Explosion-proof ceiling fan coil

平台认证
  • Unit Price

    Negotiable

  • Brand

    Mei Run

  • MOQ

Contact
Leave Msg

Platform Service

Supplier Verified



南阳美润防爆电气有限公司

VIP   采商通第1年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Mei Run

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0Negotiable

  • Address:

    HenanNanyang

  • Delivery:

    0Hours

  • View More

Description

Explosion-proof fan coil unit applicable locations:

Suitable for Class II, Groups A, B, C explosive gas environments.

2. Suitable for environments with temperature categories T1 to T5.

3. Suitable for flammable and explosive hazardous areas such as extraction, storage, battery manufacturing, warehousing, and refining, particularly for small chemical warehouses, storage facilities, and spaces with limited space.

Explosion-proof ceiling fan coil product features:

The indoor unit features a low-noise design, with thermal insulation and soundproofing materials attached to the inner wall. The indoor fan utilizes a high-quality, efficient centrifugal fan, providing you with a quieter experience.

Energy-saving operation setting function allows the minimum temperature (cooling) and maximum temperature (heating) for a room to be set on the hand-held controller. For instance, if the cooling minimum is set to 25°C, other operators will only be able to set the room temperature above 25°C, preventing waste due to incorrect operation.

Utilizing high-quality compressors, the latest hydrophilic membrane aluminum foil, efficient internally threaded copper tubes, and motors, combined with meticulous system design, the unit boasts superior performance and reliable operation.

Indoor explosion-proof fan coil units (explosion-proof duct fans) and supply/return air ducts are installed within the ceiling, creating a harmonious layout and an elegant production environment for explosion-proof central air conditioning systems, where one can fully enjoy the refined taste.

Remotely controllable from a distance, with power failure memory, weekly scheduling, and fault self-diagnosis capabilities.

Field installation requirements: Explosion-proof fan pipe units (explosion-proof duct fans) can flexibly determine the air supply and return patterns (bottom return or rear return), as well as the condensate discharge direction (left-hand or right-hand). Moreover, they can be matched with various air outlet types to meet your design requirements.

Design and manufacturing of explosion-proof fan pipe sets (explosion-proof duct fans) strictly adhere to national standards.

GB 3836.1-2000 "Electrical Equipment for Explosive Gas Atmospheres – Part 1: General Requirements"

GB 3836.2-2000 Electrical equipment for explosive gas atmospheres — Part 2: Flameproof "d"

GB 3836.3-2000 "Electrical Equipment for Explosive Gas Atmospheres — Part 3: Increased Safety "e""

GB 3836.4-2000 "Electrical Equipment for Explosive Gas Atmospheres – Part 4: Intrinsic Safety 'i'"

GB 3836.9-2006 "Electrical Equipment for Explosive Gas Atmospheres — Part 9: Encapsulation 'm'"

Explosion-proof markings: ExdmII BT4, ExdmII CT4, ExibdmII BT4, ExibdmII CT4

Explosion-proof fan coil technical specifications:

Explosion-proof Fan Pipe Bends (Explosion-proof Duct Fan) Air Inlet Size

Item

Model Number

Supply Air Opening (mm)

Dimensions (Length x Width)

Return Air Grille (mm)

(Length x Width)

BKF(R)2.6H/A2(I)、BKF(R)3.5H/A2(I)

515×100

748×150

BKF(R)5H/A2(I)

738×125

738×207

BKF(R)6.5H/A2(I)、BKF(R)7.5/A2-N3(I)、

BKF(R)7.5/A2-N2(I)、BKF(R)S7.5/A2-N3(I)

918×207

918×207

BKF(R)10/A2-N4(I)、BKF(R)12/A2-N4(I)、BKF(R)14/A2-N4(I)、

BKF(R)D10/A2-N2(I)、BKF(R)12/A2-N2(I)

1155×207

1155×207

BKF(R)12H/A2-N4(I)、BKF(R)14H/A2-N4(I)

