High-temperature Muffle Furnace, High-temperature Car Bottom Furnace, High-temperature Elevating Furnace, Rotating Tube Furnace, High-temperature Vacuum Atmosphere Furnace, High-temperature Melting Block Furnace
价 格Negotiable
最小起订0 piece库存0 piece
Hydrogen Reduction Vacuum Atmosph
Negotiable
Muffle furnace with a maximum tem
Negotiable
High-Temperature Melt Pot with St
Negotiable
High-Temperature Melting Slab Fur
Negotiable
High-Temperature Carriage Furnace
Negotiable
1600-degree adjustable罩式炉
Negotiable
Rotary Tube Furnace
Negotiable
PLC-controlled intelligent displa
Negotiable
Fully Automatic High-Temperature
Negotiable
Horizontal Muffle Furnace
Negotiable
Rated Voltage: 380V
Rise Rate: ≤1-40℃/min (user-friendly, adjustable as desired)
Temperature Control Accuracy: ±1℃
Temperature Control Method: Utilizes intelligent program instruments (automatically programmable for heating, maintaining, and cooling) with PID regulation.
Dual circuit protection: Over-temperature, over-pressure, over-flow, disconnection of couplings, power failure, etc.
Customizable: Available for customization
Product Introduction:
Trolley furnaces are widely used in universities, research institutions, industrial and mining enterprises for special experiments and production in powder, military, electronics, metallurgy, pharmaceuticals, ceramics, glass, machinery, new material development, special materials, refractory materials, construction materials, chemicals, metal sintering, and metal heat treatment.
This equipment incorporates advanced technology, featuring a self-developed, energy-saving, and environmentally friendly new electric furnace. It boasts scientifically rational design, attractive appearance, advanced and reasonable structure, simple and convenient operation. The casing is made of high-quality cold-rolled steel plate, precision-machined on CNC lathes, and finished with luxurious and beautiful dual-color imported epoxy powder electrostatic spraying technology. It is resistant to high temperatures, corrosion, and retains its color over time.
The furnace features even temperature distribution, a double-layer heat-insulating body with surface temperatures close to room temperature, and adjustable heating, holding, and cooling rates. The furnace chamber is constructed from imported high-temperature composite fiber materials using CNC technology, offering strong resistance to thermal shock, excellent resistance to rapid cooling and heating, good corrosion resistance, no collapse, no crystallization, no slag, no pollution, and a long service life.
Control system features a touchscreen interface.PLCControl, equipped withPIDAdjustment, automatic control, and self-tuning function.50Sectional programming, capable of setting various heating, constant temperature, and cooling programs with high temperature control accuracy.
Protective devices feature independent protection: (over-temperature, over-pressure, over-flow, coupling failure, power failure, leakage, short circuit, etc.).
Additionally, through our independently developed control software, the electric furnace can be connected to a computer, enabling remote control of a single or multiple furnaces, starting and stopping the furnace, setting temperature control programs, storing temperature control programs, viewing historical curves, and printing historical curves.
