Box-type atmosphere furnace_Product Center Co., Ltd._Box-type atmosphere furnace, supply, Machinery and Equipment/Industry Accessories, Machinery and Equipment_Luoyang Xingding Furnace Co., Ltd._Zhongshang 114 Industry Resources Network
Luoyang Xingding Furnace Co., Ltd.

High-temperature Muffle Furnace, High-temperature Car Bottom Furnace, High-temperature Elevating Furnace, Rotating Tube Furnace, High-temperature Vacuum Atmosphere Furnace, High-temperature Melting Block Furnace

全国咨询热线
0379-64226881  18336768158


Box-type atmosphere furnace

价      格Negotiable

最小起订0 Piece库存0 Piece

Location
Henan Luoyang
有效期至
长期有效
最后更新
2024-11-04 09:32
View Count
17

Business Card

  • Your company's名称Luoyang Xingding Furnace Co., Ltd.
  • 联 系 人王秀霞 (先生)
  • Your company'sPhone0379-64226881
  • Mobile号码18336768158
  • Company AddressLuoyang High-tech Industrial Development Zone Sunqitu Tuqiao Valley Industrial Park

买家正在看

  • 200L Integrated Elevating Oven

    Negotiable

  • 1600-degree adjustable罩式炉

    Negotiable

  • 1700°C vacuum atmosphere furnace

    Negotiable

  • Box-type atmosphere furnace

    Negotiable

Product Details

Rated Voltage: 380V

Rising Rate: ≤1-40℃/min (user-friendly, adjustable as desired)

Temperature Control Accuracy: ±1℃

Temperature Control Method: Utilizes intelligent program meters (automatically programmable for heating/cooling/maintenance) with PID regulation.

Dual circuit protection: Over-temperature, over-pressure, over-flow, disconnection, power failure, etc.

Customizable: Available for customization


Product Introduction

High-temperature vacuum furnace isEnergy-saving, environmentally friendly, with an aesthetically pleasing appearance, the housing is made of cold-rolled steel plate, processed by advanced CNC machine tools, and finished with luxurious and beautiful two-color imported epoxy powder electrostatic spraying technology. It is resistant to high temperatures and corrosion. Utilizing heating elements, the furnace features a double-layer shell with a forced-air cooling system for rapid temperature reduction. It boasts advantages such as balanced temperature field, low surface temperature of the furnace body, fast heating and cooling rates, and energy-saving capabilities. The combustion chamber is lined with imported composite alumina fiber. Materials are constructed through CNC processing, featuring strong resistance to thermal shock, excellent corrosion resistance, non-collapsing, non-crystallizing, non-flaking, pollution-free, and a long service life. The control system utilizes microcomputer artificial intelligence adjustment technology, equipped withPIDAdjustable, automatic control, self-tuning functions, multi-programming, capable of programming various heating, holding, and cooling programs, with high temperature control accuracy; integrated module with silicon-controlled rectifier control and phase-shifting triggering, with a protection system that includes independent over-temperature protection, over-pressure, over-flow, leakage, and short-circuit protections. High level of automation, with all indicators reaching advanced levels.


Item   Objective

Indicate  Label   Please provide the Chinese content that needs to be translated into American English.

Rated Voltage

220V/380V

ControlConstant Temperature Accuracy

±1℃

Vacuum Degree

Vacuum Level-0.1 Kpa to 10^-5 Pa available

Furnace Gas

Available for inert gases, oxygen, nitrogen, argon.......et al.

Temperature Control Method

Microcomputer controlPID control, intelligent microcomputer control, multi-section programmable temperature control curves, unattended operation (fully automatic heating, maintenance, power off when door is opened)

Heating Element

Imported resistive wire/U-shaped silicon-carbide rod / U-shaped silicon-molybdenum rod

Design Temperature

800℃,1000℃,1200℃,1400℃,1600℃,1700℃,1800℃

Rising temperature rate

0.1-40℃ min (adjustable within range)

Furnace door structure

Front door side-hinged

Available for gas throughput

Available for introduction of inert protective gases such as nitrogen, argon, and oxygen.