1155×207

1278×250

Standard Explosion-Proof Static Pressure Fan Ducting (Explosion-Proof Duct Fan) Specifications Sheet

Indoor unit

Item

 

Model

Cooling capacity

(kW)

Heating capacity

(kW)

Refrigeration Supply

Input Power

(kW)

Heating and conveying

Input Power

(kW)

Power Supply

Airflow

(m3/h)

Motor Transmission

Method

External Static Pressure

(Pa)

Dimensions (mm)

Wide

Deep

High

BKF(R)2.6H/A2(I)

2.6

2.86(3.66)

0.06

0.06(0.86)

220V~50Hz

450

Three-speed Direct Drive

20

913

680

220

BKF(R)3.5H/A2(I)

3.5

3.85(4.65)

0.08

0.08(0.88)

220V~50Hz

520

3-speed direct drive

20

913

680

220

BKF(R)5H/A2(I)

5

5.5(7.0)

0.12

0.12(1.62)

220V~50Hz

700

3-speed direct drive

20

980

736

266

BKF(R)6.5/A2(I)

6.5

7.0(9.1)

0.17

0.17(2.27)

220V~50Hz

1000

Three-speed Direct Drive

25

1159

736

260

BKF(R)7./A2-N3(I)

7.5

8.1(10.2)

0.17

0.17(2.27)

220V~50Hz

1100

3-speed direct drive

30

1159

736

260

BKF(R)7.5/A2-N2(I)

7.5

8.1(10.2)

0.17

0.17(2.27)

220V~50Hz

1100

Three-speed Direct Drive

30

1159

736

260

BKF(R)S7.5/A2-N3(I)

7.5

8.1(10.2)

0.17

0.17(2.27)

220V~50Hz

380V 3N~50Hz

1100

Three-speed Direct Drive

30

1159

736

260

BKF(R)D10/A2-N2(I)

10

11(14.6)

0.25

0.25(3.85)

220V~50Hz

1700

Three-speed Direct Drive

30

1385

736

260

BKF(R)10/A2-N4(I)

10

11(14.6)

0.25

0.25(3.85)

220V~50Hz

380V 3N~50Hz

1500

Three-speed Direct Drive

30

1385

736

260

BKF(R)12/A2-N4(I)

12

13.2(16.8)

0.25

0.25(3.85)

220V~50Hz

380V 3N~50Hz

1700

Three-speed Direct Drive

30

1385

736

260

BKF(R)12H/A2-N4(I)

12

13.2(16.8)

0.45

0.45(4.05)

220V~50Hz

380V 3N~50Hz

2000

Three-speed Direct Drive

100

1463

756

300

BKF(R)12/A2-N2(I)

12

13.2(16.8)

0.5

0.5(4.1)

220V~50Hz

380V 3N~50Hz

2000

Three-speed Direct Drive

30

1385

736

260

BKF(R)14/A2-N4(I)

14

15.4(19.0)

0.5

0.5(4.1)

220V~50Hz

380V 3N~50Hz

2000

Three-speed Direct Drive

30

1385

736

260

BKFR)14H/A2-N4(I)

14

15.4(19.0)

0.5

0.5(4.1)

220V~50Hz

380V 3N~50Hz

2500

Three-speed Direct Drive

100

1463

756

300

Outdoor unit

Item

 

Model

Cooling capacity

(kW)

Heating capacity

(kW)

Refrigeration Supply

Input Power

(kW)

Heating and transmission

Input Power

(kW)

Power Supply

Compressor

Filling quantity

(kg)

Dimensions (mm)

Wide

Deep

High

BKF(R)2.6H/A2(O)

2.6

2.86(3.66)

0.94

0.84

220V~50Hz

Totally enclosed rotor type

0.85

760

320

530

BKF(R)3.5H/A2(O)

3.5

3.85(4.65)

