Explosion-proof fan coil unit applicable locations:
Suitable for Class II, Groups A, B, C explosive gas environments.
2. Suitable for environments with temperature categories T1 to T5.
3. Suitable for flammable and explosive hazardous areas such as extraction, storage, battery manufacturing, warehousing, and refining, particularly for small chemical warehouses, storage facilities, and spaces with limited space.
Explosion-proof ceiling fan coil product features:
The indoor unit features a low-noise design, with thermal insulation and soundproofing materials attached to the inner wall. The indoor fan utilizes a high-quality, efficient centrifugal fan, providing you with a quieter experience.
Energy-saving operation setting function allows the minimum temperature (cooling) and maximum temperature (heating) for a room to be set on the hand-held controller. For instance, if the cooling minimum is set to 25°C, other operators will only be able to set the room temperature above 25°C, preventing waste due to incorrect operation.
Utilizing high-quality compressors, the latest hydrophilic membrane aluminum foil, efficient internally threaded copper tubes, and motors, combined with meticulous system design, the unit boasts superior performance and reliable operation.
Indoor explosion-proof fan coil units (explosion-proof duct fans) and supply/return air ducts are installed within the ceiling, creating a harmonious layout and an elegant production environment for explosion-proof central air conditioning systems, where one can fully enjoy the refined taste.
Remotely controllable from a distance, with power failure memory, weekly scheduling, and fault self-diagnosis capabilities.
Field installation requirements: Explosion-proof fan pipe units (explosion-proof duct fans) can flexibly determine the air supply and return patterns (bottom return or rear return), as well as the condensate discharge direction (left-hand or right-hand). Moreover, they can be matched with various air outlet types to meet your design requirements.
Design and manufacturing of explosion-proof fan pipe sets (explosion-proof duct fans) strictly adhere to national standards.
GB 3836.1-2000 "Electrical Equipment for Explosive Gas Atmospheres – Part 1: General Requirements"
GB 3836.2-2000 Electrical equipment for explosive gas atmospheres — Part 2: Flameproof "d"
GB 3836.3-2000 "Electrical Equipment for Explosive Gas Atmospheres — Part 3: Increased Safety "e""
GB 3836.4-2000 "Electrical Equipment for Explosive Gas Atmospheres – Part 4: Intrinsic Safety 'i'"
GB 3836.9-2006 "Electrical Equipment for Explosive Gas Atmospheres — Part 9: Encapsulation 'm'"
Explosion-proof markings: ExdmII BT4, ExdmII CT4, ExibdmII BT4, ExibdmII CT4
Explosion-proof fan coil technical specifications:
Explosion-proof Fan Pipe Bends (Explosion-proof Duct Fan) Air Inlet Size
Item
Model Number
Supply Air Opening (mm)
Dimensions (Length x Width)
Return Air Grille (mm)
(Length x Width)
BKF(R)2.6H/A2(I)、BKF(R)3.5H/A2(I)
515×100
748×150
BKF(R)5H/A2(I)
738×125
738×207
BKF(R)6.5H/A2(I)、BKF(R)7.5/A2-N3(I)、
BKF(R)7.5/A2-N2(I)、BKF(R)S7.5/A2-N3(I)
918×207
918×207
BKF(R)10/A2-N4(I)、BKF(R)12/A2-N4(I)、BKF(R)14/A2-N4(I)、
BKF(R)D10/A2-N2(I)、BKF(R)12/A2-N2(I)
1155×207
1155×207
BKF(R)12H/A2-N4(I)、BKF(R)14H/A2-N4(I)
1155×207
1278×250
Standard Explosion-Proof Static Pressure Fan Ducting (Explosion-Proof Duct Fan) Specifications Sheet
Indoor unit
Item
Model
Cooling capacity
(kW)
Heating capacity
(kW)
Refrigeration Supply
Input Power
(kW)
Heating and conveying
Input Power
(kW)
Power Supply
Airflow
(m3/h)
Motor Transmission
Method
External Static Pressure
(Pa)
Dimensions (mm)
Wide
Deep
High
BKF(R)2.6H/A2(I)
2.6
2.86(3.66)
0.06
0.06(0.86)
220V~50Hz
450
Three-speed Direct Drive
20
913
680
220
BKF(R)3.5H/A2(I)
3.5
3.85(4.65)
0.08
0.08(0.88)
220V~50Hz
520
3-speed direct drive
20
913
680
220
BKF(R)5H/A2(I)
5
5.5(7.0)
0.12
0.12(1.62)
220V~50Hz
700
3-speed direct drive
20
980
736
266
BKF(R)6.5/A2(I)
6.5
7.0(9.1)
0.17
0.17(2.27)
220V~50Hz
1000
Three-speed Direct Drive
25
1159
736
260
BKF(R)7./A2-N3(I)
7.5
8.1(10.2)
0.17
0.17(2.27)
220V~50Hz
1100
3-speed direct drive
30
1159
736
260
BKF(R)7.5/A2-N2(I)
7.5
8.1(10.2)
0.17
0.17(2.27)
220V~50Hz
1100
