Equipment Brief Introduction
The LYL-16ZLF series high-temperature, high-vacuum furnaces are primarily used for vacuum sintering, quenching, and other processes of hard alloys, magnetic materials, ceramics, and powdered materials. The high-temperature sintering process for materials ensures reliable thermal and insulation properties. The new electrode structure eliminates the issue of electrode leakage in high-temperature furnaces, and the easily damaged parts in the heating system are more convenient for maintenance and replacement.
Primary Application
This equipment is widely used in universities, research institutions, industrial and mining enterprises, and is an ideal device for experiments and production in powder, electronics, metallurgy, ceramics, sulfur, new glass materials, chemicals, metal sintering, and metal heat treatment.
Structural DescriptionStructure)
Carbon steel housing, welded by a pressure vessel factory, ensuring gas tightness of the welds, free from blow holes, cracks, and other leakage points.
2. As required, constructed with a double-layer furnace shell and sealed with O-ring silicone gaskets.
3. The furnace door seal is made with a wire-cutting flange, fitted with an O-ring of silicone, and secured with a handwheel.
4. Furnace chamber is available in square or round shapes, with an optional electrically operated door.
5. The exterior surface of the furnace shell is meticulously polished, presenting a handsome and elegant appearance.
6. Aluminum Oxide Polycrystalline Fiber High-Temperature Furnace Combustion Chamber, Aesthetically Pleasing and Energy-Efficient
7. Use well-known electrical appliances to ensure safe operation.
8. Temperature control and detection are fully implemented
Single Platinum Rhodium (S-Type) ≤ 1500℃
Dual platinum rhodium (Type B) ≤ 1800℃
Vacuum System DescriptionVaccum System)
1. The vacuum system is a diffusion pump unit, which consists of a diffusion pump and a scroll-type Roots vacuum pump. It includes a high vacuum diffusion pump, a water-cooled baffle, a scroll vacuum pump, an electromagnetic vacuum filling valve, a high vacuum pneumatic baffle valve (main valve), a high vacuum pneumatic baffle valve pre-evacuation valve, a high vacuum pneumatic baffle valve (exit valve), an upstream pipeline filling valve, connecting pipes, seals, a composite vacuum gauge, and a power distribution cabinet, etc., forming a pumping system.
2. This unit is not suitable for extracting gases that are corrosive to metals or cause chemical reactions with the pump oil. It can serve as a high vacuum acquisition device for high-tech equipment such as vacuum smelting, vacuum sintering, vacuum heat treatment, vacuum coating, vacuum brazing, and space simulation experimental facilities. The operating environment temperature is 5~40°C, with a relative humidity not exceeding 85%, and the cooling water temperature is 25°C ±5°C.
3. The vacuum level is related to the suction capability of the vacuum pump, the sealing of the chamber, and the degassing amount of the internal materials (such as the inner wall of the furnace, experimental devices, and heat sinks). The ultimate pressure of this unit is 1×10^-3 Pa, the operating pressure is 1×10^-2 Pa, and the suction time is approximately 1 hour.
4. The diffusion pump cannot generate vacuum independently; it must be primed by a preliminary pump to reduce the system pressure to within the required startup pressure of the diffusion pump, which is generally ≤10 Pa.
5. A new water-cooled baffle is installed at the intake of the diffusion pump, effectively preventing the return of oil vapor from the diffusion pump into the vacuum chamber, thus avoiding contamination of the experimental equipment.
6. To prevent the vacuum oil in the preliminary pump from reversing into the diffusion pump cavity upon shutdown, an electromagnetic valve must be installed at the inlet of the preliminary vacuum, automatically isolating the system piping during shutdown.
All valves are actuated pneumatically for easy operation.
8. Upon initiating the vacuum process, this system is equipped with a preliminary evacuation pipeline. The gas being evacuated is directly extracted by the primary pump, bypassing the diffusion pump, to prevent contamination of the diffusion pump by the gas inside the vacuum vessel (moisture, volatiles, impurities). Once the pressure inside the vacuum vessel drops to 10 Pa, close the preliminary evacuation valve and open the baffle valve. The diffusion pump then commences normal evacuation of the vessel.
Corporate Qualifications & Honors
Quality Management System CertificationGB/T19001:2016/ISO 9001:2015; European UnionCECertification; "Luoyang City Model Enterprise for Civilized and Faithful Business Operation"“China Electric Furnace Industry Brand”;“Quality, Service, Reputation - AAA-rated Company”Our products pass inspections by testing institutions, and third-party certification can be provided upon request.
