High-temperature Muffle Furnace, High-temperature Car Bottom Furnace, High-temperature Elevating Furnace, Rotating Tube Furnace, High-temperature Vacuum Atmosphere Furnace, High-temperature Melting Block Furnace
价 格Negotiable
最小起订0 piece库存0 piece
High-Temperature Melt Pot with St
Negotiable
High-Temperature Muffle Furnace
Negotiable
Box-type atmosphere furnace
Negotiable
200L Integrated Elevating Oven
Negotiable
1600-degree adjustable罩式炉
Negotiable
Horizontal Muffle Furnace
Negotiable
Hydrogen Reduction Vacuum Atmosph
Negotiable
Volume: 5L, Temperature: 1600-180
Negotiable
High-temperature trolley furnace
Negotiable
Muffle furnace with a maximum tem
Negotiable
Rated Voltage: 380V
Ramp-up Rate: ≤1-40℃/min (user-friendly adjustable)
Temperature Control Accuracy: ±1℃
Temperature Control Method: Utilizes intelligent program instruments (automatically programmable for heating, maintaining, and cooling) with PID regulation.
Dual-circuit protection: Over-temperature, over-pressure, over-flow, coupling failure, power outage, etc.
Customizable: Available for customization
Product Introduction
High-temperature vacuum furnace isEnergy-saving, environmentally friendly, and aesthetically pleasing, the shell is made of cold-rolled steel plate, processed by advanced CNC machine tools. Finished with luxurious and beautiful dual-color imported epoxy powder electrostatic spraying technology, it is resistant to high temperatures and corrosion. Utilizing heating elements, the furnace features a double-layer shell with a forced-air cooling system for rapid temperature drop. It boasts advantages such as balanced thermal field, low surface temperature of the furnace body, fast heating and cooling rate, and energy saving. The furnace chamber is lined with imported composite alumina fiber. Material is constructed through CNC technology, featuring strong resistance to thermal shock, excellent corrosion resistance, no collapse, no crystallization, no spalling, pollution-free, and a long service life. The control system employs microcomputer artificial intelligence adjustment technology, withPIDAdjustable, automatic control, and self-tuning functions, multi-step programing, capable of creating various heating, temperature maintenance, and cooling programs, with high temperature control accuracy; integrated module with silicon-controlled rectifier control and phase-shifting triggering, with a protection system featuring independent over-temperature protection, over-pressure, over-flow, leakage, short-circuit, and other protections. High level of automation, with all indicators reaching advanced levels.
Rated Voltage | 220V/380V |
Control/ Constant Temperature Accuracy | ±1℃ |
Vacuum Degree | Vacuum level-0.1 KPa to 10^-5 Pa available |
Furnace gas | Available for inert gases, oxygen, nitrogen, argon.......et al. |
Temperature Control Method | Microcomputer controlPID tuning, intelligent microcomputer control, multi-section programmable temperature control curves, no need for supervision (fully automatic heating, maintenance, power off upon door opening) |
Heating Element | Imported Resistance Wire/U-Type Silicon Carbon Rod / U-Type Silicon Molybdenum Rod |
Design Temperature | 800℃,1000℃,1200℃,1400℃,1600℃,1700℃,1800℃ |
Rising temperature rate | ≤0.1-40℃ min (adjustable within this range) |
Furnace door structure | Front door side-hinged |
Gas-permeable | Nitrogen, argon, and oxygen gases can be introduced for inert protection. |
Furnace Oxygen Content | Continuous monitoring of the oxygen content inside the furnace chamber, detection ofOxygen content ≤1000 ptm |
Cooling Method | Double-shell structure, air-insulating layer |
Surface temperature rise | ≤30℃ |
Random gift | Heating Rod2 pieces, 2 rods, 1 crucible tongs, 1 pair of refractory gloves, 1 furnace bottom plate, 1 instruction manual and 1 certificate of conformity each |
This equipment is widely used in universities, research institutions, industrial and mining enterprises, etc., for experiments and production in powder, electronics, metallurgy, medicine, ceramics, new materials, chemicals, metal sintering, and metal heat treatment.
Key Technical Parameters
200×150×150 | 220 | 4 | ±1 |
300×200×200 | 380 | 10 | ±1 |
500×300×200 | 380 | 15 | ±1 |
500×300×300 | 380 | 18 | ±1 |
600×500×500 | 380 | 25 | ±1 |
Order Instructions: Furnace chamber dimensions (length)*Wide*HighmmOr circular diameter/Deep**nnTemperature:100-2200℃Vacuum Degree:-0.1KpaPlease provide the Chinese content you would like translated into American English.10-5pa)
Blast furnace dimensions available for customization.!
Special Note
Factory Environment | 1. For indoor use 2. Environmental temperature is within ±5-45℃ range. 3. The relative humidity of the surrounding environment does not exceed 85%. 4. No conductive dust, explosive gases, or gases that can severely damage metals and cause insulation corrosion are present around the stove. |
Safety Protection | 1. When initially using or resuming use after a long period of disuse, an electric furnace must be seasoned to prevent the furnace chamber from cracking. 2. Keep clean regularly and check the electrical furnace wiring for good contact periodically. 3. Do not exceed the rated temperature when using the electric furnace to prevent damaging the heating elements. It is prohibited to pour any flammable liquids or molten metals into the furnace. 4. During the process, the temperature should generally not exceed 300℃ and the rate of temperature increase should be moderate. This is because, at the beginning of the heating, the furnace is cold and requires a significant amount of heat absorption. |
After-sales service | 1. We commit to resolving any technical inquiries from our clients within 1 hour. 2. We promise to provide a test result within 1 working day for equipment returned for repair, complete the repair within 3 working days, and handle special materials as needed. 3. Within one week of returning the equipment to the customer, conduct a follow-up visit with the user and provide free technical consultation. |
Friendly Reminder | Do not operate the equipment for extended periods at the rated temperature to ensure its normal service life. 2. Carefully count and verify the quantity of goods and accessories upon receipt to avoid any inconvenience caused by shortages or omissions. 3. To extend the lifespan of the instrument, we recommend that the heating and cooling rates not exceed 10℃/min. Cooling rate should not exceed 5℃/min. 5. This furnace does not have a vacuum-sealed structure, therefore it is not suitable for introducing flammable or explosive gases. 6. After a period of use, the furnace chamber may develop minor cracks, which is a normal occurrence and will not affect its operation. These can be repaired using an alumina coating. |
Common Faults and Troubleshooting
Equipment operates with voltage but no current. | Heating element fracture | Replace heating element |
InstrumentPV displays the upper temperature limit of the corresponding type of thermocouple. | Thermocouple short circuit | Replace Thermocouple |
InstrumentPV displays the upper temperature limit for the corresponding type of thermocouple. | Thermocouple short circuit | Replace thermocouple |
Power supply is normal, but the furnace cannot heat up. | Control main line damage | NotificationTechnical maintenance personnel conducting inspections |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |

Phone Consultation