1.32

1.12

220V~50Hz

Totally enclosed rotor type

0.99

760

320

530

BKF(R)5H/A2(O)

5

5.5(7.0)

1.98

1.78

220V~50Hz

Totally enclosed rotor type

1.6

760

320

530

BKF(R)6.5/A2(O)

6.5

7.0(9.1)

2.33

2.13

220V~50Hz

Totally enclosed rotor type

2.2

950

412

700

BKF(R)7.5/A2-N3(O)

7.5

8.1(10.2)

2.68

2.23

220V~50Hz

Totally enclosed radial rotor

2.15

950

412

700

BKF(R)7.5/A2-N2(O)

7.5

8.1(10.2)

2.5

2.28

220V~50Hz

Totally enclosed rotor type

2.3

950

412

840

BKF(R)S7.5/A2-N3(O)

7.5

8.1(10.2)

2.68

2.23

380V 3N~50Hz

Totally enclosed radial type

1.95

950

412

700

BKF(R)D10/A2-N2(O)

10

11(14.6)

3.21

3.11

220V~50Hz

Totally enclosed scroll type

3.3

950

412

1250

BKF(R)10/A2-N4(O)

10

11(14.6)

3.76

3.25

380V 3N~50Hz

Totally enclosed scroll type

2.35

950

412

1250

BKF(R)12/A2-N4(O)

12

13.2(16.8)

4.85

4.65

380V 3N~50Hz

Totally enclosed scroll type

3.0

950

412

1250

BKF(R)12H/A2-N4(O)

12

13.2(16.8)

4.55

3.75

380V 3N~50Hz

Totally enclosed scroll type

3.0

950

412

1250

BKF(R)12/A2-N2(O)

12

13.2(16.8)

3.78

3.65

380V 3N~50Hz

Totally enclosed spiral type

4.1

950

412

1250

BKF(R)14/A2-N4(O)

14

15.4(19.0)

5.12

4.9

380V 3N~50Hz

Totally enclosed scroll type

4.4

950

412

1250

BKF(R)14H/A2-N4(O)

14

15.4(19.0)

5.2

4.7

380V 3N~50Hz

Totally enclosed centrifugal type

4.3

950

412

1250

Note

The energy efficiency rating and power of the above products are measured under standard operating conditions for the standard unit. For non-standard models, please refer to the label.

b. The power in the indoor unit parameter table is "220V~50Hz 380V 3N~50Hz," indicating that the indoor unit for single-cooling models is single-phase power, while heat pumps use three-phase power.

c. Specifications may vary due to product improvements; please refer to the label on the equipment for the specific parameters.

d. Internal mechanism heat input power is: Motor power (Motor + Auxiliary power).

Explosion-proof fan coil unit customization instructions:

1. For specific customization requirements and pricing, please call for details.

2. Different model specifications are available for customization according to customer requirements.

3. Product specifications may vary; please refer to custom parameters for accuracy.

South Defense Meirun specializes in the production of: explosion-proof control boxes, explosion-proof control cabinets, explosion-proof electrical control boxes, explosion-proof electrical equipment control boxes, explosion-proof electrical control units, explosion-proof electrical control cabinets, BXK explosion-proof control boxes, explosion-proof pushbutton control boxes, stainless steel explosion-proof control boxes, explosion-proof power supply control boxes, explosion-proof anti-corrosion control boxes, explosion-proof instrument control boxes, explosion-proof valve control boxes, PLC explosion-proof control boxes, dust explosion-proof control boxes, explosion-proof touch screen control boxes, aluminum alloy explosion-proof control boxes.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery HenanNanyang
Brand Mei Run
Brand Mei Run
Category Explosion-proof Air Conditioner
Is it available for wholesale? Is
Expiry Long Valid
Update 2025-09-17 18:23
Gallery

Nanyang Meirun Explosion-proof Electrical Equipment Co., Ltd.Published byExplosion-proof ceiling fan coilGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top