber size (depth x width x height mm/diameter x height mm) | Furnace Volume (L) | Power Voltage (V) | Power (KW) | Temperature Control Accuracy |
LYL-20YST -1 | 300*300*300/300*300 | 27 | 380 | 12 | ±1℃ |
LYL-20YST -2 | 500*500*500/500*500 | 125 | 380 | 25 | ±1℃ |
LYL-20YST -3 | 700*500*500/500*700 | 175 | 380 | 30 | ±1℃ |
LYL-20YST -4 | 800*500*500/500*800 | 200 | 380 | 40 | ±1℃ |
LYL-20YST -5 | 800*800*800/800*800 | 512 | 380 | 90 | ±1℃ |
LYL-20YST -6 | 1200*800*800/800*1200 | 768 | 380 | 100 | ±1℃ |
LYL-20YST -7 | 1000*1000*1000/1000*1000 | 1000 | 380 | 120 | ±1℃ |
LYL-20YST -8 | 1500*1000*1000/1000*1500 | 1500 | 380 | 150 | ±1℃ |
LYL-20YST -9 | 2000*1000*1000/1000*2000 | 2000 | 380 | 180 | ±1℃ |
Temperature Category | 800°F-1800°F available for selection | ||||
Customized Non-Standard | Customized laboratory electric furnaces in various sizes, with both round and square hearths to meet customer requirements. | ||||
Standard Accessories
Name | Image | Quantity | Description | |
High-Temperature Gloves |
| 1Double | Comfortable fit that keeps hands warm; cut-resistant, wear-resistant, and heat-resistant (withstanding up to 350℃; can touch heat for 60 seconds at 100℃, 180 seconds at 100℃); durable and long-lasting. | |
Heating Element | Silicon carbide rod |
| 2Please provide the Chinese content to be translated. | Silicon carbide components, with high usage temperatures, are hard and brittle. After shaping, they are used, such as silicon carbide rods and tubes, which can reach a high heat temperature under dry air conditions.15001000-1200℃ under vacuum, 1350℃ for long-term use in nitrogen atmosphere |
Silicon Molybdenum Rod |
| 2Please provide the Chinese content to be translated. | Silicon molybdenum rods are heated to high temperatures in an oxidizing atmosphere, forming a dense quartz glass film on the surface to prevent further oxidation. Therefore, silicon molybdenum rods possess high-temperature oxidation resistance. In an oxidizing atmosphere, the temperature can reach1800°C, can be used as heating elements for industrial high-temperature furnaces in electronics, ceramics, magnetic materials, glass, metallurgy, refractory materials, etc. | |
Pot tongs |
| 1Please provide the Chinese content you would like translated. | 1. A common chemical instrument, typically used for holding crucibles. Generally made of stainless steel or hard, non-combustible, and non-oxidizable materials. 2. Use clean tongs. 3. When gripping a hot crucible with tongs, preheat the tip of the tongs to prevent the crucible from cracking due to local cooling. After use, place the tongs tip upwards on the table or asbestos mat. 4. After the experiment is complete, clean the crucible tongs and place them in the laboratory equipment cabinet for drying storage. 5. Use the bent section for holding crucibles; use the pointed end for other applications. 6. Crucible tongs are not necessarily used in conjunction with crucibles; they can also be used independently. | |
Optional Accessories List
Combination of furnace temperature control | Touchscreen Gauge | Remote Assistance Module |
Observation window | Exhaust ports and chimneys | Warm fan |
Crucibles, Kiln Shafts, Material Racks | Multiple-material stand | Bottom plate |
Blower | Thermocouple | Centralized Control Industrial Computer |
Foot Wheel | Multi-point temperature measurement | Exhaust Emission Purification Equipment |
Hydraulic Lift (Manual/Electric) | Material table inclined | Vacuum and atmosphere extraction |
Special Note
Quality Assurance | One-year full machine warranty, excluding related consumables (mat boards and heating elements are excluded), lifetime on-site repair service available. |
Factory environment | 1. Indoor Use 2. Environmental temperature: ±5-45℃ range 3. The relative temperature of the surrounding environment shall not exceed 85%. 4. No conductive dust, explosive gases, or gases that can severely damage metals and cause insulation corrosion are present around the stove. |
Safety Protection | 1. When an electric furnace is first used or after a long period of disuse, it must be seasoned; otherwise, the furnace chamber is prone to cracking. 2. Keep clean regularly and check the electrical furnace wiring for good contact on a routine basis. 3. When using the electric furnace, the temperature must not exceed the rated temperature to prevent damage to the heating elements. It is prohibited to pour various flammable liquids or molten metals into the furnace. 4. During the process, the temperature should generally not exceed 300℃ and the rate of temperature increase should be moderate. This is because, when heating up initially, the furnace is cold and requires a significant amount of heat absorption. |
After-sales service | 1. We commit to resolving any technical inquiries from our clients within 1 hour. 2. We promise to issue the test results for equipment returned for repair within 1 working day and complete the repair within 3 working days. Special materials require customization and will be handled accordingly. 3. Within one week after returning the equipment to the customer, conduct a follow-up visit with the user and provide free technical consultation. |
Friendly Reminder | Do not operate the equipment at the rated temperature for extended periods to ensure its normal service life. 2. Carefully count and verify the quantity of goods and accessories upon receipt to avoid any inconvenience caused by shortages or omissions. 3. To extend the lifespan of the instrument, we recommend a heating rate and cooling rate of 10℃/min. Cooling rate should not exceed 5℃/min. 5. This furnace does not have a vacuum-sealed structure; therefore, it is not suitable for introducing flammable and explosive gases. 6. After a period of use, the furnace chamber may develop minor cracks, which is a normal occurrence and will not affect operation. These can be repaired using an alumina coating. |
Common Faults & Troubleshooting
Fault Phenomenon | Fault Cause | Exclusion Methods |
Turn on the control power switch, no power indicator present. | Control circuit, fuse blown, power off | Inspect for short circuits, eliminate if any, then replace the fuse. |
The equipment operates with voltage but no current. | Heating element fracture | Replace heating element |
Instrument PV displays the upper temperature limit of the corresponding type thermocouple. | Thermocouple Short Circuit | Replace Thermocouple |
Power is normal, but the furnace cannot heat up. | Control main circuit damage | Notify maintenance personnel for inspection |