Three-speed Direct Drive
30
1159
736
260
BKF(R)S7.5/A2-N3(I)
7.5
8.1(10.2)
0.17
0.17(2.27)
220V~50Hz
380V 3N~50Hz
1100
Three-speed Direct Drive
30
1159
736
260
BKF(R)D10/A2-N2(I)
10
11(14.6)
0.25
0.25(3.85)
220V~50Hz
1700
Three-speed Direct Drive
30
1385
736
260
BKF(R)10/A2-N4(I)
10
11(14.6)
0.25
0.25(3.85)
220V~50Hz
380V 3N~50Hz
1500
Three-speed Direct Drive
30
1385
736
260
BKF(R)12/A2-N4(I)
12
13.2(16.8)
0.25
0.25(3.85)
220V~50Hz
380V 3N~50Hz
1700
Three-speed Direct Drive
30
1385
736
260
BKF(R)12H/A2-N4(I)
12
13.2(16.8)
0.45
0.45(4.05)
220V~50Hz
380V 3N~50Hz
2000
Three-speed Direct Drive
100
1463
756
300
BKF(R)12/A2-N2(I)
12
13.2(16.8)
0.5
0.5(4.1)
220V~50Hz
380V 3N~50Hz
2000
Three-speed Direct Drive
30
1385
736
260
BKF(R)14/A2-N4(I)
14
15.4(19.0)
0.5
0.5(4.1)
220V~50Hz
380V 3N~50Hz
2000
Three-speed Direct Drive
30
1385
736
260
BKFR)14H/A2-N4(I)
14
15.4(19.0)
0.5
0.5(4.1)
220V~50Hz
380V 3N~50Hz
2500
Three-speed Direct Drive
100
1463
756
300
Outdoor unit
Item
Model
Cooling capacity
(kW)
Heating capacity
(kW)
Refrigeration Supply
Input Power
(kW)
Heating and transmission
Input Power
(kW)
Power Supply
Compressor
Filling quantity
(kg)
Dimensions (mm)
Wide
Deep
High
BKF(R)2.6H/A2(O)
2.6
2.86(3.66)
0.94
0.84
220V~50Hz
Totally enclosed rotor type
0.85
760
320
530
BKF(R)3.5H/A2(O)
3.5
3.85(4.65)
1.32
1.12
220V~50Hz
Totally enclosed rotor type
0.99
760
320
530
BKF(R)5H/A2(O)
5
5.5(7.0)
1.98
1.78
220V~50Hz
Totally enclosed rotor type
1.6
760
320
530
BKF(R)6.5/A2(O)
6.5
7.0(9.1)
2.33
2.13
220V~50Hz
Totally enclosed rotor type
2.2
950
412
700
BKF(R)7.5/A2-N3(O)
7.5
8.1(10.2)
2.68
2.23
220V~50Hz
Totally enclosed radial rotor
2.15
950
412
700
BKF(R)7.5/A2-N2(O)
7.5
8.1(10.2)
2.5
2.28
220V~50Hz
Totally enclosed rotor type
2.3
950
412
840
BKF(R)S7.5/A2-N3(O)
7.5
8.1(10.2)
2.68
2.23
380V 3N~50Hz
Totally enclosed radial type
1.95
950
412
700
BKF(R)D10/A2-N2(O)
10
11(14.6)
3.21
3.11
220V~50Hz
Totally enclosed scroll type
3.3
950
412
1250
BKF(R)10/A2-N4(O)
10
11(14.6)
3.76
3.25
380V 3N~50Hz
Totally enclosed scroll type
2.35
950
412
1250
BKF(R)12/A2-N4(O)
12
13.2(16.8)
4.85
4.65
380V 3N~50Hz
Totally enclosed scroll type
3.0
950
412
1250
BKF(R)12H/A2-N4(O)
12
13.2(16.8)
4.55
3.75
380V 3N~50Hz
Totally enclosed scroll type
3.0
950
412
1250
BKF(R)12/A2-N2(O)
12
13.2(16.8)
3.78
3.65
380V 3N~50Hz
Totally enclosed spiral type
4.1
950
412
1250
BKF(R)14/A2-N4(O)
14
15.4(19.0)
5.12
4.9
380V 3N~50Hz
Totally enclosed scroll type
4.4
950
412
1250
BKF(R)14H/A2-N4(O)
14
15.4(19.0)
5.2
4.7
380V 3N~50Hz
Totally enclosed centrifugal type
4.3
950
412
1250
Note
The energy efficiency rating and power of the above products are measured under standard operating conditions for the standard unit. For non-standard models, please refer to the label.
b. The power in the indoor unit parameter table is "220V~50Hz 380V 3N~50Hz," indicating that the indoor unit for single-cooling models is single-phase power, while heat pumps use three-phase power.
c. Specifications may vary due to product improvements; please refer to the label on the equipment for the specific parameters.
d. Internal mechanism heat input power is: Motor power (Motor + Auxiliary power).
Explosion-proof fan coil unit customization instructions:
1. For specific customization requirements and pricing, please call for details.
2. Different model specifications are available for customization according to customer requirements.
3. Product specifications may vary; please refer to custom parameters for accuracy.
South Defense Meirun specializes in the production of: explosion-proof control boxes, explosion-proof control cabinets, explosion-proof electrical control boxes, explosion-proof electrical equipment control boxes, explosion-proof electrical control units, explosion-proof electrical control cabinets, BXK explosion-proof control boxes, explosion-proof pushbutton control boxes, stainless steel explosion-proof control boxes, explosion-proof power supply control boxes, explosion-proof anti-corrosion control boxes, explosion-proof instrument control boxes, explosion-proof valve control boxes, PLC explosion-proof control boxes, dust explosion-proof control boxes, explosion-proof touch screen control boxes, aluminum alloy explosion-proof control boxes.