Equipment Brief Introduction
The split-type large touch screen controlled hydraulic lifting furnace LYL-16YSML incorporates advanced technology, featuring an independently developed energy-saving and environmentally friendly new electric furnace. The equipment boasts an aesthetically pleasing and modern design, with an advanced and reasonable structure, easy operation, and a shell made of high-quality cold-rolled steel plates. It is precision-machined on CNC machines, finished with a luxurious and beautiful two-color imported epoxy powder electrostatic spraying process. It is resistant to high temperatures, corrosion, and color fading over time.
The furnace features uniform temperature distribution, a double-layer heat-insulating body with surface temperatures close to room temperature, and adjustable heating rates. The furnace chamber is constructed from imported high-temperature composite fiber materials using CNC technology, boasting strong resistance to thermal shock, excellent resistance to rapid cooling and heating, good corrosion resistance, no collapse, no crystallization, no slagging, no pollution, and a long service life.
The control system utilizes microcomputer intelligent adjustment technology, featuring PID regulation, automatic control, self-tuning capabilities, multi-stage program programming, and the ability to create various heating, constant temperature, and cooling programs. It boasts high temperature control accuracy, energy efficiency, and stability.
Protective devices feature independent protection: (over-temperature, over-pressure, over-flow, disconnection, power failure, leakage, short-circuit, etc.).
The liftable furnace with an electrically retractable door allows for easy removal of the furnace body, facilitating the handling of materials and enhancing work efficiency.
Additionally, through our independently developed control software, the electric furnace can be connected to a computer, enabling remote control of a single or multiple furnaces, starting and stopping the furnace, setting temperature control programs, storing temperature control programs, viewing historical curves, and printing historical curves.
Primary Application
This equipment is widely used in universities, research institutes, industrial and mining enterprises, and is an ideal device for experiments and production in powder, electronics, metallurgy, pharmaceuticals, ceramics, sulfur, new glass materials, chemicals, metal sintering, and metal heat treatment.
Corporate Qualifications & Honors
Quality Management System Certification GB/T19001:2016/ISO 9001:2015; EUCECertification: "Luoyang City Model Enterprise for Civilized and Trustworthy Operation"“China Electric Furnace Industry***”;“Quality, Service, Credibility - AAA-rated Company”The products have passed inspections by reputable testing institutions, and third-party certification can be provided upon request.
Main Functions & Features
1. Energy-saving and electricity-efficient, environmentally friendly and pollution-free (high-purity composite alumina/porcelain crystalline fiber furnace material, lightweight, low heat retention, energy-saving, operating at half power on average)
2. Easy replacement with energy saving and time-efficient (heating elements are high-quality resistance wire/silicon carbide rod/silicon molybdenum rod, with long lifespan and easy replacement)
3. Integrated furnace body and control system for convenient and flexible operation, saving space.
4. High temperature control accuracy (excellent instrument quality, ±1℃ temperature control accuracy) - Instruments can provide third-party inspection certificates
5. Excellent uniformity of furnace temperature, four-side heating (rational layout, balanced temperature field, no blind spots in the furnace cavity)
6. Microcomputer programmable temperature control, adjustable heating rate, automatic operation without the need for human supervision
7. Over-temperature, over-pressure, over-flow, leakage, disconnection, and rod breakage automatic protection and alarm
8. Electric hydraulic lifting at the furnace bottom ensures smooth, vibration-free lifting for easy loading and unloading of materials.
9. Wide Application Range: Universities, research institutions, industrial and mining enterprises for powder, military, electronics, metallurgy, pharmaceuticals, ceramics, glass, machinery, new material development, special materials, refractory materials, building materials, chemicals, metal sintering, and metal heat treatment for testing and production.
10. Double-shell structure with air convection insulating layer
11. Electrostatic powder coating on the housing, with a sophisticated two-color design for an elegant and generous appearance
12. Well-regarded with a large customer base
13. Great value for money, comprehensive after-sales service, 1-year warranty, lifetime on-site maintenance.
Main Technical Specifications
Item | Target Value |
Rated Voltage | 380V |
Design Temperature | 800℃,1000℃,1200℃,1400℃,1600℃,1700℃,1800℃ |
Rise rate | ≤0.1-40℃/min (adjustable) |
Heating Element | High-quality Imported Resistance Wire / High-quality U-Type Silicon Carbide Rod / High-quality U-Type Silicon Molybdenum Rod |
Temperature control accuracy | ±1℃ |
Temperature Control Method | Automatic control with LCD touch screen, PID regulation, intelligent microcomputer control, multi-step programmable temperature control curve, unattended operation (full automatic heating, insulation, power off upon door opening) |
Thermometric element | K(0-1300℃)/S(0-1600℃)/B(0-1820℃) |
Furnace chamber material | Ceramic Polycrystalline Fiber /Alumina fiber/Alumina Silicate Fiber/High-purity alumina fiber/Imported Fiber |
Furnace door structure | The furnace door serves as a material platform, featuring a hydraulic lifting mechanism at the bottom for smooth and vibration-free elevation, facilitating loading and unloading. |
Cooling Method | Double-shell structure with air insulation layer |
Surface Temperature Rise | ≤30℃ |
Random gift | 2 heating rods, 2 rod holders, 1 crucible tongs, 1 pair of heat-resistant gloves, 1 furnace bottom plate, 1 instruction manual, 1 certificate of conformity |
Selection Guide
Model | Furnace chamber dimensions (depth x width x height in mm) | Furnace Volume (L) | Power Voltage (V) | Power (KW) | Temperature Control Accuracy |