Material Station In and Out Function | Manual/Electric/Fully Automatic/PLCFull Control |
Exhaust holes available | Exhaust vent manual/Automatic/Exhaust Heating Treatment(Environmentally friendly) |
Rated Voltage | 380V |
Design Temperature | 800℃,1000℃,1200℃,1400℃,1600℃,1700℃,1800℃ |
Rising temperature rate | ≤0.1-40℃/min (adjustable) |
Heating Element | SuperiorImported Resistance WireSuperiorU-shaped silicon carbide rodSuperiorU-shaped silicon molybdenum rod |
Temperature Control Accuracy | ±1℃ |
Temperature Control Method | Automatic control with LCD touch screen, PID adjustment, intelligent microcomputer control, multi-step programmable temperature control curve, unattended operation (fully automatic heating, temperature maintenance, power off when door is opened) |
Thermometric component | K(0-1300℃)/S(0-1600℃)/B(0-1820℃) |
Furnace chamber material | Ceramic Polycrystalline Fiber / Aluminum Oxide Fiber / Composite Aluminum Oxide Fiber / High Purity Composite Aluminum Oxide Fiber / Imported Fiber |
Furnace door structure | The furnace door and bottom are integrated, with electric/hand operation for easy loading and unloading. |
Cooling Method | Double-shell structure with air insulation layer |
Surface temperature rise | ≤30℃ |
Random gift | 2 heating rods, 2 rod holders, 1 crucible tongs, 1 pair of refractory gloves, 1 furnace bottom plate, 1 instruction manual and 1 certificate of conformity each |
Imported Composite Fiber Materials | 200×150×150 | 220 | 4 | ±1℃ |
Imported composite fiber materials | 300×200×120 | 220 | 6 | ±1℃ |
Imported composite fiber materials | 300×200×200 | 380 | 10 | ±1℃ |
Imported composite fiber materials | 400×250×160 | 380 | 12 | ±1℃ |
Imported composite fiber materials | 400×300×300 | 380 | 14 | ±1℃ |
Imported composite fiber materials | 500×300×200 | 380 | 15 | ±1℃ |
Imported composite fiber materials | 500×300×300 | 380 | 18 | ±1℃ |
Imported composite fiber materials | 500×400×400 | 380 | 20 | ±1℃ |
Imported high-temperature composite fiber materials | 500×500×500 | 380 | 25 | ±1℃ |
Imported High-Temperature Composite Fiber Material | 800×500×500 | 380 | 40 | ±1℃ |
Imported High-Temperature Composite Fiber Material | 1200×800×800 | 380 | 95 | ±1℃ |
Temperature Category:800℃ 1000℃ 1200℃ 1400℃ 1600℃ 1700℃ 1800℃ 2200℃ | ||||
Order Instructions: Furnace chamber dimensions (length)*Wide*HighmmTemperature Requirements100-2200(°F) Please specify any special conditions in advance..
Furnace chamber dimensions available in any size upon customization.!
Special Note
Factory environment | 1Indoor use 2Ambient temperature range: ±5 to 45°C 3Ambient temperature surrounding the equipment should not exceed 85%. 4No conductive dust, explosive gases, or gases that can severely damage metals and insulate corrosion are present around the stove. |
Safety Protection | 1When initially using or restarting an electric furnace after a long period of disuse, kilning is necessary to prevent cracking in the furnace chamber. 2Keep clean regularly and check if the electric furnace wiring is in good contact. 3Do not exceed the rated temperature when using the electric furnace to prevent damaging the heating elements. It is prohibited to pour various flammable liquids or molten metals into the furnace. 4During the process, the temperature should generally not exceed 300℃ and the rate of heating should be moderate, as the furnace is cold at the beginning and requires a significant amount of heat to be absorbed. |
After-sales Service | 1We commit to resolving any technical inquiries from our clients within 1 hour. 2We commit to providing a test result within 1 working day and completing the repair within 3 working days for equipment returned for factory maintenance. Special materials require customization and are handled on a case-by-case basis. 3Within 1 week of returning the equipment to the customer, conduct a follow-up visit with the user and provide free technical consultations. |
Friendly Reminder | 1Do not operate the equipment at the rated temperature for extended periods to ensure its normal service life. 2Carefully count and verify the quantity of goods and accessories upon receipt to avoid any inconvenience caused by shortages or omissions. 3To extend the service life of the instrument, we recommend that the heating and cooling rates not exceed 10℃/min. 4Cooling rate should not exceed 5°C/min. 5This furnace does not have a vacuum-sealed structure, therefore it is not suitable for introducing flammable or explosive gases. 6After a period of use, the furnace chamber may develop minor cracks, which is a normal occurrence and will not affect its operation. These can be repaired using an alumina coating. |
Common Faults and Troubleshooting
Equipment operates with voltage but no current. | Heating element fractured | Replace heating element |
Instrument PV display shows the upper temperature limit of the corresponding type of thermocouple. | Thermocouple Short Circuit | Replace Thermocouple |
PV gauge displays the upper temperature limit of the corresponding thermocouple model | Thermocouple short circuit | Replace Thermocouple |
Power is functioning normally, but the furnace cannot increase in temperature. | Control main circuit damage | Notify the maintenance personnel for inspection. |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |
| Rated Voltage | 200x150x100 | 200 | 4 | ±1°C |

Phone Consultation