Explosion-proof Dehumidifier Product Introduction
Explosion-proof dehumidifiers are a type of explosion-proof electrical equipment, primarily used in flammable and explosive environments such as oil refineries, chemical industries, explosive areas, oil depots, and offshore oil platforms. They are designed for air dehumidification, moisture extraction, and drying processes, and must prevent the possibility of explosion caused by electrical circuits in the presence of combustible gases, dust, liquids, and mixed gases during dehumidification.
Portable explosion-proof dehumidifiers must meet national explosion-proof standards to be allowed into the market. Currently, the execution standards for explosion-proof products announced by the state include:
GB3836.1-2000 Electrical Equipment for Explosive Gas Atmospheres — Part 1: General Requirements
GB3836.2-2000 Electrical equipment for explosive gas atmospheres — Part 2: Flameproof "d"
GB3836.4-2000 Electrical equipment for explosive gas atmospheres – Part 2: Intrinsic safety “i” “ib”
GB3836.9-2006 Electrical equipment for explosive gas atmospheres — Part 9: Encapsulation type “m”
GB3836.15-2000 Electrical Equipment for Explosive Gas Atmospheres – Part 15: Electrical Installations in Hazardous Areas (Excluding Coal Mines)
JB/10538-2005 "Explosion-proof Dehumidifier and Air Conditioner"
Explosion-proof dehumidifier operating conditions
Altitude not exceeding 2,000 meters.
2. Environmental temperature between 5~32 degrees Celsius.
3. Relative humidity below 90%;
4. Areas with flammable gases, steam, and air mixtures that could lead to explosions are not to be used.
Explosion-proof Dehumidifier Product Standards
This standard applies to the structural and experimental requirements for explosion-proof dehumidifier equipment in terms of explosion-proof safety.
This standard does not address the safety requirements and performance requirements specified in GB5956 "Safety Requirements for Room Air Conditioning Appliances" and GB7725 "Room Air Conditioners."
Reference Standard
GB3836.1-2000 Electrical equipment for explosive gas atmospheres – Part 1: General requirements
GB3836.2-2000 Electrical equipment for explosive gas atmospheres, Part 2: Ex d GB3836.4-2000 Electrical equipment for explosive gas atmospheres, Part 4: Intrinsic safety "i"
GB3836.9-1990 Intrinsically Safe Electrical Equipment for Explosive Atmospheres, Part 9: Encapsulation Type "m"
GB5956 Safety Requirements for Electrical Equipment of Room Air Conditioners
GB7725 Room Air Conditioner
Explosion-proof Dehumidifier Technical Requirements
The externally purchased dehumidifier prototypes must comply with the GB5956 requirements for the safety of room air conditioning equipment and the requirements of the Room Air Conditioners.
The connection of the dehumidifier's refrigeration system must be by welding.
The explosion-proof junction boxes and other explosion-proof equipment are all equipped with explosion-proof certificates.
All equipment for the complete assembly must have a product quality certificate before use.
All components must be assembled in accordance with manufacturing specifications.
Structural requirements
Fan motors and compressors must be equipped with protectors, limiting device temperatures.
Compressor terminal box, technical requirements for potting-type terminal boxes must comply with Article 4.1 of GB3836.9.
The electrical clearances and creepage distances must comply separately with Chapter 5 and 6 of GB3836.3 and with provisions 4 and 6 of GB3836.4.
Circuit terminals within the explosion-proof junction box and the intrinsically safe circuit terminals must be焊接 and secured with safety terminal caps.
The cable entry device must comply with the requirements of clause 14.2 in GB3836.1.
The conductor cross-sectional area of the intrinsically safe circuit wire should not be less than 0.5mm²; copper stranded wire
The core cross-sectional area of other electrical wires should not be less than 1.5mm²; Copper braided wire
Intrinsically safe and non-intrinsically safe circuits must be separately arranged and securely mounted; the distance between them should not be less than 50mm².
The fan motor must comply with the requirements of GB3836.2-8.3 and GB3836.9-90.
Explosion-proof Dehumidifier Customization Instructions:
1. For specific customization requirements and pricing, please call for details.
2. Different models and specifications are available for customization according to customer requirements.
3. Product specifications may vary; custom specifications apply.
Nanfang Meirun specializes in manufacturing: Industrial explosion-proof air conditioners, oil explosion-proof air conditioners, power explosion-proof air conditioners, explosion-proof air conditioners, explosion-proof vehicle air conditioners, explosion-proof marine air conditioners, dust explosion-proof air conditioners, explosion-proof and corrosion-resistant air conditioners.
Explosion-proof wall-mounted air conditioner, explosion-proof cabinet air conditioner, explosion-proof window air conditioner, explosion-proof skylight air conditioner, explosion-proof portable air conditioner, explosion-proof duct air conditioner, explosion-proof unit air conditioner.