LYL-16YSML-1 | 300*300*300 | 27 | 380 | 12 | ±1℃ |
LYL-16YSML-2 | 500*500*500 | 125 | 380 | 25 | ±1℃ |
LYL-16YSML-3 | 700*500*500 | 175 | 380 | 30 | ±1℃ |
LYL-16YSML-4 | 800*500*500 | 200 | 380 | 40 | ±1℃ |
LYL-16YSML-5 | 800*800*800 | 512 | 380 | 90 | ±1℃ |
LYL-16YSML-6 | 1200*800*800 | 768 | 380 | 100 | ±1℃ |
LYL-16YSML-7 | 1000*1000*1000 | 1000 | 380 | 120 | ±1℃ |
LYL-16YSML-8 | 1500*1000*1000 | 1500 | 380 | 150 | ±1℃ |
LYL-16YSML-9 | 2000*1000*1000 | 2000 | 380 | 180 | ±1℃ |
Temperature Category | 800°F-1800°F available for selection | ||||
Customized Non-Standard | According to customer requirements, customize different sizes of laboratory furnaces. | ||||
Standard Accessories
Name | Image | Quantity | Description | |
High-Temperature Gloves | | 1Double | Comfortable and keeps hands warm; cut-resistant, wear-resistant, and heat-resistant (can withstand 350℃ for 60 seconds of contact heat, 100℃ for 180 seconds of contact heat) - durable and long-lasting. | |
Heating Element | Silicon carbide rod | | 2Branch | Silicon-carbide components, with high usage temperatures, are hard and brittle. After shaping, they can be used, such as silicon-carbide silicon-carbide rods and silicon-carbide tubes, which can reach a发热 temperature of up to... under dry air conditions.15001000-1200°C under vacuum conditions, 1350°C for long-term use under nitrogen atmosphere |
Silicon Molybdenum Rods | | 2Please provide the Chinese content you would like translated into American English. | Silicon molybdenum rods are heated to high temperatures under an oxidizing atmosphere, forming a dense quartz glass coating on the surface to prevent further oxidation. Therefore, silicon molybdenum rods possess high-temperature oxidation resistance. Under an oxidizing atmosphere, the temperature can reach1800°C, can be used as heating elements for industrial high-temperature furnaces in electronics, ceramics, magnetic materials, glass, metallurgy, refractory materials, etc. | |
Pot tongs | | 1Please provide the Chinese content to be translated. | A common chemical instrument, typically used to hold crucibles. Generally made of stainless steel or hard, non-combustible, and non-oxidizable materials. 2. Use clean tongs. 3. When gripping a hot crucible with tongs, preheat the tip of the tongs to prevent the crucible from cracking due to localized cooling. After use, place the tongs tip upwards on the table or asbestos mat. 4. After the experiment is complete, clean the crucible tongs and place them in the lab equipment cabinet for drying storage. 5. Use the bent portion for holding crucibles; use the pointed tip for other purposes. 6. Crucible tongs are not necessarily used in conjunction with crucibles; they can also be used independently. | |
Optional Accessories List
Furnace temperature control integrated system | Touchscreen Gauge | Remote Assistance Module |
Observation window | Exhaust ports and chimneys | Heating fan |
Crucibles, molds, material racks | Multiple material stand | Bottom plate |
Blower | Thermocouple | Centralized Control Industrial Computer |
Casters | Multi-point temperature measurement | Exhaust purification treatment device |
Hydraulic Lift (Manual/Electric) | Material stand inclined | Vacuum-packing and gas flushing |
Special Note
Quality Assurance | One-year full machine warranty, excluding related consumables (excluding pad boards and heating elements), lifetime on-site repair service available. |
Factory environment | 1. Indoor use 2. Environmental temperature within ±5 to 45°C range. 3. Relative ambient temperature not exceeding 85%. 4. No conductive dust, explosive gases, or gases that can severely damage metals and cause insulation corrosion are present around the stove. |
Safety Protection | 1. When an electric furnace is first used or after a long period of disuse, it must be dried out to prevent the furnace chamber from cracking. Keep clean regularly and inspect the electrical furnace wiring for good contact. 3. When using the electric furnace, the temperature must not exceed the rated temperature to prevent damage to the heating elements. It is prohibited to pour various flammable liquids and molten metals into the furnace. 4. During the working process, the temperature should generally not exceed 300℃ and the heating rate should be moderate, as the furnace is cold at the beginning and requires a significant amount of heat absorption. |
After-sales service | 1. We promise to address any technical inquiries from our clients within 1 hour. 2. We promise to provide a test result within 1 working day for equipment returned for repair, complete the repair within 3 working days, and handle special materials on a case-by-case basis. 3. Within one week of returning the equipment to the customer, conduct a follow-up visit with the user and provide free technical consultation. |
Friendship Reminder | Do not operate the equipment at the rated temperature for extended periods to ensure its normal service life. 2. Carefully count and verify the quantity of goods and accessories upon receipt to avoid any inconvenience caused by shortages or omissions. 3. To extend the service life of the instrument, we recommend a heating rate and cooling rate of 10℃/min. 4. The cooling rate should not exceed 5°C/min. 5. This furnace does not have a vacuum-sealed structure, therefore it is not suitable for introducing flammable or explosive gases. 6. After a period of use, this furnace may develop minor cracks in the hearth, which is a normal occurrence and will not affect operation. These can be repaired using an alumina coating. |
Common Faults and Troubleshooting
Fault Phenomenon | Fault Cause | Exclusion Method |
Power switch on control panel shows no power indicator | Control circuit, fuse blown, power outage | Inspect for short circuits, eliminate if any, then replace the fuse. |
Equipment operates with voltage but no current. | Heating element fracture | Replace heating element |
Instrument PV display the upper temperature limit of the corresponding type of thermocouple. | Thermocouple short circuit | Replace Thermocouple |
Power is normal, but the furnace cannot heat up. | Control main line damage | Notify maintenance personnel for inspection |