Important Considerations for Installing Self-Relieving Steam Pressure Reducing Valves_News Center Co., Ltd._Hangzhou Haoweiflu Fluid Control Equipment Co., Ltd.
Current Location:Home>News Center Co., Ltd.>Important Considerations for Installing Self-Relieving Steam Pressure Reducing Valves

    Important Considerations for Installing Self-Relieving Steam Pressure Reducing Valves

    2024-10-30

    ◆ Self-Operated Steam Pressure Reducing Valve Overview:

    The self-contained steam reducing valve operates without external energy, utilizing the energy of the controlled medium as its power source. It introduces an actuating mechanism to control the valve core position, thereby altering the flow area and changing the flow rate, ensuring that the pressure before or after the valve stabilizes to the set value. It features sensitive operation and minimal pressure fluctuations.

    The Self-Operated Steam Pressure Reducing Valves are categorized into two types: B-type for post-pressure regulating after reduction and K-type for pre-pressure regulating before venting. The pressure range is from 15 to 3000 Kpa, compatible with various detection and actuating mechanisms. They are widely used in the automatic control of pressure reduction and stabilization in steam pipeline equipment.

    ◆ Self-Operated Steam Pressure Reducing Valve: Parameter Description
    Valve Component Features: 1. Equipped with a bellows, featuring a pressure-balancing structure with high sensitivity.
    2. Compact structure, reliable performance, and maintenance-free
    3. Standard Modular Design Adopted
    Valve Type: Direct-Flow
    Valve Cover Styles: Standard, Radiator
    Flow Characteristics: Quick-Open
    Port Range: DN15-300 (1/2”-12”)
    Pressure Ratings: PN1.6, 2.5, 4.0, 6.4 MPa (ANSI 150, 300LB)
    Leak Class: ASME B16.104 VI (Soft Seal)
    ASME B16.104 IV (Hard Seal)
    Pipe Connection Methods: Flanged, Welded, Threaded
    Setpoint Deviation: ±8%
    Temperature Range: -30° to 350°


    Actuator Type: Film-type Actuator (Self-contained)
    Piston-type actuator (self-contained)
    Bendable Tube Actuator (Self-contained)

Contact us

Hangzhou Haoweiflu Fluid Control Equipment Co., Ltd.

Service Hotline

13646711811

Company Telephone

13646711811

Address

50 South Chaoyang Road, Dayuan Town, Fuyang District, Hangzhou City, Zhejiang Province


Message Consultation

 Click submit means you agree to《Service terms》《Privacy policy》