Main Functions & Features
Wide temperature range: 800℃-1800℃ (optional)
2. Vacuum level up to 10^-3 Pa (optional)
3. Energy-efficient and power-saving, environmentally friendly with zero pollution (high-purity composite alumina as furnace material)/Ceramic polycrystalline fiber, lightweight, low heat retention, energy-saving, averaging half-power operation.
4. Easy to replace Energy-saving and time-efficient (heating elements are resistance wire/silicon carbide rod/silicon molybdenum rod, with long service life and easy replacement)
5. Integrated control, easy to operate, and highly user-friendly
6. High temperature control accuracy (high-quality instruments, ± temperature control accuracy)1The thermometer can provide a third-party inspection certificate.
7. Evenly distributed oven temperature (reasonable layout, balanced temperature field, no dead corners in the furnace cavity)
8. Smart temperature control with adjustable heating rate, automatic operation
9. Over-temperature, over-pressure, and over-flow automatic protection
10. Available options for gas flow meters include float flow meters and mass flow meters, enabling manual and automatic control of gas flow, as well as the ability to shut off gas flow.
11. Broad Application Range: Universities, research institutions, industrial and mining enterprises for powder, military industry, electronics, metallurgy, ceramics, glass, machinery, new material development, special materials, refractory materials, building materials, chemicals, metal sintering, and metal heat treatment, etc., for testing and production.
12. Double-shell design, air-insulated, (available with chilled water unit)
13. Exquisite and generous stainless steel shell
14. Excellent reputation, numerous clients
15. Great value for money, comprehensive after-sales service, 1-year warranty, lifetime on-site repair
Main Technical Specifications
Item | Indicator Value |
Rated Voltage | 220V/380V |
Design Temperature | 800℃,1000℃,1200℃,1400℃,1600℃,1700℃,1800℃ |
Rising rate | ≤0.1-40°C/min (adjustable) |
Heating Element | Imported resistive wire/U-shaped silicon-carbide rod/U-shaped silicon-molybdenum rod |
Temperature control accuracy | ±1℃ |
Vacuum level | -0.1 mPa to 6.7 x 10^-3 Pa (optional) |
Flow Meter | Float ball flow meter (optional mass flow meter) |
Temperature Control Method | Intelligent control, PID adjustment, smart microcomputer control, multi-section programmable temperature control curves, unattended operation (fully automatic heating, maintenance, power off upon door opening) |
Thermometric element | K(0-1300℃)/S(0-1600℃)/B(0-1820℃) |
Furnace lining material | Ceramic Polycrystalline Fiber /Alumina fiber/Alumina Silicate Fiber/High-purity aluminum oxide fiber/Imported Fiber |
Appropriate atmosphere | Available for inert protective cooling gases, such as nitrogen, argon, oxygen, and carbon monoxide. Alternatively, atmosphere shutdown can also be selected. |
Cooling Method | Double shell, air insulation layer (optional with cold water unit for water cooling system) |
Surface Temperature Rise | ≤30℃ |
Random gift | 2 heating rods, 2 rod holders, 1 crucible tongs, 1 pair of heat-resistant gloves, 1 instruction manual and 1 certificate of conformity each |
Selection Guide
Model | Furnace chamber dimensions (depth x width x height/diameter x height mm) | Power Voltage (V) | Power (KW) | Temperature Control Accuracy |
LYL-16ZLF-1 | 300*300*300/300*300 | 380 | 12 | ±1℃ |
LYL-16ZLF-2 | 500*500*500/500*500 | 380 | 25 | ±1℃ |
LYL-16ZLF-3 | 700*500*500/500*700 | 380 | 30 | ±1℃ |
LYL-16ZLF-4 | 800*500*500/500*800 | 380 | 40 | ±1℃ |
LYL-16ZLF-5 | 800*800*800/800*800 | 380 | 90 | ±1℃ |
LYL-16ZLF-6 | 1200*800*800/800*1200 | 380 | 100 | ±1℃ |
LYL-16ZLF-7 | 1000*1000*1000/1000*1000 | 380 | 120 | ±1℃ |
LYL-16ZLF-8 | 1500*1000*1000/1000*1500 | 380 | 150 | ±1℃ |
LYL-16ZLF-9 | 2000*1000*1000/*1000*2000 | 380 | 180 | ±1℃ |
Temperature Category | 800°C - 1800°C available for selection | |||
Customized Non-Standard | Customize various sizes of laboratory furnaces to meet customer requirements, with both round and square hearths. | |||
Standard Accessories
Name | Image | Quantity | Description | |
High-Temperature Gloves |
| 1Double | Comfortable and keeps hands warm; cut-resistant, wear-resistant, and heat-resistant (can withstand 350℃ for 60 seconds of contact heat, 100℃ for 180 seconds of contact heat) durable. | |
Heating Element | Silicon carbide rod |
| 2Please provide the Chinese content you would like translated into American English. | Silicon carbide components, with high usage temperatures, are hard and brittle. After molding, they are used, such as silicon carbide rods and tubes, which can reach high heating temperatures under air-dry conditions.1500100-120°C, for use at temperatures up to 1000-1200°C under vacuum, and long-term use at 1350°C in nitrogen atmosphere |