Furnace Oxygen Content

Continuous monitoring of the oxygen content inside the furnace chamber, detection ofOxygen content ≤ 1000 ptm

Cooling method

Double-shell structure, air-insulating layer

Surface Temperature Rise

≤30℃

Random gift

Heating rod2 pieces, 2 rod tools, 1 crucible tongs, 1 pair of heat-resistant gloves, 1 furnace bottom plate, 1 instruction manual, 1 certificate of conformity each

  This equipment is widely used in universities, research institutions, industrial and mining enterprises for experiments and production in powder, electronics, metallurgy, pharmaceuticals, ceramics, new materials, chemicals, metal sintering, and metal heat treatment.



Primary Technical Parameters

Furnace chamber sizemm

Voltage(v)

Power(kw)

Control Precision

200×150×150

220

4

±1

300×200×200

380

10

±1

500×300×200

380

15

±1

500×300×300

380

18

±1

600×500×500

380

25

±1


Order Instructions: Furnace chamber dimensions (length)*Wide*HighmmOr circular diameter/Deep**nnTemperature:100-2200Vacuum Degree:-0.1KpaPlease provide the Chinese content to be translated.10-5pa

Furnace chamber sizes are customizable.!


Special Note

QualityPlease provide the Chinese content to be translated.

One-year full machine warranty, excluding related consumables (excluding pads and heating elements); lifetime on-site repair service. 

Factory environment

1. Indoor use

2. Environmental temperature within ±5-45℃ range.

3. Relative ambient temperature does not exceed 85%.

4. No conductive dust, explosive gases, or gases that can severely damage metals and cause insulation corrosion are present around the stove.

Safety Protection

1. When using an electric furnace for the first time or after a long period of disuse, it is necessary to dry the furnace to prevent cracking of the furnace chamber.

2. Keep the furnace clean regularly and check the electrical connections for good contact.

3. Do not exceed the rated temperature when using the electric furnace to prevent damage to the heating elements. It is strictly prohibited to pour flammable liquids or melted metals into the furnace.

4. During the process, the temperature should generally not exceed 300℃ and the heating rate should be moderate, as the furnace chamber is cold at the beginning and requires a significant amount of heat absorption.

After-sales Service

1. We commit to resolving any technical inquiries from our clients within one hour.

2. We promise to issue the test results within 1 working day for equipment returned for repair, complete the repair within 3 working days, and handle special materials on a case-by-case basis.

3. Within one week after returning the equipment to the customer, conduct a follow-up visit with the user and provide free technical consultation.

Friendly Reminder

Do not operate the equipment at the rated temperature for extended periods to ensure its normal service life.

2. Carefully count and verify the quantity of goods and accessories upon receipt to avoid any inconvenience caused by shortages or omissions.

3. To extend the lifespan of the instrument, we recommend that the heating and cooling rates do not exceed 10℃/min.

Cooling rate should not exceed 5℃/min.

5. This furnace does not have a vacuum-sealed structure, so flammable or explosive gases cannot be introduced.

6. After a period of use, the furnace chamber may develop minor cracks, which is a normal occurrence and will not affect operation. These can be repaired using an alumina coating.


Common Faults and Troubleshooting

Turn on the control power switch, no power indicator displayed.

Control circuit, fuse blown, power off

Check for short circuits, eliminate them if found, and then replace the fuse.

The equipment operates with voltage but no current.

Heating element fracture

Replace heating element

InstrumentPV displays the upper temperature limit of the corresponding type of thermocouple.

Thermocouple Short Circuit

Replace Thermocouple

InstrumentPV displays the upper temperature limit for the corresponding type of thermocouple.

Thermocouple short circuit

Replace Thermocouple

Power supply is normal, but the furnace cannot heat up.

Control main line damage

NotificationTechnical maintenance personnel inspect


Furnace chamber materialFurnace chamber dimensions: mmVoltage VPower in kWTemperature Control Accuracy
Rated Voltage200x150x1002004±1°C
Rated Voltage200x150x1002004±1°C
Rated Voltage200x150x1002004±1°C
Rated Voltage200x150x1002004±1°C
Rated Voltage200x150x1002004±1°C
Rated Voltage200x150x1002004±1°C
Rated Voltage200x150x1002004±1°C


 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
0379-64226881