Silicon Molybdenum Rod |
| 2Please provide the Chinese content to be translated. | Silicon molybdenum rods are heated to high temperatures in an oxidizing atmosphere, forming a dense quartz glass film on the surface to prevent further oxidation. Therefore, silicon molybdenum rods exhibit high-temperature oxidation resistance. In an oxidizing atmosphere, the temperature can reach1800℃, can be used as heating elements in high-temperature furnaces for industries such as electronics, ceramics, magnetic materials, glass, metallurgy, and refractory materials. | |
Pot tongs |
| 1Leave it as is. | A common chemical instrument, typically used for holding crucibles. Generally made of stainless steel or hard, non-combustible, and non-oxidizable materials. 2. Use clean tongs. 3. When gripping a hot crucible with tongs, preheat the tip of the tongs to prevent the crucible from cracking due to localized cooling. After use, place the tongs with the tip facing up on the table or a asbestos mat. 4. After the experiment, clean the crucible tongs thoroughly and place them in the lab equipment cabinet for drying storage. 5. Use the bent section for holding crucibles; use the pointed end for other purposes. 6. Crucible tongs are not necessarily used in conjunction with crucibles; they can also be used independently. | |
List of Optional Accessoriesnal Accessories List)
Integrated Control | Touchscreen gauge | Remote Assistance Module |
Observation window | Exhaust holes and chimneys | Warm fan |
Crucibles, molds | Door Stopper | Furnace bottom plate |
Blower | Thermocouple | Centralized Control Industrial Computer |
Foot Wheel | Multi-point temperature measurement | Exhaust Purification Treatment Equipment |
Special Note
Quality Warranty | One-year full machine warranty, excluding related consumables (mat boards and heating elements excluded) with lifetime on-site repair service. |
Factory Environment | 1. Indoor use 2. Environmental temperature: ±5-45℃ range 3. The relative humidity of the surrounding environment should not exceed 85%. 4. No conductive dust, explosive gases, or gases capable of severely damaging metals and insulation around the furnace. |
Safety Protection | 1. When initially using or restarting an electric furnace after a long period of disuse, it is necessary to dry the furnace; otherwise, it may easily cause cracking of the furnace chamber. Keep clean regularly and check the electrical furnace wiring for good contact. 3. When using the electric furnace, the temperature must not exceed the rated temperature to prevent damage to the heating elements. It is prohibited to pour any flammable liquids or molten metals into the furnace. 4. During the process, the temperature should typically not exceed 300℃ and the heating rate should be moderate, as the furnace is cold at the beginning and requires a significant amount of heat absorption. |
After-Sales Service | 1. We promise to address any technical inquiries from our customers within 1 hour. 2. We promise to provide a test result within 1 working day for equipment returned for repair, complete the repair within 3 working days, and handle special materials on a case-by-case basis. 3. Within one week of returning the equipment to the customer, conduct a follow-up visit with the user and provide free technical consultation. |
Friendly Reminder | Do not operate the equipment at the rated temperature for extended periods to ensure its normal service life. 2. Carefully count and verify the quantity of goods and accessories upon receipt to avoid any inconvenience caused by under shipments or missing items. 3. To extend the service life of the instrument, we recommend a heating rate and cooling rate of 10℃/min. 4. The cooling rate should not exceed 5°C/min. 5. This furnace does not have a vacuum-sealed structure; therefore, it is not suitable for introducing flammable or explosive gases. 6. After some use, the furnace chamber may develop minor cracks, which is a normal occurrence and will not affect operation. It can be repaired with an alumina coating. |
Common Faults and Troubleshooting
Fault Phenomenon | Fault Cause | Exclusion Method |
Turn on the control power switch, no power indicator is displayed. | Control circuit, fuse blown, power outage | Check for shorts and replace the fuse after elimination |
Equipment operates with voltage but no current. | Heating element fracture | Replace heating element |
Instrument PV display the upper temperature limit of the corresponding type thermocouple | Thermocouple short circuit | Replace thermocouple |
Power supply is normal, but the furnace cannot heat up. | Control main line damage | Notify maintenance personnel for inspection. |